Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 51
Filter
1.
Einstein (Sao Paulo) ; 22: eAE0780, 2024.
Article in English | MEDLINE | ID: mdl-38865568

ABSTRACT

Implementing a structured COVID-19 lung ultrasound system, using COVID-RADS standardization. This case series exams revealed correlations between ultrasonographic and tomographic findings. Ventilatory assessments showed that higher categories required second-line oxygen. This replicable tool will aid in screening and predicting disease severity beyond the pandemic. OBJECTIVE: We aimed to share our experience in implementing a structured system for COVID-19 lung findings, elucidating key aspects of the lung ultrasound score to facilitate its standardized clinical use beyond the pandemic scenario. METHODS: Using a scoring system to classify the extent of lung involvement, we retrospectively analyzed the ultrasound reports performed in our institution according to COVID-RADS standardization. RESULTS: The study included 69 thoracic ultrasound exams, with 27 following the protocol. The majority of patients were female (52%), with ages ranging from 1 to 96 years and an average of 56 years. Classification according to COVID-RADS was as follows: 11.1% in category 0, 37% in category 1, 44.4% in category 2, and 7.4% in category 3. Ground-glass opacities on tomography correlated with higher COVID-RADS scores (categories 2 and 3) in 82% of cases. Ventilatory assessment revealed that 50% of cases in higher COVID-RADS categories (2 and 3) required second-line oxygen supplementation, while none of the cases in lower categories (0 and 1) utilized this support. CONCLUSION: Lung ultrasound has been widely utilized as a diagnostic tool owing to its availability and simplicity of application. In the context of the pandemic emergency, a pressing need for a focused and easily applicable assessment arose. The structured reporting system, incorporating ultrasound findings for stratification, demonstrated ease of replicability. This system stands as a crucial tool for screening, predicting severity, and aiding in medical decisions, even in a non-pandemic context. Lung ultrasound enables precise diagnosis and ongoing monitoring of the disease. Ultrasound is an effective tool for assessing pulmonary findings in COVID-19. Structured reports enhance communication and are easily reproducible.


Subject(s)
COVID-19 , Lung , Ultrasonography , Humans , COVID-19/diagnostic imaging , Female , Ultrasonography/methods , Male , Retrospective Studies , Middle Aged , Aged , Child , Adolescent , Adult , Lung/diagnostic imaging , Aged, 80 and over , Young Adult , Infant , Child, Preschool , Pandemics , SARS-CoV-2 , Tomography, X-Ray Computed/methods , Severity of Illness Index
4.
Einstein (Säo Paulo) ; 22: eAE0780, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1557723

ABSTRACT

ABSTRACT Objective We aimed to share our experience in implementing a structured system for COVID-19 lung findings, elucidating key aspects of the lung ultrasound score to facilitate its standardized clinical use beyond the pandemic scenario. Methods Using a scoring system to classify the extent of lung involvement, we retrospectively analyzed the ultrasound reports performed in our institution according to COVID-RADS standardization. Results The study included 69 thoracic ultrasound exams, with 27 following the protocol. The majority of patients were female (52%), with ages ranging from 1 to 96 years and an average of 56 years. Classification according to COVID-RADS was as follows: 11.1% in category 0, 37% in category 1, 44.4% in category 2, and 7.4% in category 3. Ground-glass opacities on tomography correlated with higher COVID-RADS scores (categories 2 and 3) in 82% of cases. Ventilatory assessment revealed that 50% of cases in higher COVID-RADS categories (2 and 3) required second-line oxygen supplementation, while none of the cases in lower categories (0 and 1) utilized this support. Conclusion Lung ultrasound has been widely utilized as a diagnostic tool owing to its availability and simplicity of application. In the context of the pandemic emergency, a pressing need for a focused and easily applicable assessment arose. The structured reporting system, incorporating ultrasound findings for stratification, demonstrated ease of replicability. This system stands as a crucial tool for screening, predicting severity, and aiding in medical decisions, even in a non-pandemic context.

8.
Einstein (Sao Paulo) ; 20: eAO6935, 2022.
Article in English | MEDLINE | ID: mdl-35792758

ABSTRACT

OBJECTIVE: To stratify ultrasound samples in a pediatric population undergoing evaluation for acute appendicitis to examine the variability in cecal appendix diameter, in different age groups, and to determine whether there is a prevalent value for each age group. METHODS: A retrospective cross-sectional study with 196 children aged 0 to 15 years. Data were extracted from reports of ultrasound examinations carried out between 2008 and 2015. Children with sonographic diagnosis of appendicitis or other signs of periappendiceal inflammation were excluded. RESULTS: The evaluation of the anteroposterior measurement of the cecal appendix revealed a mean diameter of 4.14mm (standard deviation: 0.93mm; 95%CI: 3.86-4.14). Cecal appendix diameter did not differ significant between age groups. CONCLUSION: Evaluation of the anteroposterior diameter of the cecal appendix in centimeters in a sample of 196 children aged 0 to15 years revealed a mean diameter of 4.14mm (standard deviation, 0.93mm. There were no significant differences in cecal appendix diameter following stratification by age. Results indicate a single value can be adopted for mean cecal appendix diameter in pediatric populations.


Subject(s)
Appendicitis , Appendix , Appendicitis/diagnostic imaging , Appendix/diagnostic imaging , Child , Cross-Sectional Studies , Humans , Retrospective Studies , Ultrasonography
9.
Einstein (Sao Paulo) ; 20: eAO6747, 2022.
Article in English | MEDLINE | ID: mdl-35584446

ABSTRACT

OBJECTIVE: To determine whether the size of thyroid nodules in ACR-TIRADS ultrasound categories 3 and 4 is correlated with the Bethesda cytopathology classification. METHODS: Thyroid nodules (566) subclassified as ACR-TIRADS 3 or 4 were divided into three size categories according to American Thyroid Association guidelines. The frequency of different Bethesda categories in each size range within ACR-TIRADS 3 and 4 classifications was analyzed. RESULTS: Most nodules in both ACR-TIRADS classifications fell in the Bethesda 2 category, regardless of size (90.8% and 68.6%, ACR-TIRADS 3 and 4 respectively). The prevalence of Bethesda 6 nodules in the ACR-TIRADS 4 group was 14 times higher than in the ACR-TIRADS 3 group. There were no significant differences between nodule size and fine needle aspiration biopsy classification in any of the ACR-TIRADS categories. CONCLUSION: Size does not appear to be an important criterion for indication of fine needle aspiration biopsy in thyroid nodules with a high suspicion of malignancy on ultrasound examination.


Subject(s)
Thyroid Neoplasms , Thyroid Nodule , Biopsy, Fine-Needle , Humans , Retrospective Studies , Thyroid Neoplasms/pathology , Thyroid Nodule/diagnostic imaging , Thyroid Nodule/pathology , Ultrasonography , United States
10.
Einstein (Sao Paulo) ; 20: eRC5584, 2022.
Article in English | MEDLINE | ID: mdl-35170708

ABSTRACT

A 2-year-old female patient, admitted in the emergency room, presented diarrhea for 5 days and bloody stools in the last 24 hours. Physical examination revealed no significant findings. Ultrasound was initially performed, showing an elongated, well delimited and solid mass occupying since right hypocondrium until left iliac fossa, displacing adjacent structures. In sequence, magnetic resonance imaging was performed for confirmation of findings suggestive of omentum lipoma. After 1 week, the surgical resection was performed by videolaparoscopic acess. During 2-year follow-up, there was no sign of recurrence.


Subject(s)
Lipoma , Omentum , Child , Child, Preschool , Female , Humans , Lipoma/diagnostic imaging , Lipoma/surgery , Magnetic Resonance Imaging , Omentum/diagnostic imaging , Omentum/surgery , Ultrasonography
11.
Einstein (Säo Paulo) ; 20: eAO6935, 2022. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1384774

ABSTRACT

ABSTRACT Objective To stratify ultrasound samples in a pediatric population undergoing evaluation for acute appendicitis to examine the variability in cecal appendix diameter, in different age groups, and to determine whether there is a prevalent value for each age group. Methods A retrospective cross-sectional study with 196 children aged 0 to 15 years. Data were extracted from reports of ultrasound examinations carried out between 2008 and 2015. Children with sonographic diagnosis of appendicitis or other signs of periappendiceal inflammation were excluded. Results The evaluation of the anteroposterior measurement of the cecal appendix revealed a mean diameter of 4.14mm (standard deviation: 0.93mm; 95%CI: 3.86-4.14). Cecal appendix diameter did not differ significant between age groups. Conclusion Evaluation of the anteroposterior diameter of the cecal appendix in centimeters in a sample of 196 children aged 0 to15 years revealed a mean diameter of 4.14mm (standard deviation, 0.93mm. There were no significant differences in cecal appendix diameter following stratification by age. Results indicate a single value can be adopted for mean cecal appendix diameter in pediatric populations.

12.
Einstein (Säo Paulo) ; 20: eAO6747, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1375324

ABSTRACT

ABSTRACT Objective To determine whether the size of thyroid nodules in ACR-TIRADS ultrasound categories 3 and 4 is correlated with the Bethesda cytopathology classification. Methods Thyroid nodules (566) subclassified as ACR-TIRADS 3 or 4 were divided into three size categories according to American Thyroid Association guidelines. The frequency of different Bethesda categories in each size range within ACR-TIRADS 3 and 4 classifications was analyzed. Results Most nodules in both ACR-TIRADS classifications fell in the Bethesda 2 category, regardless of size (90.8% and 68.6%, ACR-TIRADS 3 and 4 respectively). The prevalence of Bethesda 6 nodules in the ACR-TIRADS 4 group was 14 times higher than in the ACR-TIRADS 3 group. There were no significant differences between nodule size and fine needle aspiration biopsy classification in any of the ACR-TIRADS categories. Conclusion Size does not appear to be an important criterion for indication of fine needle aspiration biopsy in thyroid nodules with a high suspicion of malignancy on ultrasound examination.

13.
Einstein (Säo Paulo) ; 20: eRC5584, 2022. graf
Article in English | LILACS | ID: biblio-1360405

ABSTRACT

ABSTRACT A 2-year-old female patient, admitted in the emergency room, presented diarrhea for 5 days and bloody stools in the last 24 hours. Physical examination revealed no significant findings. Ultrasound was initially performed, showing an elongated, well delimited and solid mass occupying since right hypocondrium until left iliac fossa, displacing adjacent structures. In sequence, magnetic resonance imaging was performed for confirmation of findings suggestive of omentum lipoma. After 1 week, the surgical resection was performed by videolaparoscopic acess. During 2-year follow-up, there was no sign of recurrence.


Subject(s)
Humans , Female , Child, Preschool , Child , Omentum/surgery , Omentum/diagnostic imaging , Lipoma/surgery , Lipoma/diagnostic imaging , Magnetic Resonance Imaging , Ultrasonography
14.
Einstein (Sao Paulo) ; 18: eRC5415, 2020.
Article in English, Portuguese | MEDLINE | ID: mdl-33295432

ABSTRACT

A 34-years-old pregnant woman admitted in the emergency unit complaining about worsening right iliac fossa pain for 2 days. Acute appendicitis was the suspected diagnosis. Laboratory exams were ordered and results were within normal limits for infectious and inflammatory aspects. Ultrasound scan revealed a pregnancy in course without alterations and a thickness of the appendix wall without inflammatory signs in the surrounding tissue. Because the suspicion of acute appendicitis remained, a magnetic resonance was done and confirmed the diagnosis of a cecal appendix lipomatosis.


Subject(s)
Appendicitis , Appendix , Lipomatosis , Acute Disease , Adult , Appendicitis/diagnostic imaging , Appendix/diagnostic imaging , Diagnosis, Differential , Female , Humans , Pregnancy , Ultrasonography
15.
Einstein (Sao Paulo) ; 18: eAO5576, 2020.
Article in English, Portuguese | MEDLINE | ID: mdl-33206813

ABSTRACT

OBJECTIVE: To evaluate anatomic factors and radiologist's experience in the detection of solid renal masses on ultrasonography. METHODS: We searched for solid renal masses diagnosed on cross-sectional imaging from 2007 to 2017 that also had previous ultrasonography from the past 6 months. The following features were evaluated: nodule size, laterality, location and growth pattern, patient body mass index and radiologist's experience in ultrasound. In surgically resected cases, pathologic reports were evaluated. Unpaired t test and χ2 test were used to evaluate differences among subgroups, using R-statistics. Statistical significance was set at p<0.05. RESULTS: The initial search of renal nodules on cross-sectional imaging resulted in 428 lesions and 266 lesions were excluded. Final cohort included 162 lesions and, of those, 108 (67%) were correctly detected on ultrasonography (Group 1) and 54 (33%) were missed (Group 2). Comparison of Groups 1 and 2 were as follows, respectively: body mass index (27.7 versus 27.1; p=0.496), size (2.58cm versus 1.74cm; p=0.003), laterality (54% versus 59% right sided; p=0.832), location (27% versus 22% upper pole; p=0.869), growth pattern (25% versus 28% endophytic; p=0.131) and radiologist's experience (p=0.300). From surgically resected cases, histology available for Group 1 was clear cell (n=11), papillary (n=15), chromophobe (n=2) renal cell carcinoma, oncocytoma (n=1), and, for Group 2, clear cell (n=7), papillary (n=5) renal cell carcinoma, oncocytoma (n=2), angiomyolipoma, chromophobe renal cell carcinoma, and interstitial pyelonephritis (n=1, each). CONCLUSION: Size was the only significant parameter related to renal nodule detection on ultrasound.


Subject(s)
Carcinoma, Renal Cell , Kidney Neoplasms , Kidney/diagnostic imaging , Ultrasonography , Carcinoma, Renal Cell/diagnostic imaging , Diagnosis, Differential , Humans , Kidney/pathology , Kidney Neoplasms/diagnostic imaging , Radiologists
17.
Eur J Radiol ; 133: 109354, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33099221

ABSTRACT

PURPOSE: To describe our group experience in treatment of benign symptomatic thyroid nodules using radiofrequency ablation technique always associated to routine pre-procedure hydrodissection and under sedation with programmed stop. METHODS: Dual-center, retrospective study conducted between April 2018 and January 2020. A total of 52 symptomatic benign thyroid nodules were treated in 34 patients with ultrasound-guided percutaneous radiofrequency ablation. The technique of choice was moving-shot technique and 100 % patients underwent pre-procedural hydrodissection with 5% glucose solution, plus conscious sedation with programmed stop during procedure. RESULTS: Most nodules were solid or almost completely solid (n = 45, 88.3 % of nodules), followed by cystic composition (n = 4, 7.8 %) and mixed (n = 2, 3.9 %). As for location, most were on the right lobe (n = 29, 56.9 %), followed by the left lobe (n = 17, 33.3 %) and isthmus (n = 5, 9.8 %). The average volume of nodules before ablation was 18.2 ±â€¯20.5 mL. Volumetric reduction rates at one, three, six and twelve months after ablation were 46.6 %, 64.5 %, 76.1 % and 88.8 %, respectively. No complications strictly related to procedure were reported. No more than 5 min were added to total time of ablative treatment considering routine hydrodissection and stop programmed sedation. CONCLUSIONS: Minimally invasive therapies applied to thyroid allow the preservation of healthy thyroid parenchyma and provide a very effective volumetric reduction of symptomatic benign thyroid nodules. Hydrodissection with 5 % glucose solution, conscious sedation and patient stimulation with programmed stop during procedure may provide greater safety to procedure, and, in our experience, could be done routinely in all patients.


Subject(s)
Catheter Ablation , Radiofrequency Ablation , Thyroid Nodule , Humans , Retrospective Studies , Thyroid Nodule/diagnostic imaging , Thyroid Nodule/surgery , Treatment Outcome , Ultrasonography
19.
Int J Cardiol Hypertens ; 6: 100043, 2020 Sep.
Article in English | MEDLINE | ID: mdl-33447769

ABSTRACT

BACKGROUND AND AIMS: Carotid intima-media thickness (cIMT) is a strong predictor of cardiovascular events and associated with metabolic syndrome (MetS). MetS is a cluster of cardiovascular risk factors, but the association structure between specific factors and disease development is not well-established in rural populations. We described the association structure between MetS factors and cIMT in a sample from rural Brazil. METHODS: We studied 1937 participants from the Baependi Heart Study who underwent carotid ultrasound exam. We used ATP-III-2001 for MetS definition and linear mixed-effects models, adjusting by the family structure, to assess independent associations between the cardiovascular risk factors which define MetS and cIMT. RESULTS: The sample's mean age was 46 ± 16y, 61% female, 73% white, mean body-mass-index 26±5 kg/m2, mean cIMT 0.53 ± 0.16 mm, with 35% of the sample classified with MetS. As expected, cIMT demonstrated a linear relationship with increasing age, and cIMT higher values were observed for MetS (0.58 ± 0.16 mm) compared to non-MetS (0.49 ± 0.14 mm). Considering models for cIMT with MetS and all of its factors, we found that blood pressure, glucose and obesity were independently associated with cIMT, but not HDL or triglycerides. CONCLUSIONS: cIMT showed a linear relationship with increasing age. Blood pressure, obesity, and glucose were independently associated with cIMT, but not HDL-cholesterol or triglycerides. In a rural population, hypertension, diabetes and obesity play a more important role than lipids in determining cIMT interindividual variability.

20.
Einstein (Säo Paulo) ; 18: eAO5576, 2020. tab
Article in English | LILACS | ID: biblio-1133778

ABSTRACT

ABSTRACT Objective: To evaluate anatomic factors and radiologist's experience in the detection of solid renal masses on ultrasonography. Methods: We searched for solid renal masses diagnosed on cross-sectional imaging from 2007 to 2017 that also had previous ultrasonography from the past 6 months. The following features were evaluated: nodule size, laterality, location and growth pattern, patient body mass index and radiologist's experience in ultrasound. In surgically resected cases, pathologic reports were evaluated. Unpaired t test and χ2 test were used to evaluate differences among subgroups, using R-statistics. Statistical significance was set at p<0.05. Results: The initial search of renal nodules on cross-sectional imaging resulted in 428 lesions and 266 lesions were excluded. Final cohort included 162 lesions and, of those, 108 (67%) were correctly detected on ultrasonography (Group 1) and 54 (33%) were missed (Group 2). Comparison of Groups 1 and 2 were as follows, respectively: body mass index (27.7 versus 27.1; p=0.496), size (2.58cm versus 1.74cm; p=0.003), laterality (54% versus 59% right sided; p=0.832), location (27% versus 22% upper pole; p=0.869), growth pattern (25% versus 28% endophytic; p=0.131) and radiologist's experience (p=0.300). From surgically resected cases, histology available for Group 1 was clear cell (n=11), papillary (n=15), chromophobe (n=2) renal cell carcinoma, oncocytoma (n=1), and, for Group 2, clear cell (n=7), papillary (n=5) renal cell carcinoma, oncocytoma (n=2), angiomyolipoma, chromophobe renal cell carcinoma, and interstitial pyelonephritis (n=1, each). Conclusion: Size was the only significant parameter related to renal nodule detection on ultrasound.


RESUMO Objetivo: Avaliar os fatores anatômicos e a experiência do radiologista na detecção de massas renais sólidas na ultrassonografia. Métodos: Buscamos massas renais sólidas diagnosticadas em imagens seccionais, de 2007 a 2017, que também tivessem ultrassonografia prévia nos últimos 6 meses. As seguintes características foram avaliadas: tamanho do nódulo, lateralidade, localização e padrão de crescimento, índice de massa corporal do paciente e experiência do radiologista em ultrassonografia. Nos casos com ressecção cirúrgica, os laudos de patologia foram analisados. O teste t não pareado e o teste χ2 foram utilizados para avaliar as diferenças entre os subgrupos, usando R-statistics. A significância estatística foi estabelecida em p<0,05. Resultados: A pesquisa inicial de nódulos renais achados em imagens seccionais resultou em 428 lesões, com 266 exclusões. A coorte final incluiu 162 lesões e, destas, 108 (67%) foram detectadas corretamente na ultrassonografia (Grupo 1), e 54 (33%) não foram identificadas (Grupo 2). A comparação dos Grupos 1 e 2 mostrou índice de massa corporal (27,7 versus 27,1; p=0,496), tamanho (2,58cm versus 1,74cm; p=0,003), lateralidade (54% versus 59% no lado direito; p=0,832), localização (27% versus 22% no polo superior; p=0,869), padrão de crescimento (25% versus 28% endofítico; p=0,131) e experiência do radiologista (p=0,300). A histologia disponível para o Grupo 1 foi carcinoma renal de células claras (n=11), papilar (n=15), cromófobo (n=2), oncocitoma (n=1), e, para o Grupo 2, carcinoma renal de células claras (n=7), papilar (n=5), oncocitoma (n=2), angiomiolipoma, cromófobo e pielonefrite intersticial (n=1, cada). Conclusão: O tamanho foi o único parâmetro significativo relacionado à detecção de nódulos renais no ultrassom.


Subject(s)
Humans , Carcinoma, Renal Cell/diagnostic imaging , Ultrasonography , Kidney/diagnostic imaging , Kidney Neoplasms/diagnostic imaging , Diagnosis, Differential , Radiologists , Kidney/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...