Sci Total Environ ; 946: 174238, 2024 Oct 10.
Article in English | MEDLINE | ID: mdl-38925381

ABSTRACT

The reliance of the global population on urban aquifers is steadily increasing, and urban aquifers are susceptible to pathogenic contamination through sources such as sewer leakage or urban runoff. However, there is insufficient monitoring of groundwater quality in urban areas. In this study, quantitative polymerase chain reaction (qPCR) was employed to evaluate the presence of human fecal viral indicators and viral pathogens in urban wastewater (n = 13) and groundwater (n = 12) samples from four locations in Barcelona with different degrees of urbanization, as well as in runoff samples (n = 2). Additionally, a target enrichment sequencing (TES) approach was utilized to explore the viral diversity within groundwater and runoff samples, offering insights into viral contamination and potential virus transmission routes in urban areas. Human adenovirus (HAdV) was identified in all wastewater samples, 67 % (8/12) of groundwater samples, and one runoff sample by qPCR indicating human viral fecal contamination. The viral pathogen Norovirus genogroup GI (NoV GI) was detected in wastewater and two winter groundwater samples from highly and medium urbanized areas. NoV genogroup GII (NoV GII), Enterovirus (EV) and SARS-CoV-2 were exclusively detected in wastewater. Human and other vertebrate viruses were detected in groundwater and runoff samples using TES. This study gives insights about the virome present in urban water sources, emphasizing the need for thorough monitoring and deeper understanding to address emerging public health concerns.


Subject(s)
Environmental Monitoring , Groundwater , Groundwater/virology , Humans , Wastewater/virology , Water Microbiology , Cities , Norovirus/isolation & purification , Norovirus/genetics , Feces/virology , Spain , SARS-CoV-2 , Viruses/isolation & purification
2.
Chemosphere ; 313: 137393, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36442679

ABSTRACT

Water treatment and reuse is gaining acceptance as a strategy to fight against water contamination and scarcity, but it usually requires complex treatments to ensure safety. Consequently, the electrochemical advanced processes have emerged as an effective alternative for water remediation. The main objective here is to perform a systematic study that quantifies the efficiency of a laboratory-scale electrochemical system to inactivate bacteria, bacterial spores, protozoa, bacteriophages and viruses in synthetic water, as well as in urban wastewater once treated in a wetland for reuse in irrigation. A Ti|RuO2-based plate and Si|BDD thin-film were comparatively employed as the anode, which was combined with a stainless-steel cathode in an undivided cell operating at 12 V. Despite the low resulting current density (<15 mA/cm2), both anodes demonstrated the production of oxidants in wetland effluent water. The disinfection efficiency was high for the bacteriophage MS2 (T99 in less than 7.1 min) and bacteria (T99 in about 30 min as maximum), but limited for CBV5 and TuV, spores and amoebas (T99 in more than 300 min). MS2 presented a rapid exponential inactivation regardless of the anode and bacteria showed similar sigmoidal curves, whereas human viruses, spores and amoebas resulted in linear profiles. Due the different sensitivity of microorganisms, different models must be considered to predict their inactivation kinetics. On this basis, it can be concluded that evaluating the viral inactivation from inactivation profiles determined for bacteria or some bacteriophages may be misleading. Therefore, neither bacteria nor bacteriophages are suitable models for the disinfection of water containing enteric viruses. The electrochemical treatment added as a final disinfection step enhances the inactivation of microorganisms, which could contribute to safe water reuse for irrigation. Considering the calculated low energy consumption, decentralized water treatment units powered by photovoltaic modules might be a near reality.


Subject(s)
Disinfection , Water Purification , Humans , Disinfection/methods , Bacteria , Oxidation-Reduction , Water Purification/methods , Oxidants
3.
Sci Rep ; 12(1): 16704, 2022 10 06.
Article in English | MEDLINE | ID: mdl-36202959

ABSTRACT

Wastewater-based epidemiology has shown to be an efficient tool to track the circulation of SARS-CoV-2 in communities assisted by wastewater treatment plants (WWTPs). The challenge comes when this approach is employed to help Health authorities in their decision-making. Here, we describe the roadmap for the design and deployment of SARSAIGUA, the Catalan Surveillance Network of SARS-CoV-2 in Sewage. The network monitors, weekly or biweekly, 56 WWTPs evenly distributed across the territory and serving 6 M inhabitants (80% of the Catalan population). Each week, samples from 45 WWTPs are collected, analyzed, results reported to Health authorities, and finally published within less than 72 h in an online dashboard ( https://sarsaigua.icra.cat ). After 20 months of monitoring (July 20-March 22), the standardized viral load (gene copies/day) in all the WWTPs monitored fairly matched the cumulative number of COVID-19 cases along the successive pandemic waves, showing a good fit with the diagnosed cases in the served municipalities (Spearman Rho = 0.69). Here we describe the roadmap of the design and deployment of SARSAIGUA while providing several open-access tools for the management and visualization of the surveillance data.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/epidemiology , Humans , Pandemics , RNA, Viral , Sewage , Wastewater , Wastewater-Based Epidemiological Monitoring
4.
Int J Mol Sci ; 23(19)2022 Oct 02.
Article in English | MEDLINE | ID: mdl-36232983

ABSTRACT

Providing clean drinking water is a great challenge worldwide, especially for low-income countries where the access to safe water is limited. During the last decade, new biotechnological approaches have been explored to improve water management. Among them, the use of antimicrobial nanoparticles for designing innovative centralized and decentralized (point-of-use) water treatment systems for microbial decontamination has received considerable attention. Herein, antimicrobial lignin capped silver nanoparticles (AgLNP) were embedded on residual cork pieces using high-intensity ultrasound coupled with laccase-mediated grafting to obtain biofunctionalized nanomaterial. The developed AgLNP-coated cork proved to be highly efficient to drastically reduce the number of viable Gram-negative Escherichia coli and Gram-positive Staphylococcus aureus in liquid medium. Additionally, the coated-cork was characterized using FTIR-ATR spectroscopy and SEM imaging, and further used as a filter bed in a point-of-use device for water disinfection. The constructed water filtering system significantly reduced the amount of viable E. coli and resistant Bacillus cereus spores from filtered water operating at increasing residence times of 1, 4, 6, 16, 24, and 48 h. Therefore, the presented results prove that the obtained cork-based antimicrobial nanocomposite material could be used as a filtering medium for the development of water filtration system to control pathogen dissemination.


Subject(s)
Anti-Infective Agents , Drinking Water , Metal Nanoparticles , Water Purification , Anti-Bacterial Agents/chemistry , Anti-Bacterial Agents/pharmacology , Disinfection/methods , Escherichia coli , Laccase , Lignin , Metal Nanoparticles/chemistry , Silver/chemistry , Silver/pharmacology , Water Purification/methods
5.
Sci Total Environ ; 829: 154431, 2022 Jul 10.
Article in English | MEDLINE | ID: mdl-35278558

ABSTRACT

Assessing the presence of viruses in large-volume samples involves cumbersome methods that require specialized training and laboratory equipment. In this study, a large volume concentration (LVC) method, based on dead-end ultrafiltration (DEUF) and Wet Foam Elution™ technology, was evaluated in different type of waters and different microorganisms. Its recovery efficiency was evaluated through different techniques (infectivity assays and molecular detection) by spiking different viral surrogates (bacteriophages PhiX174 and MS2 and Coxsackie virus B5 (CVB5) and Escherichia coli (E. coli). Furthermore, the application of a secondary concentration step was evaluated and compared with skimmed milk flocculation. Viruses present in river water, seawater and groundwater samples were concentrated by applying LVC method and a centrifugal ultrafiltration device (CeUF), as a secondary concentration step and quantified with specific qPCR Human adenoviruses (HAdV) and noroviruses (NoVs). MS2 was used as process control, obtaining a mean viral recovery of 22.0 ± 12.47%. The presence of other viruses was also characterized by applying two different next-generation sequencing approaches. LVC coupled to a secondary concentration step based on CeUF allowed to detect naturally occurring viruses such as HAdV and NoVs in different water matrices. Using HAdV as a human fecal indicator, the highest viral pollution was found in river water samples (100% of positive samples), followed by seawater (83.33%) and groundwater samples (66.67%). The LVC method has also proven to be useful as a virus concentration method in the filed since HAdV and NoVs were detected in the river water and groundwater samples concentrated in the field. All in all, LVC method presents high concentration factor and a low limit of detection and provides viral concentrates useful for subsequent molecular analysis such as PCR and massive sequencing.


Subject(s)
Adenoviruses, Human , Norovirus , Escherichia coli , Humans , Real-Time Polymerase Chain Reaction , Ultrafiltration , Water , Water Microbiology
6.
Curr Opin Environ Sci Health ; 24: 100308, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34849439

ABSTRACT

SARS-CoV-2 variants are emerging worldwide, and monitoring them is key in providing early warnings. Here, we summarize the different analytical approaches currently used to study the dissemination of SARS-CoV-2 variants in wastewater and discuss their advantages and disadvantages. We also provide preliminary results of two sensitive and cost-effective approaches: variant-specific reverse transcription-nested PCR assays and a nonvariant-specific amplicon deep sequencing strategy that targets three key regions of the viral spike protein. Next-generation sequencing approaches enable the simultaneous detection of signature mutations of different variants of concern in a single assay and may be the best option to explore the real picture at a particular time. Targeted PCR approaches focused on specific signature mutations will need continuous updating but are sensitive and cost-effective.

7.
Sci Total Environ ; 800: 149562, 2021 Dec 15.
Article in English | MEDLINE | ID: mdl-34391155

ABSTRACT

In the wake of the COVID-19 pandemic, the use of next generation sequencing (NGS) has proved to be an important tool for the genetic characterization of SARS-CoV-2 from clinical samples. The use of different available NGS tools applied to wastewater samples could be the key for an in-depth study of the excreted virome, not only focusing on SARS-CoV-2 circulation and typing, but also to detect other potentially pandemic viruses within the same family. With this aim, 24-hours composite wastewater samples from March and July 2020 were sequenced by applying specific viral NGS as well as target enrichment NGS. The full virome of the analyzed samples was obtained, with human Coronaviridae members (CoV) present in one of those samples after applying the enrichment. One contig was identified as HCoV-OC43 and 8 contigs as SARS-CoV-2. CoVs from other animal hosts were also detected when applying this technique. These contigs were compared with those obtained from contemporary clinical specimens by applying the same target enrichment approach. The results showed that there is a co-circulation in urban areas of human and animal coronaviruses infecting domestic animals and rodents. NGS enrichment-based protocols might be crucial to describe the occurrence and genetic characteristics of SARS-CoV-2 and other Coronaviridae family members within the excreted virome present in wastewater.


Subject(s)
COVID-19 , Pandemics , Animals , High-Throughput Nucleotide Sequencing , Humans , SARS-CoV-2 , Sewage
8.
Foods ; 10(8)2021 Aug 06.
Article in English | MEDLINE | ID: mdl-34441597

ABSTRACT

Fresh fruits and vegetables are susceptible to microbial contamination at every stage of the food production chain, and as a potential source of pathogens, irrigation water quality is a critical factor. Next-generation sequencing (NGS) techniques have been flourishing and expanding to a wide variety of fields. However, their application in food safety remains insufficiently explored, and their sensitivity requires improvement. In this study, quantitative polymerase chain reaction (qPCR) assays showed low but frequent contamination of common circulating viral pathogens, which were found in 46.9% of samples of fresh produce: 6/12 lettuce samples, 4/12 strawberries samples, and 5/8 parsley samples. Furthermore, the application of two different NGS approaches, target enrichment sequencing (TES) for detecting viruses that infect vertebrates and amplicon deep sequencing (ADS), revealed a high diversity of viral pathogens, especially Norovirus (NoV) and Human Papillomavirus (HPV), in fresh produce and irrigation water. All NoV and HPV types found in fresh fruit and vegetable samples were also detected in irrigation water sources, indicating that these viruses are common circulating pathogens in the population and that irrigation water may be the most probable source of viral pathogens in food samples.

9.
Curr Opin Environ Sci Health ; 17: 21-28, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32839746

ABSTRACT

As the novel SARS-CoV-2 was detected in faeces, environmental researchers have been using centrifugal ultrafiltration, polyethylene glycol precipitation and aluminium hydroxide flocculation to describe its presence in wastewater samples. High recoveries (up to 65%) are described with electronegative filtration when using surrogate viruses, but few literature reports recovery efficiencies using accurate quantification of enveloped viruses. Considering that every single virus will have a different behaviour during viral concentration, it is recommended to use an enveloped virus, and if possible, a betacoronaviruses as murine hepatitis virus, as a surrogate. In this review, we show new data from a newly available technology that provides a quick ultrafiltration protocol for SARS-CoV-2. Wastewater surveillance is an efficient system for the evaluation of the relative prevalence of SARS-CoV-2 infections in a community, and there is the need of using reliable concentration methods for an accurate and sensitive quantification of the virus in water.

10.
J Vis Exp ; (147)2019 05 11.
Article in English | MEDLINE | ID: mdl-31132063

ABSTRACT

Viruses excreted by humans and animals may contaminate water sources and pose a risk to human health when this water is used for drinking, food irrigation, washing, etc. The classical fecal bacteria indicator does not always check for the presence of viral pathogens so the detection of viral pathogens and viral indicators is relevant in order to adopt measures of risk mitigation, especially in humanitarian scenarios and in areas where water-borne viral outbreaks are frequent. At present, several commercial tests allowing the quantification of fecal indicator bacteria (FIB) are available for testing at the point of use. However, such commercial tests are not available for the detection of viruses. The detection of viruses in environmental water samples requires concentrating several liters into smaller volumes. Moreover, once concentrated, the detection of viruses relies on methods such as nucleic acid extraction and molecular detection (e.g., polymerase chain reaction [PCR]-based assays) of the viral genomes. The method described here allows the concentration of viruses from 10 L water samples, as well as the extraction of viral nucleic acids at the point of use, with simple and portable equipment. This allows the testing of water samples at the point of use for several viruses and is useful in humanitarian scenarios, as well as at any context where an equipped laboratory is not available. Alternatively, the method allows concentrating viruses present in water samples and the shipping of the concentrate to a laboratory at room temperature for further analysis.


Subject(s)
Point-of-Care Systems , Viruses/isolation & purification , Water Microbiology , Water Pollution/analysis , Animals , Humans , Polymerase Chain Reaction/methods , Viruses/genetics
11.
Int J Biol Macromol ; 118(Pt B): 2021-2031, 2018 Oct 15.
Article in English | MEDLINE | ID: mdl-30021135

ABSTRACT

Amphiphilic ionic complexes of hyaluronic acid and alkyltrimethylphosphonium soaps with alkyl chains containing even numbers of carbons from 12 to 22 have been produced. The complexes have a nearly stoichiometric composition, are non-water soluble, and are stable to heat up to temperatures above 200 °C. These complexes are amphiphilic and able to adopt a biphasic structure with the paraffinic and polysaccharide phases ordered arranged with a periodicity ranging between 3 and 5 nm depending on n. The paraffinic phase in complexes with n ≥ 18 was crystallized and showed melting at temperatures between 58 and 70 °C depending on the n value. The complexes decomposed upon incubation in water under physiological conditions, and undergone extensive biodegradation by the action of hyaluronidases. Biocide assays carried out in both solid and liquid media demonstrated a high antimicrobial activity of the complexes against Gram-positive S. aureus but moderate against Gram-negative E. coli and C. albicans fungi.


Subject(s)
Anti-Infective Agents/pharmacology , Hyaluronic Acid/chemistry , Organophosphorus Compounds/pharmacology , Surface-Active Agents/chemistry , Calorimetry, Differential Scanning , Candida albicans/drug effects , Escherichia coli/drug effects , Hyaluronic Acid/chemical synthesis , Ions , Microbial Sensitivity Tests , Organophosphorus Compounds/chemical synthesis , Organophosphorus Compounds/chemistry , Proton Magnetic Resonance Spectroscopy , Spectroscopy, Fourier Transform Infrared , Staphylococcus aureus/drug effects , Temperature , Thermogravimetry , Water/chemistry , X-Ray Diffraction