Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Publication year range
1.
J Ultrasound ; 27(1): 97-104, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37668901

ABSTRACT

PURPOSE: The passive leg raising test (PLR) is a noninvasive method widely adopted to assess fluid responsiveness. We propose to explore if changes in the carotid flow assessed by echo-Doppler can predict fluid responsiveness after a PLR. METHODS: We conducted a performance diagnostic study in two intensive care units from Argentina between February and April 2022. We included patients with signs of tissular hypoperfusion that required fluid resuscitation. We labeled the patients as fluid responders when we measured, after a fluid bolus, an increase greater than 15% in the left ventricle outflow tract (LVOT) VTI in an apical 5-chamber view and we compared those results with the carotid flow (CF) velocity-time integral (VTI) from the left supraclavicular region in a semi-recumbent position and during the PLR. RESULTS: Of the 62 eligible patients, 50 patients (80.6%) were included. The area under the ROC curve for a change in CF VTI during the PLR test was 0.869 (95% CI 0.743-0.947). An increase of at least of 11% in the CF VTI with the PLR predicted fluid-responsiveness with a sensitivity of 77.3% (95% CI 54.6-92.2%) and specificity of 78.6% (95% CI 59-91.7%). The positive predictive value was 73.9% (95% CI 57.4-85.6%) and the negative predictive value was 81.5% (95% CI 66.5-90.7%). The positive likelihood ratio was 3.61 and the negative likelihood ratio was 0.29. CONCLUSION: An increase greater than 11% in CF VTI after a PLR may be useful to predict fluid responsiveness among critically ill patients.


Subject(s)
Intensive Care Units , Leg , Humans , Leg/diagnostic imaging , ROC Curve
2.
J Ultrasound ; 2022 Sep 21.
Article in English | MEDLINE | ID: mdl-36127570

ABSTRACT

PURPOSE: The passive leg raising test (PLR) produces a reversible increase in venous return and, if the patient's ventricles are preload dependent, in the cardiac output. As this effect occurs in seconds, the transthoracic echocardiography is optimal for its real time assessment. The utility of the PLR for monitoring fluid responsiveness through the measurement of the left ventricle outflow tract velocity-time integral (LVOT VTI) in an apical 5-chamber view is well stablished. To achieve this view in critically ill patients is often challenging. The aim of this study is to explore the accuracy for predicting fluid responsiveness of the change in the right ventricle outflow tract velocity-time integral (RVOT VTI) from a subcostal view during a PLR. METHODS: This is a diagnostic accuracy study carried out in two centers in Argentina. We included patients admitted to the intensive care unit from January 2022 to April 2022, that required fluid expansion due to signs of tissular hypoperfusion. We measured the RVOT VTI from a subcostal view in a semi-recumbent position and during the PLR, and the LVOT VTI in an apical 5-chamber view before and after a fluid bolus. If the LVOT VTI increased by 15% after the fluid bolus, the patients were considered fluid responders. RESULTS: We included 43 patients. The area under the ROC curve for a change in the RVOT VTI during the PLR was 0.879 (95% CI 0.744-0.959). A change of 15.36% in the RVOT VTI with the PLR predicted fluid responsiveness with a sensitivity of 85.7% (95% CI 57.2%-98.2%) and specificity of 93.1% (95% CI 77.2-99.2). The positive predictive value was 85.7% (95% CI 60.8%-95.9%) and the negative predictive value was 93.1% (95% CI 78.8%-98%). The positive likelihood ratio was 12.43 and the negative predictive value was 0.15. CONCLUSION: The RVOT VTI change during a PLR is suitable for the prediction of fluid responsiveness in critically ill patients.

3.
Noticias CEAMSE ; 8(14): 29-32, ene./feb. 1999.
Article in Spanish | BINACIS | ID: bin-139543

ABSTRACT

Trabajo ganador de un concurso de monografías del proyecto "Jóvenes en acción: tecnología y medio ambiente en la ciudad de Buenos Aires". El trabajo se refiere a la falta de espacios verdes


Subject(s)
Argentina , Recreational Zones
4.
Buenos Aires; ene./feb. 1999. (Noticias CEAMSE, 8, 14).
Monography in Spanish | BINACIS | ID: biblio-1221295

ABSTRACT

Trabajo ganador de un concurso de monografías del proyecto "Jóvenes en acción: tecnología y medio ambiente en la ciudad de Buenos Aires". El trabajo se refiere a la falta de espacios verdes


Subject(s)
Argentina , Recreational Zones
SELECTION OF CITATIONS
SEARCH DETAIL
...