Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Clin Exp Dent ; 11(11): e1006-e1011, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31700574

ABSTRACT

BACKGROUND: The purpose of this in vitro study was to evaluate the impact of the remaining tooth structure on the retention of overdenture cast metal copings. MATERIAL AND METHODS: A freshly extracted intact mandibular human canine (length 25 mm) was selected and endodontically treated. An incisal reduction of 4 mm with no ferrule preparation was performed and a post space of 12 mm was created. By using polyvinyl siloxane duplication material and autopolymerizing polymethylmethacrylate resin, ten resin teeth analogs (control group) were obtained. A second set of ten resin teeth analogs (group 1) was created by preparing on the original natural tooth a 360o ferrule design of 1 mm in height and by using the same procedural technique. The canine was further reduced by an additional 1 mm, resulting in a ferrule of 2 mm in height, measured from the initial incisal reduction, thus a third set of ten resin teeth analogs (group 2) was created. For every tooth analog in all groups a dome-shaped metal coping was cast and luted with a glass ionomer cement. All specimens were subjected to tensile load testing until decementation occurred. RESULTS: The specimens in the control group exhibited a mean failure load of 87.21 ± 18.26 N, while the 1 mm ferrule group recorded a higher mean failure load of 125.43 ± 8.79 N and the 2 mm ferrule group recorded the highest mean failure load of 146.12 ± 23.38 N. One-way ANOVA revealed significant differences (F= 28.04, p<0.001) in the tensile failure loads between all of the groups being tested. CONCLUSIONS: The metal copings with a 2 mm ferrule design exhibited the highest retention values, followed by the 1 mm ferrule and the no ferrule design, with the differences among them being statistically significant. Key words:Ferrule effect, In vitro study, Metal copings, Overdenture, Tensile stress.

2.
J Prosthet Dent ; 112(1): 70-8, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24674809

ABSTRACT

STATEMENT OF PROBLEM: Different inlay casting waxes do not produce copings with satisfactory marginal accuracy when used on different die materials. PURPOSE: The purpose of this study was to evaluate the marginal accuracy of 4 inlay casting waxes on stone dies and titanium and zirconia abutments and to correlate the findings with the degree of wetting between the die specimens and the inlay casting waxes. MATERIAL AND METHODS: The inlay casting waxes tested were Starwax (Dentaurum), Unterziehwachs (Bredent), SU Esthetic wax (Schuler), and Sculpturing wax (Renfert). The marginal opening of the waxes was measured with a stereomicroscope on high-strength stone dies and on titanium and zirconia abutments. Photographic images were obtained, and the mean marginal opening for each specimen was calculated. A total of 1440 measurements were made. Wetting between die materials and waxes was determined after fabricating stone, titanium, and zirconia rectangular specimens. A calibrated pipette was used to place a drop of molten wax onto each specimen. The contact angle was calculated with software after an image of each specimen had been made with a digital camera. Collected data were subjected to a 2-way analysis of variance (α=.05). Any association between marginal accuracy and wetting of different materials was found by using the Pearson correlation. RESULTS: The wax factor had a statistically significant effect both on the marginal discrepancy (F=158.31, P<.001) and contact angle values (F=68.09, P<.001). A statistically significant effect of the die material factor both on the marginal adaptation (F=503.47, P<.001) and contact angle values (F=585.02, P<.001) was detected. A significant correlation between the marginal accuracy and the contact angle values (Pearson=0.881, P=.01) was also found. CONCLUSIONS: Stone dies provided wax copings with the best marginal integrity, followed by titanium and zirconia abutments. Unterziehwachs (Bredent), wax produced the best marginal adaptation on different die materials. A significant correlation was found between the marginal accuracy and the contact angle values. As the contact angle value became smaller, the marginal accuracy improved. All combinations of waxes and stone and titanium dies presented a high wettability.


Subject(s)
Calcium Sulfate/chemistry , Dental Abutments , Dental Materials/chemistry , Inlay Casting Wax/chemistry , Titanium/chemistry , Zirconium/chemistry , Dental Marginal Adaptation , Humans , Image Processing, Computer-Assisted/methods , Materials Testing , Photography/methods , Polymethyl Methacrylate/chemistry , Surface Properties , Wettability
SELECTION OF CITATIONS
SEARCH DETAIL
...