Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Crit Care ; 28(1): 40, 2024 02 05.
Article in English | MEDLINE | ID: mdl-38317262

ABSTRACT

BACKGROUND: Ventilator associated pneumonia (VAP) due to wild-type AmpC-producing Enterobacterales (wtAE) is frequent in intensive care unit (ICU) patients. Despite a low level of evidence, definitive antimicrobial therapy (AMT) with third generation cephalosporins (3GCs) or piperacillin is discouraged. METHODS: Observational prospective study including consecutive wtAE VAP patients in 20 French ICUs. The primary objective was to assess the association of the choice of definitive AMT, i.e. piperacillin ± tazobactam (PTZ), 3GCs or other molecule (4GCs, carbapenems, quinolones, cotrimoxazole; control group), with treatment success at day-7. Recurrence of infection was collected as a secondary outcome, and analyzed accounting for the competing risk of death. RESULTS: From February 2021 to June 2022, 274 patients were included. Enterobacter cloacae was the most prevalent specie (31%). Seventy-eight patients (28%) had PTZ as definitive AMT while 44 (16%) had 3GCs and 152 (56%) were classified in the control group. Day-7 success rate was similar between the 3 groups (74% vs. 73% vs. 68% respectively, p = 0.814). Recurrence probability at day-28 was 31% (95% CI 21-42), 40% (95% CI 26-55) and 21% (95% CI 15-28) for PTZ, 3GCs and control groups (p = 0.020). In multivariable analysis, choice of definitive AMT was not associated with clinical success, but definitive AMT with 3GCs was associated with recurrence at day-28 [csHR(95%CI) 10.9 (1.92-61.91)]. CONCLUSION: Choice of definitive antimicrobial therapy was not associated with treatment success at day 7. However, recurrence of pneumonia at day-28 was higher in patients treated with third generation cephalosporins with no differences in mortality or mechanical ventilation duration.


Subject(s)
Anti-Bacterial Agents , Pneumonia, Ventilator-Associated , Humans , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/therapeutic use , Prospective Studies , Pneumonia, Ventilator-Associated/drug therapy , Critical Illness/therapy , Piperacillin/therapeutic use , Piperacillin, Tazobactam Drug Combination/therapeutic use , Intensive Care Units
2.
J Clin Med ; 12(5)2023 Mar 03.
Article in English | MEDLINE | ID: mdl-36902815

ABSTRACT

During acute respiratory distress syndrome (ARDS), the increase in pulmonary vascular permeability and lung water induced by pulmonary inflammation may be related to altered lung compliance. A better understanding of the interactions between respiratory mechanics variables and lung water or capillary permeability would allow a more personalized monitoring and adaptation of therapies for patients with ARDS. Therefore, our main objective was to investigate the relationship between extravascular lung water (EVLW) and/or pulmonary vascular permeability index (PVPI) and respiratory mechanic variables in patients with COVID-19-induced ARDS. This is a retrospective observational study from prospectively collected data in a cohort of 107 critically ill patients with COVID-19-induced ARDS from March 2020 to May 2021. We analyzed relationships between variables using repeated measurements correlations. We found no clinically relevant correlations between EVLW and the respiratory mechanics variables (driving pressure (correlation coefficient [CI 95%]: 0.017 [-0.064; 0.098]), plateau pressure (0.123 [0.043; 0.202]), respiratory system compliance (-0.003 [-0.084; 0.079]) or positive end-expiratory pressure (0.203 [0.126; 0.278])). Similarly, there were no relevant correlations between PVPI and these same respiratory mechanics variables (0.051 [-0.131; 0.035], 0.059 [-0.022; 0.140], 0.072 [-0.090; 0.153] and 0.22 [0.141; 0.293], respectively). In a cohort of patients with COVID-19-induced ARDS, EVLW and PVPI values are independent from respiratory system compliance and driving pressure. Optimal monitoring of these patients should combine both respiratory and TPTD variables.

3.
Anesthesiology ; 136(1): 162-175, 2022 01 01.
Article in English | MEDLINE | ID: mdl-34788380

ABSTRACT

BACKGROUND: The relationship between the diaphragm thickening fraction and the transdiaphragmatic pressure, the reference method to evaluate the diaphragm function, has not been clearly established. This study investigated the global and intraindividual relationship between the thickening fraction of the diaphragm and the transdiaphragmatic pressure. The authors hypothesized that the diaphragm thickening fraction would be positively and significantly correlated to the transdiaphragmatic pressure, in both healthy participants and ventilated patients. METHODS: Fourteen healthy individuals and 25 mechanically ventilated patients (enrolled in two previous physiologic investigations) participated in the current study. The zone of apposition of the right hemidiaphragm was imaged simultaneously to transdiaphragmatic pressure recording within different breathing conditions, i.e., external inspiratory threshold loading in healthy individuals and various pressure support settings in patients. A blinded offline breath-by-breath analysis synchronously computed the changes in transdiaphragmatic pressure, the diaphragm pressure-time product, and diaphragm thickening fraction. Global and intraindividual relationships between variables were assessed. RESULTS: In healthy subjects, both changes in transdiaphragmatic pressure and diaphragm pressure-time product were moderately correlated to diaphragm thickening fraction (repeated measures correlation = 0.40, P < 0.0001; and repeated measures correlation = 0.38, P < 0.0001, respectively). In mechanically ventilated patients, changes in transdiaphragmatic pressure and thickening fraction were weakly correlated (repeated measures correlation = 0.11, P = 0.008), while diaphragm pressure-time product and thickening fraction were not (repeated measures correlation = 0.04, P = 0.396). Individually, changes in transdiaphragmatic pressure and thickening fraction were significantly correlated in 8 of 14 healthy subjects (ρ = 0.30 to 0.85, all P < 0.05) and in 2 of 25 mechanically ventilated patients (ρ = 0.47 to 0.64, all P < 0.05). Diaphragm pressure-time product and thickening fraction correlated in 8 of 14 healthy subjects (ρ = 0.41 to 0.82, all P < 0.02) and in 2 of 25 mechanically ventilated patients (ρ = 0.63 to 0.66, all P < 0.01). CONCLUSIONS: Overall, diaphragm function as assessed with transdiaphragmatic pressure was weakly related to diaphragm thickening fraction. The diaphragm thickening fraction should not be used in healthy subjects or ventilated patients when changes in diaphragm function are evaluated.


Subject(s)
Diaphragm/diagnostic imaging , Diaphragm/physiology , Pressure , Respiration, Artificial/methods , Respiratory Function Tests/methods , Adult , Aged , Healthy Volunteers , Humans , Middle Aged , Organ Size/physiology , Prospective Studies , Respiration, Artificial/trends , Respiratory Function Tests/trends , Young Adult
4.
Crit Care ; 24(1): 669, 2020 11 27.
Article in English | MEDLINE | ID: mdl-33246478

ABSTRACT

BACKGROUND: Diaphragm dysfunction is highly prevalent in mechanically ventilated patients. Recent work showed that changes in diaphragm shear modulus (ΔSMdi) assessed using ultrasound shear wave elastography (SWE) are strongly related to changes in Pdi (ΔPdi) in healthy subjects. The aims of this study were to investigate the relationship between ΔSMdi and ΔPdi in mechanically ventilated patients, and whether ΔSMdi is responsive to change in respiratory load when varying the ventilator settings. METHODS: A prospective, monocentric study was conducted in a 15-bed ICU. Patients were included if they met the readiness-to-wean criteria. Pdi was continuously monitored using a double-balloon feeding catheter orally introduced. The zone of apposition of the right hemidiaphragm was imaged using a linear transducer (SL10-2, Aixplorer, Supersonic Imagine, France). Ultrasound recordings were performed under various pressure support settings and during a spontaneous breathing trial (SBT). A breath-by-breath analysis was performed, allowing the direct comparison between ΔPdi and ΔSMdi. Pearson's correlation coefficients (r) were used to investigate within-individual relationships between variables, and repeated measure correlations (R) were used for determining overall relationships between variables. Linear mixed models were used to compare breathing indices across the conditions of ventilation. RESULTS: Thirty patients were included and 930 respiratory cycles were analyzed. Twenty-five were considered for the analysis. A significant correlation was found between ΔPdi and ΔSMdi (R = 0.45, 95% CIs [0.35 0.54], p < 0.001). Individual correlation displays a significant correlation in 8 patients out of 25 (r = 0.55-0.86, all p < 0.05, versus r = - 0.43-0.52, all p > 0.06). Changing the condition of ventilation similarly affected ΔPdi and ΔSMdi. Patients in which ΔPdi-ΔSMdi correlation was non-significant had a faster respiratory rate as compared to that of patient with a significant ΔPdi-ΔSMdi relationship (median (Q1-Q3), 25 (18-33) vs. 21 (15-26) breaths.min-1, respectively). CONCLUSIONS: We demonstrate that ultrasound SWE may be a promising surrogate to Pdi in mechanically ventilated patients. Respiratory rate appears to negatively impact SMdi measurement. Technological developments are needed to generalize this method in tachypneic patients. TRIAL REGISTRATION: NCT03832231 .


Subject(s)
Diaphragm/diagnostic imaging , Elasticity Imaging Techniques/methods , Ventilator Weaning/standards , Aged , Diaphragm/abnormalities , Elasticity Imaging Techniques/statistics & numerical data , Female , France , Humans , Male , Middle Aged , Prospective Studies , Respiration, Artificial/instrumentation , Respiration, Artificial/methods , Respiration, Artificial/statistics & numerical data , Respiratory Mechanics/physiology , Ultrasonography/methods , Ultrasonography/statistics & numerical data , Ventilator Weaning/instrumentation , Ventilator Weaning/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...