Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
EuroIntervention ; 19(9): 766-771, 2023 Nov 17.
Article in English | MEDLINE | ID: mdl-37605804

ABSTRACT

About one-third of patients undergoing transcatheter aortic valve implantation (TAVI) use oral anticoagulants (OAC), mainly due to atrial fibrillation. General guidelines advise interrupting OAC in patients with a high risk of bleeding undergoing interventions. However, preliminary observational data suggest that the continuation of OAC during TAVI is safe and may reduce the risk of periprocedural thromboembolic events. The Periprocedural Continuation Versus Interruption of Oral Anticoagulant Drugs During Transcatheter Aortic Valve Implantation (POPular PAUSE TAVI) is a multicentre, randomised clinical trial with open-label treatment and blinded endpoint assessment. Patients are randomised 1:1 to periprocedural continuation versus interruption of OAC and are stratified for vitamin K antagonist or direct oral anticoagulant use. The primary endpoint is a composite of cardiovascular mortality, all stroke, myocardial infarction, major vascular complications and type 2-4 bleeding within 30 days after TAVI, according to the Valve Academic Research Consortium-3 criteria. Secondary endpoints include separate individual and composite outcomes, quality of life and cost-effectiveness. Since continuation of OAC is associated with the ancillary benefit that it simplifies periprocedural management, the primary outcome is first analysed for non-inferiority; if non-inferiority is proven, superiority will be tested. Recruitment started in November 2020, and the trial will continue until a total of 858 patients have been included and followed for 90 days. In summary, POPular PAUSE TAVI is the first randomised clinical trial to assess the safety and efficacy of periprocedural continuation versus interruption of OAC in patients undergoing TAVI.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Quality of Life , Anticoagulants/therapeutic use , Hemorrhage , Treatment Outcome , Aortic Valve/surgery , Risk Factors
2.
JAMA Cardiol ; 8(7): 703-708, 2023 07 01.
Article in English | MEDLINE | ID: mdl-37203243

ABSTRACT

Importance: Titanium-nitride-oxide (TiNO)-coated stents show faster strut coverage compared with drug-eluting stents without excessive intimal-hyperplasia observed in bare metal stents. It is important to study long-term clinical outcomes after treatment of patients with an acute coronary syndrome (ACS) by TiNO-coated stents, which are neither drug-eluting stents nor bare metal stents. Objective: To compare the rate of main composite outcome of cardiac death, myocardial infarction (MI), or ischemia-driven target lesion revascularization at 5 years in patients with ACS randomized to receive either a TiNO-coated stent or a third-generation everolimus-eluting stent (EES). Design, Setting, and Participants: This multicenter, randomized, controlled, open-label trial was conducted in 12 clinical sites in 5 European countries and enrolled patients from January 2014 to August 2016. Patients presenting with ACS (ST-segment elevation MI, non-ST-segment elevation MI, and unstable angina) with at least 1 de novo lesion were randomized to receive either a TiNO-coated stent or an EES. The present report analyzes the long-term follow-up for the main composite outcome and its individual components. Analysis took place between November 2022 to March 2023. Main outcome: The primary end point was a composite of cardiac death, MI, or target lesion revascularization at 12-month follow-up. Results: A total of 1491 patients with ACS were randomly assigned to receive either TiNO-coated stents (989 [66.3%]) or EES (502 [33.7%]). The mean (SD) age was 62.7 (10.8) years, and 363 (24.3%) were female. At 5 years, the main composite outcome events occurred in 111 patients (11.2%) in the TiNO group vs 60 patients (12%) in the EES group (hazard ratio [HR], 0.94; 95% CI, 0.69-1.28; P = .69). The rate of cardiac death was 0.9% (9 of 989) vs 3.0% (15 of 502) (HR, 0.30; 95% CI, 0.13-0.69; P = .005), the rate of MI was 4.6% (45 of 989) vs 7.0% (35 of 502) (HR, 0.64; 95% CI, 0.41-0.99; P = .049), the rate of stent thrombosis was 1.2% (12 of 989) vs 2.8% (14 of 502) (HR, 0.43; 95% CI, 0.20-0.93; P = .034), and the rate of target lesion revascularization was 7.4% (73 of 989) vs 6.4% (32 of 502) (HR, 1.16; 95% CI, 0.77-1.76; P = .47) in the TiNO-coated stent arm and in the EES arm, respectively. Conclusion and relevance: In this study, patients with ACS had a main composite outcome that was not different 5 years after TiNO-coated stent or EES. Trial Registration: ClinicalTrials.gov Identifier: NCT02049229.


Subject(s)
Acute Coronary Syndrome , Drug-Eluting Stents , Myocardial Infarction , Percutaneous Coronary Intervention , Humans , Female , Middle Aged , Male , Everolimus/pharmacology , Everolimus/therapeutic use , Acute Coronary Syndrome/surgery , Acute Coronary Syndrome/drug therapy , Treatment Outcome , Percutaneous Coronary Intervention/adverse effects , Stents , Myocardial Infarction/epidemiology , Myocardial Infarction/etiology , Death
3.
Catheter Cardiovasc Interv ; 101(3): 505-510, 2023 02.
Article in English | MEDLINE | ID: mdl-36651339

ABSTRACT

OBJECTIVE: The elevated risk of adverse events following percutaneous coronary intervention in diabetic patients persists with newer-generation DES. The polymer-free amphilimus-eluting stent (PF-AES) possesses characteristics with a potentially enhanced performance in patients with diabetes. Data from the 1-year follow-up period has been previously published. The aim of this subanalysis was to assess long-term performance of two contemporary drug-eluting stents (DES) in a diabetic population. METHODS: In the ReCre8 trial, patients were stratified for diabetes and troponin status, and randomized to implantation of a permanent polymer zotarolimus-eluting stent (PP-ZES) or PF-AES. The primary endpoint was target-lesion failure (TLF), a composite of cardiac death, target-vessel myocardial infarction and target-lesion revascularization. Clinical outcomes between discharge and 3 years follow-up were assessed. RESULTS: A total of 302 patients with diabetes were included in this analysis. After 3 years, TLF occurred in 12.5% of PP-ZES patients versus 10.0% in PF-AES patients (p = 0.46). Similarly, the separate components of TLF were comparable between the two study arms. The secondary composite endpoint of NACE was higher in the PP-ZES arm with 45 cases (29.6%) versus 30 cases (20.0%) in the PF-AES arm (p = 0.036). In the insulin-dependent diabetic population, TLF occurred in 19.1% of PP-ZES patients versus 10.4% of PF-AES patients (p = 0.21). NACE occurred in 40.4% of PP-ZES patients versus 27.1% of PF-AES patients (p = 0.10). CONCLUSIONS: This subanalysis shows that the use of PF-AES results in similar clinical outcomes as compared to PP-ZES, yet some benefits of use of PF-AES in diabetic patients may prevail. Future dedicated trials should confirm these findings.


Subject(s)
Cardiovascular Agents , Coronary Artery Disease , Diabetes Mellitus , Drug-Eluting Stents , Percutaneous Coronary Intervention , Humans , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Artery Disease/chemically induced , Follow-Up Studies , Risk Factors , Treatment Outcome , Diabetes Mellitus/diagnosis , Percutaneous Coronary Intervention/adverse effects , Prosthesis Design , Cardiovascular Agents/adverse effects
4.
Catheter Cardiovasc Interv ; 99(2): 366-372, 2022 02.
Article in English | MEDLINE | ID: mdl-33811730

ABSTRACT

OBJECTIVES: The purpose of this analysis was to compare target-lesion failure (TLF) of a permanent polymer zotarolimus-eluting stent (PP-ZES) versus a polymer-free amphilimus-eluting stent (PF-AES) in diabetics. BACKGROUND: The improvement of outcomes with new-generation drug-eluting stent as seen in the general population is less pronounced among diabetics. The PF-AES introduces an elution-technology with potential enhanced performance in diabetics. METHODS: In this subanalysis of the ReCre8 trial, patients were randomized to either a PP-ZES or PF-AES after stratification for diabetes and troponin status. The primary device-oriented endpoint was TLF, a composite of cardiac death, target-vessel myocardial infarction and target-lesion revascularization. RESULTS: In the ReCre8 trial, 304 (20%) patients were diabetic and 96 (6%) had insulin-dependent diabetes mellitus. There was no statistically significant difference between the two study arms regarding the primary endpoint (PP-ZES 7.2% vs. PF-AES 4.0%; p = .21), although the composite of net adverse clinical events was higher in the PP-ZES arm (15.7 vs. 8.0%; p = .035). Stent thrombosis was low in both groups with no cases in the PP-ZES arm and 1 case in the PF-AES arm (p = .32). Regarding insulin-treated diabetics, TLF was higher in the PP-ZES arm (14.9 vs. 2.1%; p = .022). CONCLUSIONS: Diabetics could potentially benefit from a dedicated stent, releasing sirolimus with a lipophilic carrier (amphilimus-formulation). Future trials should confirm the potential benefit of a PF-AES in this population.


Subject(s)
Cardiovascular Agents , Coronary Artery Disease , Diabetes Mellitus , Drug-Eluting Stents , Percutaneous Coronary Intervention , Cardiovascular Agents/adverse effects , Coronary Artery Disease/chemically induced , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Diabetes Mellitus/diagnosis , Diabetes Mellitus/epidemiology , Humans , Percutaneous Coronary Intervention/adverse effects , Polymers , Prosthesis Design , Stents , Treatment Outcome
5.
Am Heart J Plus ; 24: 100227, 2022 Dec.
Article in English | MEDLINE | ID: mdl-38560639

ABSTRACT

Objectives: In an all-comers cohort undergoing percutaneous coronary intervention (PCI), we aimed to assess prevalence of high bleeding risk (HBR) patients and impact of HBR and dual antiplatelet therapy (DAPT) on clinical events. Background: HBR represents a complex subgroup of patients undergoing PCI. Methods: In the ReCre8 trial, patients undergoing PCI were stratified for troponin status and diabetes and randomized to a permanent polymer zotarolimus-eluting- or polymer-free amphilimus-eluting stent. Patients were treated with 12 months (troponin-positive) or one month (troponin-negative) of DAPT. We evaluated clinical outcomes in patients with and without HBR according to the Academic Research Consortium for High Bleeding Risk criteria. Results: From a total of 1488 patients included in this subanalysis, 406 patients (27.3 %) were identified as being at HBR. Among HBR patients, target-lesion failure (TLF) was similar after one year yet was higher after three years (13.3 % vs. 9.1 %; p = 0.013), compared to non-HBR patients. There was no difference in Bleeding Academic Research Consortium (BARC) 3 to 5 bleeding, however BARC 2 to 5 bleeding was higher after three years with 4.9 % vs. 3.0 % (p = 0.037). There were no differences between troponin-positive (12-months DAPT) and -negative (1-month DAPT) HBR patients with respect to ischemic and bleeding outcomes. Conclusions: In this all-comers population of PCI patients, a higher TLF rate among HBR patients at long-term follow-up was found, underlining the complexities involving treatment of HBR patients. We did not observe statistically significant differences in BARC 3 to 5 bleeding between HBR and non-HBR patients regardless of DAPT duration. Clinical trial registration: URL: http://www.clinicaltrials.gov, unique identifier: NCT02328898.

6.
JACC Cardiovasc Interv ; 14(22): 2477-2486, 2021 11 22.
Article in English | MEDLINE | ID: mdl-34794654

ABSTRACT

OBJECTIVES: The aim of this analysis was to assess long-term clinical outcomes of the polymer-free Amphilimus-eluting stent (PF-AES) compared with a latest generation permanent-polymer drug-eluting stent (DES) in an all-comers population. BACKGROUND: PF-AES possess multiple properties improving targeted drug elution without the presence of polymers. Evaluation of long-term clinical performance of PF-AES versus latest generation permanent-polymer DES has not yet been performed in a large randomized trial introducing shortened dual-antiplatelet therapy. METHODS: In this physician-initiated, multicenter, randomized, all-comers trial, patients undergoing percutaneous coronary intervention with implantation of DES were enrolled. Patients were stratified for diabetes and troponin status and randomized to implantation of a permanent-polymer zotarolimus-eluting stent (PP-ZES) or a PF-AES. Dual-antiplatelet therapy duration was 12 months in troponin-positive patients and 1 month in troponin-negative patients. A noninferiority analysis was conducted to compare the 2 arms regarding target lesion failure (TLF) between 1 and 3 years. RESULTS: A total of 1,491 patients were randomized and treated. In this landmark analysis, between 1- and 3-year follow-up, TLF occurred in 35 patients (4.9%) in the PP-ZES arm and 37 PF-AES patients (5.1%). Clinical noninferiority of the PF-AES was confirmed, with a risk difference of 0.2% (upper limit 1-sided 95% CI: 2.2%; Pnoninferiority = 0.0031). CONCLUSIONS: ReCre8 (Randomized "All-Comer" Evaluation of a Permanent Polymer Resolute Integrity Stent Versus a Polymer Free Cre8 Stent) is the first randomized, multicenter trial with a head-to-head comparison of PP-ZES compared with PF-AES to investigate clinical outcomes of these new-generation DES in an all-comers population with long-term follow-up. On the basis of the present results, PF-AES are clinically noninferior to PP-ZES regarding TLF between 1 and 3 years. (Randomized "All-Comer" Evaluation of a Permanent Polymer Resolute Integrity Stent Versus a Polymer Free Cre8 Stent; NCT02328898).


Subject(s)
Cardiovascular Agents , Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Cardiovascular Agents/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Humans , Percutaneous Coronary Intervention/adverse effects , Polymers , Prosthesis Design , Risk Factors , Time Factors , Treatment Outcome
7.
N Engl J Med ; 383(15): 1447-1457, 2020 10 08.
Article in English | MEDLINE | ID: mdl-32865376

ABSTRACT

BACKGROUND: The effect of single as compared with dual antiplatelet treatment on bleeding and thromboembolic events after transcatheter aortic-valve implantation (TAVI) in patients who do not have an indication for long-term anticoagulation has not been well studied. METHODS: In a randomized, controlled trial, we assigned a subgroup of patients who were undergoing TAVI and did not have an indication for long-term anticoagulation, in a 1:1 ratio, to receive aspirin alone or aspirin plus clopidogrel for 3 months. The two primary outcomes were all bleeding (including minor, major, and life-threatening or disabling bleeding) and non-procedure-related bleeding over a period of 12 months. Most bleeding at the TAVI puncture site was counted as non-procedure-related. The two secondary outcomes were a composite of death from cardiovascular causes, non-procedure-related bleeding, stroke, or myocardial infarction (secondary composite 1) and a composite of death from cardiovascular causes, ischemic stroke, or myocardial infarction (secondary composite 2) at 1 year, with both outcomes tested sequentially for noninferiority (noninferiority margin, 7.5 percentage points) and superiority. RESULTS: A total of 331 patients were assigned to receive aspirin alone and 334 were assigned to receive aspirin plus clopidogrel. A bleeding event occurred in 50 patients (15.1%) receiving aspirin alone and in 89 (26.6%) receiving aspirin plus clopidogrel (risk ratio, 0.57; 95% confidence interval [CI], 0.42 to 0.77; P = 0.001). Non-procedure-related bleeding occurred in 50 patients (15.1%) and 83 patients (24.9%), respectively (risk ratio, 0.61; 95% CI, 0.44 to 0.83; P = 0.005). A secondary composite 1 event occurred in 76 patients (23.0%) receiving aspirin alone and in 104 (31.1%) receiving aspirin plus clopidogrel (difference, -8.2 percentage points; 95% CI for noninferiority, -14.9 to -1.5; P<0.001; risk ratio, 0.74; 95% CI for superiority, 0.57 to 0.95; P = 0.04). A secondary composite 2 event occurred in 32 patients (9.7%) and 33 patients (9.9%), respectively (difference, -0.2 percentage points; 95% CI for noninferiority, -4.7 to 4.3; P = 0.004; risk ratio, 0.98; 95% CI for superiority, 0.62 to 1.55; P = 0.93). A total of 44 patients (13.3%) and 32 (9.6%), respectively, received oral anticoagulation during the trial. CONCLUSIONS: Among patients undergoing TAVI who did not have an indication for oral anticoagulation, the incidence of bleeding and the composite of bleeding or thromboembolic events at 1 year were significantly less frequent with aspirin than with aspirin plus clopidogrel administered for 3 months. (Funded by the Netherlands Organization for Health Research and Development; POPular TAVI EU Clinical Trials Register number, 2013-003125-28; ClinicalTrials.gov number, NCT02247128.).


Subject(s)
Aspirin/therapeutic use , Clopidogrel/therapeutic use , Hemorrhage/chemically induced , Platelet Aggregation Inhibitors/therapeutic use , Thrombosis/prevention & control , Transcatheter Aortic Valve Replacement , Administration, Oral , Aged , Aged, 80 and over , Aspirin/adverse effects , Cardiovascular Diseases/epidemiology , Cardiovascular Diseases/mortality , Clopidogrel/adverse effects , Drug Therapy, Combination , Female , Hemorrhage/epidemiology , Humans , Incidence , Male , Platelet Aggregation Inhibitors/adverse effects , Postoperative Period , Thrombosis/epidemiology
8.
JACC Cardiovasc Interv ; 13(14): 1697-1705, 2020 07 27.
Article in English | MEDLINE | ID: mdl-32703593

ABSTRACT

OBJECTIVES: This study sought to compare next-generation cobalt-chromium-based titanium-nitride-oxide (TiNO)-coated stents with a platinum-chromium-based biodegradable polymer everolimus-eluting stent (EES) in patients with acute coronary syndrome (ACS). BACKGROUND: Previous generation TiNO-coated stents showed acceptable performance in patients with ACS. METHODS: In a multicenter, randomized trial, we randomly assigned 1,491 ACS patients (2:1) to receive either a TiNO-coated stent (n = 989) or EES (n = 502). The primary endpoint was the rate of a composite of cardiac death, myocardial infarction (MI), or ischemia-driven target lesion revascularization at 12-month follow-up. The co-primary endpoint was a composite of cardiac death, MI, or major bleeding at 18 months. RESULTS: A primary endpoint event occurred in 6.3% of patients in the TiNO-coated stent group versus in 7.0% in the EES group (hazard ratio: 0.93; 95% confidence interval: 0.71 to 1.22; p = 0.66 for superiority; p < 0.001 for noninferiority). A co-primary endpoint event occurred in 3.7% of the patients in the TiNO group and in 7.8% in the EES group (hazard ratio: 0.64; 95% confidence interval: 0.51 to 0.80; p = 0.001). TiNO-coated stents were associated with lower rates of cardiac death (0.6% vs. 2.6%; p = 0.002) and MI (2.2% vs. 5.0%; p = 0.007) at 18 months of follow-up. Rates of target lesion revascularization were not significantly different at 18 months (5.8% vs. 4.4%; p = 0.27). CONCLUSIONS: In patients with ACS, cobalt-chromium-based TiNO-coated stents were noninferior to platinum-chromium-based biodegradable polymer EES for major cardiac events at 12 months, and were superior for the co-primary endpoint of cardiac death, MI, and bleeding at 18 months. (Comparison of Titanium-Nitride-Oxide-Coated Bio-Active-Stent (Optimax™) to the Drug (Everolimus) -Eluting Stent (Synergy™) in Acute Coronary Syndrome [TIDES-ACS]; NCT02049229).


Subject(s)
Acute Coronary Syndrome/therapy , Cardiovascular Agents/administration & dosage , Drug-Eluting Stents , Everolimus/administration & dosage , Percutaneous Coronary Intervention/instrumentation , Titanium , Acute Coronary Syndrome/diagnostic imaging , Acute Coronary Syndrome/mortality , Aged , Cardiovascular Agents/adverse effects , Europe , Everolimus/adverse effects , Female , Hemorrhage/etiology , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prosthesis Design , Time Factors , Treatment Outcome
9.
N Engl J Med ; 382(18): 1696-1707, 2020 04 30.
Article in English | MEDLINE | ID: mdl-32223116

ABSTRACT

BACKGROUND: The roles of anticoagulation alone or with an antiplatelet agent after transcatheter aortic-valve implantation (TAVI) have not been well studied. METHODS: We performed a randomized trial of clopidogrel in patients undergoing TAVI who were receiving oral anticoagulation for appropriate indications. Patients were assigned before TAVI in a 1:1 ratio not to receive clopidogrel or to receive clopidogrel for 3 months. The two primary outcomes were all bleeding and non-procedure-related bleeding over a period of 12 months. Procedure-related bleeding was defined as Bleeding Academic Research Consortium type 4 severe bleeding, and therefore most bleeding at the puncture site was counted as non-procedure-related. The two secondary outcomes were a composite of death from cardiovascular causes, non-procedure-related bleeding, stroke, or myocardial infarction at 12 months (secondary composite 1) and a composite of death from cardiovascular causes, ischemic stroke, or myocardial infarction (secondary composite 2), both tested for noninferiority (noninferiority margin, 7.5 percentage points) and superiority. RESULTS: Bleeding occurred in 34 of the 157 patients (21.7%) receiving oral anticoagulation alone and in 54 of the 156 (34.6%) receiving oral anticoagulation plus clopidogrel (risk ratio, 0.63; 95% confidence interval [CI], 0.43 to 0.90; P = 0.01); most bleeding events were at the TAVI access site. Non-procedure-related bleeding occurred in 34 patients (21.7%) and in 53 (34.0%), respectively (risk ratio, 0.64; 95% CI, 0.44 to 0.92; P = 0.02). Most bleeding occurred in the first month and was minor. A secondary composite 1 event occurred in 49 patients (31.2%) receiving oral anticoagulation alone and in 71 (45.5%) receiving oral anticoagulation plus clopidogrel (difference, -14.3 percentage points; 95% CI for noninferiority, -25.0 to -3.6; risk ratio, 0.69; 95% CI for superiority, 0.51 to 0.92). A secondary composite 2 event occurred in 21 patients (13.4%) and in 27 (17.3%), respectively (difference, -3.9 percentage points; 95% CI for noninferiority, -11.9 to 4.0; risk ratio, 0.77; 95% CI for superiority, 0.46 to 1.31). CONCLUSIONS: In patients undergoing TAVI who were receiving oral anticoagulation, the incidence of serious bleeding over a period of 1 month or 1 year was lower with oral anticoagulation alone than with oral anticoagulation plus clopidogrel. (Funded by the Netherlands Organization for Health Research and Development; POPular TAVI EU Clinical Trials Register number, 2013-003125-28; ClinicalTrials.gov number, NCT02247128.).


Subject(s)
Anticoagulants/therapeutic use , Clopidogrel/therapeutic use , Hemorrhage/chemically induced , Platelet Aggregation Inhibitors/therapeutic use , Transcatheter Aortic Valve Replacement , Administration, Oral , Aged , Aged, 80 and over , Anticoagulants/adverse effects , Cardiovascular Diseases/epidemiology , Cardiovascular Diseases/mortality , Clopidogrel/adverse effects , Drug Therapy, Combination , Hemorrhage/epidemiology , Humans , Incidence , Kaplan-Meier Estimate , Male , Platelet Aggregation Inhibitors/adverse effects , Transcatheter Aortic Valve Replacement/adverse effects
10.
Circulation ; 139(1): 67-77, 2019 01 02.
Article in English | MEDLINE | ID: mdl-30586704

ABSTRACT

BACKGROUND: Polymer-free amphilimus-eluting stents (PF-AES) represent a novel elution technology in the current era of drug-eluting stents. The clinical safety and efficacy of PF-AES as compared with latest-generation permanent-polymer zotarolimus-eluting stents (PP-ZES) have not yet been investigated in a large randomized trial. METHODS: In this physician-initiated, prospective, multicenter, randomized, noninferiority trial, an all-comers population requiring percutaneous coronary intervention was enrolled across 3 European sites. Randomization (1:1 ratio) to PP-ZES or PF-AES was performed after stratification for troponin status and diabetes mellitus. In both treatment arms, troponin-positive patients were planned for 12-month dual antiplatelet therapy, whereas troponin-negative patients were planned for 1-month dual antiplatelet therapy. Outcome assessors were blinded to the allocated treatment. The device-oriented primary end point of target-lesion failure was defined as cardiac death, target-vessel myocardial infarction, or target-lesion revascularization at 12-months as analyzed by modified intention-to-treat (80% power, and a 3.5% noninferiority margin). RESULTS: In total, 1502 patients were randomized and 1491 treated with the assigned stent and available for follow-up. The primary end point occurred in 42 (5.6%) of the 744 patients receiving PP-ZES versus 46 (6.2%) of the 747 patients receiving PF-AES. PF-AES were clinically noninferior to PP-ZES (risk difference, 0.5%; upper limit 1-sided 95% confidence interval, 2.6%; Pnoninferiority=0.0086). Cardiac death occurred in 10 (1.3%) versus 10 patients (1.3%; P value for difference, 1.00), target-vessel myocardial infarction occurred in 18 (2.4%) versus 17 patients (2.3%; P value for difference, 0.87), and target-lesion revascularization occurred in 22 (2.9%) versus 20 patients (2.6%; P value for difference, 0.75) for PF-AES as compared with PP-ZES. Overall, definite or probable stent thrombosis occurred in 1.0%. CONCLUSIONS: PF-AES were noninferior to PP-ZES regarding target-lesion failure at 12 months. Findings regarding the secondary end point and prespecified subgroups were generally consistent with that of the primary end point. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02328898.


Subject(s)
Acute Coronary Syndrome/therapy , Angina, Stable/therapy , Angina, Unstable/therapy , Cardiovascular Agents/administration & dosage , Coronary Artery Disease/therapy , Drug-Eluting Stents , Myocardial Infarction/therapy , Percutaneous Coronary Intervention/instrumentation , Polymers/chemistry , Sirolimus/analogs & derivatives , Acute Coronary Syndrome/diagnosis , Acute Coronary Syndrome/mortality , Aged , Angina, Stable/diagnosis , Angina, Stable/mortality , Angina, Unstable/diagnosis , Angina, Unstable/mortality , Cardiovascular Agents/adverse effects , Coronary Artery Disease/diagnosis , Coronary Artery Disease/mortality , Coronary Thrombosis/etiology , Europe , Female , Humans , Male , Middle Aged , Myocardial Infarction/diagnosis , Myocardial Infarction/mortality , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prospective Studies , Prosthesis Design , Risk Factors , Sirolimus/administration & dosage , Sirolimus/adverse effects , Time Factors , Treatment Outcome
11.
J Cardiovasc Med (Hagerstown) ; 19(10): 564-570, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30124545

ABSTRACT

AIMS: Late stent thrombosis and delayed vessel wall healing remain an important issue in coronary vessels treated with drug-eluting stents (DES), especially when long-vessel segments need to be covered, like in chronic total occlusions (CTO). Avoiding polymer use to avoid chronic inflammatory responses is a potential solution to reduce target vessel failure (TVF). We aimed to validate the clinical safety and efficacy at 1 year of the polymer-free Cre8 DES vs. nonpolymer-free DES for the percutaneous treatment of CTO. METHODS: Between September 2011 and August 2016, patients were prospectively enrolled in three CTO centres. The primary endpoint was major adverse cardiac and cerebrovascular events (MACCE), including cardiac death, any myocardial infarction, stent thrombosis, TVF and target vessel revascularization. RESULTS: A total of 102 Cre8 and 133 non-Cre8 patients were enrolled. At 1 year, a low cumulative MACCE was observed in the Cre8 group (6.9%, respectively). Moreover, a numerical trend towards better MACCE was observed in the Cre8 group vs. the non-Cre8 group (6.9 vs. 14.3%; P = 0.065). The clinically driven TVF rate was not statistically different between Cre8 and non-Cre8 patients (6.9 vs. 9.8%; P = 0.373). A borderline significant difference regarding mortality was observed in favour of Cre8 patients (0 vs. 3.8%; P = 0.049). CONCLUSION: Low rates of MACCE and TVF up to 1 year were observed in the Cre8 group, supportive of the use of polymer-free DES for lesions with high complexity.


Subject(s)
Cardiovascular Agents/administration & dosage , Coronary Occlusion/surgery , Drug-Eluting Stents , Percutaneous Coronary Intervention/instrumentation , Sirolimus/analogs & derivatives , Sirolimus/administration & dosage , Aged , Cardiovascular Agents/adverse effects , Chronic Disease , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/mortality , Europe , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prosthesis Design , Retrospective Studies , Risk Factors , Sirolimus/adverse effects , Time Factors , Treatment Outcome
12.
Catheter Cardiovasc Interv ; 92(3): 488-496, 2018 09 01.
Article in English | MEDLINE | ID: mdl-29068171

ABSTRACT

OBJECTIVES: To assess the safety and efficacy of everolimus-eluting bioresorbable scaffolds (BRS) in the treatment of chronic total occlusions (CTO) using noninvasive multislice computed tomography (MSCT) angiography at one-year follow-up. BACKGROUND: Current evidence regarding the safety and efficacy of BRS for the percutaneous treatment of CTO is limited. METHODS: Between September 2013 and January 2016, patients who received one or more ABSORB BRSs were included at three centers. MSCT (including quantitative analysis) and clinical follow-up were performed at one year. RESULTS: Forty-one CTO patients were included. Mean age was 60 ± 11 years and the majority was male (83%). Average Japanese CTO (J-CTO) score was 0.9 ± 0.9. Seventy-one BRS were implanted in total with, on average, 1.7 ± 0.8 scaffolds/patient, and a total length of 43 ± 20 mm and diameter of 3.1 ± 0.4 mm. One noncardiac death took place. MSCT angiography was performed in 34 (83%) patients: all scaffolds were patent, except in one patient, in whom a patent target vessel was present on subsequent diagnostic angiography. MSCT quality was sufficient for quantitative analyses in 27 patients (46 scaffolds): median reference versus scaffold minimal lumen diameter and minimal lumen area were measured, and showed a small difference of 0.1 mm (-0.2-0.4) (lumen diameter stenosis = 3.0%) and 0.5 mm2 (-1.0-2.0) (lumen area stenosis = 4.2%). CONCLUSIONS: The low number of events and high patency rate at 1 year are encouraging the further use of the ABSORB scaffold for CTOs with low J-CTO score. Noninvasive MSCT angiography is a valid tool to assess scaffold patency, although its image resolution limits the use for quantitative measurements.


Subject(s)
Absorbable Implants , Computed Tomography Angiography/methods , Coronary Angiography/methods , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/therapy , Coronary Vessels/diagnostic imaging , Multidetector Computed Tomography/methods , Percutaneous Coronary Intervention/instrumentation , Aged , Cardiovascular Agents/administration & dosage , Chronic Disease , Coated Materials, Biocompatible , Coronary Occlusion/physiopathology , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Restenosis/physiopathology , Coronary Vessels/physiopathology , Europe , Everolimus/administration & dosage , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Predictive Value of Tests , Prospective Studies , Prosthesis Design , Reproducibility of Results , Time Factors , Treatment Outcome , Vascular Patency
13.
Acta Cardiol ; 73(5): 427-436, 2018 Oct.
Article in English | MEDLINE | ID: mdl-29183248

ABSTRACT

Background: Important developments in materials, devices, and techniques have improved outcomes of chronic total occlusion (CTO) percutaneous coronary intervention (PCI), and resulted in a growing interest in CTO-PCI. The Belgian Working Group on Chronic Total Occlusions (BWGCTO) working group aims to assess the evolution within the CTO-PCI landscape over the next years. Methods: From May 2016 onwards, patients undergoing CTO-PCI were included in the BWGCTO registry by 15 centres in Belgium and Luxemburg. Baseline, angiographic, and procedural data were collected. Here, we report on the one-year in-hospital outcomes. Results: Over the course of one year, 411 procedures in 388 patients were included with a mean age of 64 ± 11 years. The majority were male (81%). Relatively complex CTOs were treated (Japanese CTO score =2.2 ± 1.2) with a high procedure success rate (82%). Patient- and lesion-wise success rates were 83 and 85%, respectively. Major adverse in-hospital events were acceptably low (3.4%). Antegrade wire escalation technique was applied most frequently (82%). On the other hand, antegrade dissection and re-entry and retrograde strategies were more frequently applied in higher volume centres and successful for lesions with higher complexity. Conclusion: Satisfactory procedural outcomes and a low rate of adverse events were obtained in a complex CTO population, treated by operators with variable experience levels. Antegrade wire escalation was the preferred strategy, regardless of operator volume.


Subject(s)
Percutaneous Coronary Intervention , Belgium , Female , Humans , Luxembourg , Male , Middle Aged , Registries , Treatment Outcome
14.
Catheter Cardiovasc Interv ; 91(3): 410-416, 2018 02 15.
Article in English | MEDLINE | ID: mdl-28544782

ABSTRACT

BACKGROUND: Amphilimus sirolimus-eluting stents (A-SES) represent a novel elution technology in the current era of drug-eluting stents with promising results in patients with diabetes mellitus. At present no large trial has been designed to evaluate clinical outcomes of A-SES as compared to new-generation drug-eluting stents in unselected patients. Accordingly, we designed this trial to evaluate clinical noninferiority of A-SES as compared with zotarolimus-eluting stents (ZES) in a real-world, all-comers setting. STUDY DESIGN: ReCre8 is a prospective multicenter randomized clinical trial evaluating the clinical outcomes of A-SES as compared with ZES in all-comers requiring percutaneous coronary intervention. Patients are randomized 1:1 to receive either A-SES or ZES. On-site block-randomization is stratified by diabetes mellitus, and troponin status to perform prespecified subanalyses. Patients receive 1-month of dual antiplatelet therapy (DAPT) when troponin-negative, or 12-months of DAPT when troponin-positive. The primary endpoint is target-lesion failure at 1-year follow-up. A total of 1,532 patients will be enrolled to demonstrate clinical noninferiority of A-SES with at least 80% power, a noninferiority margin of 3.5% and a type-I-error of 0.05. CONCLUSIONS: ReCre8 (NCT02328898) is the first randomized multicenter trial with a head-to-head comparison of A-SES as compared with ZES to investigate the clinical safety and efficacy of these new-generation DES in a real-world, all-comers population.


Subject(s)
Cardiovascular Agents/administration & dosage , Coronary Artery Disease/surgery , Drug-Eluting Stents , Percutaneous Coronary Intervention/instrumentation , Sirolimus/analogs & derivatives , Coronary Artery Disease/diagnostic imaging , Equivalence Trials as Topic , Humans , Multicenter Studies as Topic , Percutaneous Coronary Intervention/adverse effects , Prospective Studies , Prosthesis Design , Randomized Controlled Trials as Topic , Risk Factors , Sirolimus/administration & dosage , Time Factors , Treatment Outcome
15.
EuroIntervention ; 12(11): e1413-e1419, 2016 Dec 10.
Article in English | MEDLINE | ID: mdl-27934611

ABSTRACT

AIMS: Our aim was to assess the clinical outcomes of the Direct Flow Medical Transcatheter Aortic Valve System (DFM-TAVS), when used in routine clinical practice. METHODS AND RESULTS: This is a prospective, open-label, multicentre, post-market registry of patients treated with DFM-TAVS according to approved commercial indications. Echocardiographic and angiographic data were evaluated by an independent core laboratory and adverse events were adjudicated and classified according to VARC-2 criteria by an independent clinical events committee. The primary endpoint was freedom from all-cause mortality at 30 days post procedure. Secondary endpoints included procedural, early safety and efficacy endpoints at 30 days. Two hundred and fifty patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) with the DFM-TAVS were enrolled in 21 European centres. The primary endpoint, freedom from all-cause mortality at 30 days, was met in 98% (245/250) of patients. Device success was 83.8%. Moderate or severe aortic regurgitation was reported in 3% of patients, and none/trace regurgitation in 73% of patients. Post-procedural permanent pacemaker implantation was performed in 30 patients (12.0%). CONCLUSIONS: The DFM-TAVS was associated with good short-term outcomes in this real-world registry. The low pacemaker and aortic regurgitation rates confirm the advantages of this next-generation transcatheter heart valve (THV).


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve Insufficiency/etiology , Cardiac Catheterization , Female , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/methods , Humans , Male , Prospective Studies , Registries , Risk Factors , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
16.
EuroIntervention ; 11(11): e1314-20, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26865450

ABSTRACT

AIMS: Our aim was to assess the performance of the Direct Flow Medical (DFM) repositionable and retrievable transcatheter aortic valve implantation (TAVI) system in high-risk patients with severe aortic stenosis. METHODS AND RESULTS: One hundred and five consecutive high-risk patients with severe aortic stenosis undergoing TAVI with the DFM prosthesis were enrolled in six high-volume TAVI centres in Germany, Italy, The Netherlands, Belgium, and Luxembourg. The "inner curve" technique was systematically used in all patients. The primary endpoint was all-cause mortality at 30 days of clinical follow-up. Secondary endpoints for the same time frame were: (i) VARC-2-defined patient safety; and (ii) VARC-2-defined device success. The primary endpoint of all-cause mortality at 30 days was met in 1.9% (two patients). The VARC-2-defined device success rate was 98.1%. The combined patient safety endpoint was met in 88.6%. Residual moderate aortic regurgitation was observed in 1.9% (two patients). Permanent pacemaker implantation due to post-procedural persistent advanced atrioventricular block was performed in 9.5% (10 patients). CONCLUSIONS: In a multicentre, real-world clinical setting of high-risk patients with severe aortic stenosis, a repositionable and retrievable TAVI system was effective and safe in the short-term follow-up.


Subject(s)
Aortic Valve Stenosis/therapy , Aortic Valve/surgery , Cardiac Catheterization , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Cardiac Catheterization/adverse effects , Female , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/methods , Humans , Male , Risk Factors , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...