Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Klin Monbl Augenheilkd ; 212(5): 326-9, 1998 May.
Article in French | MEDLINE | ID: mdl-9677570

ABSTRACT

BACKGROUND: Previous studies have demonstrated, in the cat, a vasodilatation of retinal vessels in response to neuronal activity induced by diffuse luminance flicker. The aim of this study was to determine whether a similar diameter variation is detectable in humans. MATERIALS AND METHODS: Nine normal subjects were exposed to 1 min of sinusoidally varying diffuse luminance flicker (10 Hz, 30 degrees around optic nerve head). Monochromatic fundus pictures before and after the stimulation were taken. The diameter of retinal arteries and veins was measured on the digitised photographs with the NIH-Image software and an own algorythm. RESULTS: The diameter immediately after flicker was significantly larger than the pre-stimulus diameter by 4.2 +/- 2.2% (p < 0.014) (mean +/- SD) for the retinal arteries and 2.7 +/- 1.7% (p < 0.001) for the retinal veins. Six seconds after cessation of the flicker, arterial diameter was not significantly different from that of pre-flicker value. CONCLUSIONS: Diffuse luminance flicker induces an increase in retinal vessel diameter. This suggest that retinal blood flow is coupled with neuronal activity as previously evidenced by the blue field simulation technique in the macula.


Subject(s)
Flicker Fusion/physiology , Retinal Vessels/physiology , Vasodilation/physiology , Adolescent , Adult , Animals , Cats , Female , Humans , Image Processing, Computer-Assisted , Male , Photic Stimulation
2.
Curr Eye Res ; 16(12): 1252-7, 1997 Dec.
Article in English | MEDLINE | ID: mdl-9426960

ABSTRACT

PURPOSE: To determine retinal vessel diameter variations in response to neuronal activity induced by diffuse luminance flicker. METHODS: The diameter of retinal arteries and veins was measured in 9 normal subjects by computer analysis of fundus pictures taken in monochromatic light under normal conditions of illumination and after 1 min of sinusoidally varying diffuse luminance flicker at 10 Hz. RESULTS: The diameter immediately after flicker was significantly larger than the pre-stimulus diameter by 4.2 +/- 2.2% for the retinal arteries and 2.7 +/- 1.7% for the retinal veins (mean +/- SD). Six is after cessation of the flicker, arterial diameter was not significantly different from that of pre-flicker value. CONCLUSIONS: Diffuse luminance flicker induces an increase in retinal vessel diameter. This increase most probably reflects an increase in retinal blood flow previously evidenced in humans by the blue field simulation technique. The technique needs to be optimized in terms of flicker parameters, to determine whether flicker-evoked retinal diameter changes could represent a useful clinical measure of the capability of the retinal vascular system to vasodilate.


Subject(s)
Lighting , Retinal Vessels/physiology , Retinal Vessels/radiation effects , Vasodilation/physiology , Adolescent , Adult , Arteries/physiology , Female , Humans , Male , Photic Stimulation/methods , Reproducibility of Results , Veins/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...