Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Ophthalmol Sci ; 4(5): 100517, 2024.
Article in English | MEDLINE | ID: mdl-38881613

ABSTRACT

Purpose: Knowing the surgical safety of anterior chamber liquid biopsies will support the increased use of proteomics and other molecular analyses to better understand disease mechanisms and therapeutic responses in patients and clinical trials. Manual review of operative notes from different surgeons and procedures in electronic health records (EHRs) is cumbersome, but free-text software tools could facilitate efficient searches. Design: Retrospective case series. Participants: A total of 1418 aqueous humor liquid biopsies from patients undergoing intraocular surgery. Methods: Free-text EHR searches were performed using the Stanford Research Repository cohort discovery tool to identify complications associated with anterior chamber paracentesis and subsequent endophthalmitis. Complications of the surgery unrelated to the biopsy were not reviewed. Main Outcome Measures: Biopsy-associated intraoperative complications and endophthalmitis. Results: A total of 1418 aqueous humor liquid biopsies were performed by 17 experienced surgeons. EHR free-text searches were 100% error-free for surgical complications, >99% for endophthalmitis (<1% false positive), and >93.6% for anesthesia type, requiring manual review for only a limited number of cases. More than 85% of cases were performed under local anesthesia without ocular muscle akinesia. Although the most common indication was cataract (50.1%), other diagnoses included glaucoma, diabetic retinopathy, uveitis, age-related macular degeneration, endophthalmitis, retinitis pigmentosa, and uveal melanoma. A 50- to 100-µL sample was collected in all cases using either a 30-gauge needle or a blunt cannula via a paracentesis. The median follow-up was >7 months. There was only one minor complication (0.07%) identified: a case of a small tear in Descemet membrane without long-term sequelae. No other complications occurred, including other corneal injuries, lens or iris trauma, hyphema, or suprachoroidal hemorrhage. There was no case of postoperative endophthalmitis. Conclusions: Anterior chamber liquid biopsy during intraocular surgery is a safe procedure and may be considered for large-scale collection of aqueous humor samples for molecular analyses. Free-text EHR searches are an efficient approach to reviewing intraoperative procedures. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

2.
Graefes Arch Clin Exp Ophthalmol ; 262(6): 1737-1744, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38206414

ABSTRACT

BACKGROUND: Kabuki Syndrome is a rare and genetically heterogenous condition with both ophthalmic and systemic complications and typical facial features. We detail the macular phenotype in two unrelated patients with Kabuki syndrome due to de novo nonsense variants in KMT2D, one novel. A follow-up of 10 years is reported. Pathogenicity of both de novo nonsense variants is analyzed. METHODS: Four eyes of two young patients were studied by full clinical examination, kinetic perimetry, short wavelength autofluorescence, full field (ff) ERGs, and spectral-domain optical coherence tomography (SD-OCT). One patient had adaptive optic (AO) imaging. Whole exome sequencing was performed in both patients. RESULTS: Both patients had de novo nonsense variants in KMTD2. One patient had c.14843C>G; p. (Ser4948ter) novel variant and the second c.11119C>T; p. (Arg3707ter). Both had a stable Snellen visual acuity of 0.2-0.3. The retinal multimodal imaging demonstrated abnormalities at the fovea in both eyes: hyperreflectivity to blue light and a well-delimited gap-disruption of ellipsoid and interdigitation layer on OCT. The dark area on AO imaging is presumed to be absent for, or with structural change to photoreceptors. The ff ERGs and kinetic visual fields were normal. The foveal findings remained stable over several years. CONCLUSION: Kabuki syndrome-related maculopathy is a distinct loss of photoreceptors at the fovea as shown by multimodal imaging including, for the first time, AO imaging. This report adds to the literature of only one case with maculopathy with two additional macular dystrophies in patients with Kabuki syndrome. Although underestimated, these cases further raise awareness of the potential impact of retinal manifestations of Kabuki syndrome not only among ophthalmologists but also other healthcare professionals involved in the care of patients with this multisystem disorder.


Subject(s)
Abnormalities, Multiple , Electroretinography , Face , Fluorescein Angiography , Hematologic Diseases , Multimodal Imaging , Neoplasm Proteins , Phenotype , Tomography, Optical Coherence , Vestibular Diseases , Visual Acuity , Humans , Vestibular Diseases/genetics , Vestibular Diseases/diagnosis , Vestibular Diseases/physiopathology , Face/abnormalities , Hematologic Diseases/genetics , Hematologic Diseases/diagnosis , Hematologic Diseases/physiopathology , Tomography, Optical Coherence/methods , Abnormalities, Multiple/genetics , Abnormalities, Multiple/diagnosis , Follow-Up Studies , Male , Female , Neoplasm Proteins/genetics , Fluorescein Angiography/methods , DNA-Binding Proteins/genetics , Macular Degeneration/genetics , Macular Degeneration/diagnosis , Macular Degeneration/physiopathology , Neck , Fundus Oculi , DNA/genetics , Exome Sequencing , DNA Mutational Analysis , Macula Lutea/pathology , Time Factors , Adult , Adolescent
3.
J Proteome Res ; 23(2): 511-522, 2024 02 02.
Article in English | MEDLINE | ID: mdl-38171013

ABSTRACT

Minimally invasive liquid biopsies from the eye capture locally enriched fluids that contain thousands of proteins from highly specialized ocular cell types, presenting a promising alternative to solid tissue biopsies. The advantages of liquid biopsies include sampling the eye without causing irreversible functional damage, potentially better reflecting tissue heterogeneity, collecting samples in an outpatient setting, monitoring therapeutic response with sequential sampling, and even allowing examination of disease mechanisms at the cell level in living humans, an approach that we refer to as TEMPO (Tracing Expression of Multiple Protein Origins). Liquid biopsy proteomics has the potential to transform molecular diagnostics and prognostics and to assess disease mechanisms and personalized therapeutic strategies in individual patients. This review addresses opportunities, challenges, and future directions of high-resolution liquid biopsy proteomics in ophthalmology, with particular emphasis on the large-scale collection of high-quality samples, cutting edge proteomics technology, and artificial intelligence-supported data analysis.


Subject(s)
Ophthalmology , Humans , Proteomics , Artificial Intelligence , Liquid Biopsy , Proteins , Biopsy
SELECTION OF CITATIONS
SEARCH DETAIL
...