Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
2.
J Radiol Prot ; 42(2)2022 04 13.
Article in English | MEDLINE | ID: mdl-35354135

ABSTRACT

We aimed to evaluate the impact of a low-dose whole-body computed tomography (WBCT) protocol on radiation doses in paediatric major trauma patients. Retrospective cohort study of paediatric trauma patients (<16 years) at a national level 1 paediatric trauma centre (PTC) over a 6 year period prior and post introduction of a low-dose WBCT protocol (2014-2019). Demographic data, patient characteristics, CT device, and exposure information including scan range, dose-length product, and volume CT dose index were collected. Effective dose (ED) and exposure parameters were compared before and after protocol introduction. Forty-eight patients underwent WBCT during the study period. Prior to introduction of the low-dose protocol (n= 18), the ED was 20.6 mSv (median 20.1 ± 5.3 mSv [range 12.5-30.7]). After introduction of the low-dose WBCT protocol (n= 30), mean ED was 4.8 mSv (median 2.6 ± 5.0 [range: 0.8-19.1]). This resulted in a reduction of 77% in mean ED (pvalue <0.001). Significant radiation dose reduction of 77% can be achieved with low-dose WBCT protocols in PTCs.


Subject(s)
Multiple Trauma , Whole Body Imaging , Child , Humans , Radiation Dosage , Retrospective Studies , Switzerland , Tomography, X-Ray Computed/methods , Whole Body Imaging/methods
3.
Leg Med (Tokyo) ; 20: 68-74, 2016 May.
Article in English | MEDLINE | ID: mdl-27161927

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the feasibility of diagnosing fatal pulmonary thromboembolism (PTE) with unenhanced postmortem computed tomography (PMCT). MATERIALS AND METHODS: Twelve cases with autopsy confirmed PTE and matched controls (n=19) were retrospectively examined for PTE signs on PMCT. The following variables were evaluated: edema of the lower extremities (areal and Hounsfield Unit measurements) and observer dependent patterns of the morphology of the sedimentation in the pulmonary arteries and trunk. RESULTS: The median absolute difference between the areal measurements of the right and left lower leg and thigh and the attenuation of the popliteal adipose tissue did not differ significantly between the groups. In contrast, the categorical assessment of soft tissue edema in the lower extremities was significantly different. A statistically significant difference could also be found in the shape of the vascular content within the pulmonary trunk and arteries. CONCLUSION: PTE may be assessed on unenhanced PMCT using diagnostic clues such as a distinct pattern of the pulmonary artery content and the presence of perivascular edema in the lower extremities.


Subject(s)
Pulmonary Embolism/diagnosis , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Diagnosis , Feasibility Studies , Female , Humans , Male , Middle Aged , Retrospective Studies
4.
Anal Bioanal Chem ; 408(4): 1249-58, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26677021

ABSTRACT

The postmortem redistribution (PMR) phenomenon complicates interpretation in forensic toxicology. Human data on time-dependent PMR are rare and only exist for blood so far. A new method for investigation of time-dependent PMR in blood as well as in alternative body fluids and tissues was developed and evaluated using automated biopsy sampling. At admission of the bodies, introducer needles were placed in liver, lung, kidney, muscle, spleen, adipose tissue, heart, femoral vein, and lumbar spine using a robotic arm guided by a computed tomography scanner (CT). Needle placement accuracy was analyzed and found to be acceptable for the study purpose. Tissue biopsies and small volume body fluid samples were collected in triplicate through the introducer needles. At autopsy (around 24 h after admission), samples from the same body regions were collected. After mastering of the technical challenges, two authentic cases were analyzed as a proof of concept. Drug concentrations of venlafaxine, O-desmethylvenlafaxine, bromazepam, flupentixol, paroxetine, and lorazepam were determined by LC-MS/MS, and the percentage concentration changes between the two time points were calculated. Concentration changes were observed with both increases and decreases depending on analyte and matrix. While venlafaxine, flupentixol, paroxetine, and lorazepam generally showed changes above 30% and more, O-desmethylvenlafaxine and bromazepam did not undergo extensive PMR. The presented study shows that CT-controlled biopsy collection provides a valuable tool for systematic time-dependent PMR investigation, demanding only minimal sample amount and causing minimal damage to the body.


Subject(s)
Image-Guided Biopsy/methods , Postmortem Changes , Autopsy , Chromatography, Liquid , Desvenlafaxine Succinate/analysis , Equipment Design , Female , Flupenthixol/analysis , Forensic Toxicology/methods , Humans , Image-Guided Biopsy/instrumentation , Lorazepam/analysis , Middle Aged , Paroxetine/analysis , Robotics/instrumentation , Tandem Mass Spectrometry , Time Factors , Tissue Distribution , Tomography, X-Ray Computed , Venlafaxine Hydrochloride/analysis
5.
Forensic Sci Med Pathol ; 11(2): 162-7, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25724838

ABSTRACT

The aim of this study was to evaluate the diagnostic criteria and to identify the radiological signs (derived from known radiological signs) for the detection of aortic dissections using postmortem computed tomography (PMCT). Thirty-three aortic dissection cases were retrospectively evaluated; all underwent PMCT and autopsy. The images were initially evaluated independently by two readers and were subsequently evaluated in consensus. Known radiological signs, such as dislocated calcification and an intimomedial flap, were identified. The prevalence of the double sedimentation level in the true and false lumen of the dissected aorta was assessed and defined as a postmortem characteristic sign of aortic dissection. Dislocated calcification was detected in 85% of the cases with aortic calcification; whereas in 54% of the non-calcified aortas, the intimomedial flap could also be recognized. Double sedimentation was identified in 16/33 of the cases. Overall, in 76% (25/33) of the study cases, the described signs, which are indicative for aortic dissection, could be identified. In this study, three diagnostic criteria of aortic dissection were identified using non-enhanced PMCT images of autopsy-confirmed dissection cases.


Subject(s)
Aorta/injuries , Aortography , Autopsy/methods , Tomography, X-Ray Computed , Blood Sedimentation , Forensic Pathology , Humans , Retrospective Studies , Tunica Intima/diagnostic imaging , Tunica Intima/injuries , Tunica Media/diagnostic imaging , Tunica Media/injuries , Vascular Calcification/diagnostic imaging
6.
Forensic Sci Med Pathol ; 11(1): 20-8, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25566768

ABSTRACT

PURPOSE: To investigate the dual-energy CT behavior of cocaine and heroin and of typical adulterants, and to evaluate the elemental composition of pure cocaine and heroin compared with cocaine and heroin in bodypacks. METHODS: Pure heroin and pure synthetic cocaine samples, eight different adulterants, and in each case ten different bodypacks containing cocaine or heroin, were imaged at 80, 100, 120, and 140 kVp in a dual source CT system at two different degrees of compression. Two radiologists, blinded to the samples, measured the attenuation. The dual-energy index (DEI) was calculated. We performed atomic mass spectrometry for the elemental analysis of pure cocaine, pure heroin, and heroin and cocaine in bodypacks, and 140 kVp in a dual-source CT system. RESULTS: Inter- and intra-observer agreement for attenuation measurements was good (r = 0.61-0.72; p < 0.01). The cocaine bodypacks had a positive DEI of 0.029, while the pure drugs and the heroin bodypacks had a negative DEI (-0.051 to -0.027). Levamisole was the only substance which expressed a positive DEI of 0.011, while the remaining adulterants had negative DEIs ranging between -0.015 and -0.215. Atomic mass spectrometry revealed a concentration of tin in the cocaine bodypack that was 67 times higher than in the pure synthetic cocaine sample. CONCLUSIONS: The different DEIs of bodypacks containing cocaine and heroin allow them to be distinguished with dual-energy CT. Although the material properties of pure cocaine, pure heroin, or common drug extenders do not explain the differences in DEI, tin contamination during illicit natural cocaine production may be a possible explanation.


Subject(s)
Cocaine/analysis , Drug Contamination , Drug Trafficking , Foreign Bodies/diagnostic imaging , Heroin/analysis , Multidetector Computed Tomography , Humans , Mass Spectrometry , Observer Variation , Reproducibility of Results
7.
Eur J Radiol ; 82(2): 264-9, 2013 Feb.
Article in English | MEDLINE | ID: mdl-23116807

ABSTRACT

PURPOSE: To investigate the ex vivo performance of high-resolution computed tomography (CT) for quantitative assessment of percentage diameter stenosis in coronary arteries compared to histopathology. MATERIALS AND METHODS: High-resolution CT was performed in 26 human heart specimens after the injection of iodinated contrast media into the coronary arteries. Coronary artery plaques were visually identified on CT images and the grade of stenosis for each plaque was measured with electronic calipers. All coronary plaques were characterized by histopathology according to the Stary classification, and the percentage of stenosis was measured. RESULTS: CT depicted 84% (274/326) of all coronary plaques identified by histology. Missed plaques by CT were of Stary type I (n=31), type II (n=16), and type III (n=5). The stenosis degree significantly correlated between CT and histology (r=0.81, p<0.001). CT systematically overestimated the stenosis of calcified plaques (mean difference - 11.0 ± 9.5%, p<0.01) and systematically underestimated the stenosis of non-calcified plaques (mean difference -6.8 ± 10.4%, p<0.05), while there was no significant difference for mixed-type plaques (mean difference -0.4 ± 11.7%, p=0.85). There was a significant underestimation of stenosis degree as measured by CT for Stary II plaques (mean difference -14 ± 9%, p<0.01) and a significant overestimation for Stary VII plaques (mean difference 9 ± 10%, p<0.05), but there was no significant difference in stenosis degree between both modalities for other plaque types. CONCLUSIONS: High-resolution CT reliably depicts advanced stage coronary plaques with an overall good correlation of stenosis degree compared to histology, however, the degree of stenosis is systematically overestimated in calcified and underestimated in non-calcified plaques.


Subject(s)
Coronary Angiography/methods , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/pathology , Radiographic Image Enhancement/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
8.
Insights Imaging ; 2(2): 149-159, 2011 Apr.
Article in English | MEDLINE | ID: mdl-22347944

ABSTRACT

The energy spectrum of X-ray photons after passage through an absorber contains information about its elemental composition. Thus, tissue characterisation becomes feasible provided that absorption characteristics can be measured or differentiated. Dual-energy CT uses two X-ray spectra enabling material differentiation by analysing material-dependent photo-electric and Compton effects. Elemental concentrations can thereby be determined using three-material decomposition algorithms. In comparison to dual-energy CT used in clinical practice, recently developed energy-sensitive photon-counting detectors sample the material-specific attenuation curves at multiple energy levels and within narrow energy bands; the latter allows the detection of element-specific, k-edge discontinuities of the photo-electric cross section. Multi-energy CT imaging therefore is able to concurrently identify multiple materials with increased accuracy. These specific data on material distribution provide information beyond morphological CT, and approach functional imaging. This article reviews the principles of dual- and multi-energy CT imaging, hardware approaches and clinical applications.

9.
Insights Imaging ; 2(3): 349-356, 2011 Jun.
Article in English | MEDLINE | ID: mdl-22347958

ABSTRACT

Cardiac magnetic resonance imaging and echocardiography are often the primary imaging techniques for many patients with congenital heart disease (CHD). However, with modern generations of CT systems and recent advances in temporal and spatial resolution, cardiac CT has been gaining an increasing reputation in the field of cardiac imaging and in the evaluation of patients with congenital heart disease. The CT imaging protocol depends on the suspected cardiac defect, the type of previous surgical repair, and the patient's age and level of cooperation. Various strategies are available for reducing radiation exposure, which is of utmost importance particularly in paediatric patients. A sequential segmental analysis is a commonly used approach to analysing congenital heart defects. Familiarity of the performing radiologist with dedicated CT protocols, the complex anatomy, morphology and terminology of CHD, as well as with the surgical procedures used to correct congenital abnormalities is a prerequisite for correct diagnosis.

SELECTION OF CITATIONS
SEARCH DETAIL
...