1.
AJNR Am J Neuroradiol ; 40(10): 1759-1765, 2019 10.
Article in English | MEDLINE | ID: mdl-31558504

ABSTRACT

BACKGROUND AND PURPOSE: Selection of the correct flow-diverter size is critical for cerebral aneurysm treatment success, but it remains challenging due to the interplay of device size, anatomy, and deployment. Current convention does not address these challenges well. The goals of this pilot study were to determine whether computational modeling improves flow-diverter sizing over current convention and to validate simulated deployments. MATERIALS AND METHODS: Seven experienced neurosurgeons and interventional neuroradiologists used computational modeling to prospectively plan 19 clinical interventions. In each patient case, physicians simulated 2-4 flow-diverter sizes that were under consideration based on preprocedural imaging. In addition, physicians identified a preferred device size using the current convention. A questionnaire on the impact of computational modeling on the procedure was completed immediately after treatment. Rotational angiography image data were acquired after treatment and compared with flow-diverter simulations to validate the output of the software platform. RESULTS: According to questionnaire responses, physicians found the simulations useful for treatment planning, and they increased their confidence in device selection in 94.7% of cases. After viewing the simulations results, physicians selected a device size that was different from the original conventionally planned device size in 63.2% of cases. The average absolute difference between clinical and simulated flow-diverter lengths was 2.1 mm. In 57% of cases, average simulated flow-diverter diameters were within the measurement uncertainty of clinical flow-diverter diameters. CONCLUSIONS: Physicians found computational modeling to be an impactful and useful tool for flow-diverter treatment planning. Validation results showed good agreement between simulated and clinical flow-diverter diameters and lengths.


Subject(s)
Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis , Computer Simulation , Intracranial Aneurysm/surgery , Female , Humans , Male , Pilot Projects , Software
2.
Perfusion ; 29(1): 82-8, 2014 Jan.
Article in English | MEDLINE | ID: mdl-23868320

ABSTRACT

Mechanical circulatory support emerged for the pediatric population in the late 1980s as a bridge to cardiac transplantation. The Total Artificial Heart (TAH-t) (SynCardia Systems Inc., Tuscon, AZ) has been approved for compassionate use by the Food and Drug Administration for patients with end-stage biventricular heart failure as a bridge to heart transplantation since 1985 and has had FDA approval since 2004. However, of the 1,061 patients placed on the TAH-t, only 21 (2%) were under the age 18. SynCardia Systems, Inc. recommends a minimum patient body surface area (BSA) of 1.7 m(2), thus, limiting pediatric application of this device. This unique case report shares this pediatric institution's first experience with the TAH-t. A 14-year-old male was admitted with dilated cardiomyopathy and severe biventricular heart failure. The patient rapidly decompensated, requiring extracorporeal life support. An echocardiogram revealed severe biventricular dysfunction and diffuse clot formation in the left ventricle and outflow tract. The decision was made to transition to biventricular assist device. The biventricular failure and clot formation helped guide the team to the TAH-t, in spite of a BSA (1.5 m(2)) below the recommendation of 1.7 m(2). A computed tomography (CT) scan of the thorax, in conjunction with a novel three-dimensional (3D) modeling system and team, assisted in determining appropriate fit. Chest CT and 3D modeling following implantation were utilized to determine all major vascular structures were unobstructed and the bronchi were open. The virtual 3D model confirmed appropriate device fit with no evidence of compression to the left pulmonary veins. The postoperative course was complicated by a left lung opacification. The left lung anomalies proved to be atelectasis and improved with aggressive recruitment maneuvers. The patient was supported for 11 days prior to transplantation. Chest CT and 3D modeling were crucial in assessing whether the device would fit, as well as postoperative complications in this smaller pediatric patient.


Subject(s)
Cardiomyopathy, Dilated/surgery , Heart Failure/surgery , Heart Transplantation/methods , Heart, Artificial , Adolescent , Cardiomyopathy, Dilated/therapy , Heart Failure/therapy , Humans , Male