1.
J Prosthodont Res ; 65(1): 97-105, 2021 Feb 24.
Article in English | MEDLINE | ID: mdl-32938876

ABSTRACT

PURPOSE: The purpose this study was to investigate the effect of Kern´s air-borne particle abrasion protocol (KAPA) and polishing on two translucent zirconias (4Y, 5Y-zirconias) compared to a traditional zirconia (3Y-zirconia). METHODS: Two different surface treatments were analysed by X-ray diffraction (XRD) and interferometry 1) KAPA (0.1 MPa, 50 µm alumina, 10-12 mm distance, 15 sec and 30 sec and cleaning in ultrasound using isopropyl alcohol 99%) and 2) Clinical-delivery polishing paste (Zircon Brite, Dental Ventures, USA). Shear-bond strength tests (SBS's) were performed with a highly polished and virtually flat surface in combination with a 10-MDP based cement and a surface modified by KAPA in combination with zinc phosphate cement. The SBS was expressed in terms of MPa. RESULTS: The mean values for monoclinic content were 13 wt%, 7 wt% and 2 wt% for 3Y-, 4Y- and 5Y-zirconias respectively, no differences were found between 15 and 30 seconds. Polishing did not result in phase transformation to monoclinic phase in any of the zirconias. The rhombohedral phase was identified in all types of zirconias regardless of surface treatment. Shear-bond strength tests showed 5 MPa for polished/10-MDP based cement and 3 MPa for KAPA/ Zinc phosphate. Statistically significant differences were found between the two different surface treatments but not between the types of zirconias. CONCLUSIONS: KAPA for 15 sec seems to be equal to 30 sec regarding morphology and phase transformation. Sole micro-retention appears not to be fully responsible for the bonding phenomena of 10-MDP and zirconia that underwent KAPA.


Subject(s)
Dental Bonding , Aluminum Oxide , Ceramics , Dental Stress Analysis , Materials Testing , Methacrylates , Resin Cements , Shear Strength , Surface Properties , Zirconium
2.
Clin Exp Dent Res ; 5(4): 427-437, 2019 08.
Article in English | MEDLINE | ID: mdl-31452954

ABSTRACT

Objective: Polyetheretherketone (PEEK) is a polymer used in devices in orthopedic and dental rehabilitation. The aim of this in vitro study was to compare biofilm formation by a range of important oral bacterial species on PEEK, blasted PEEK, commercially pure titanium (cp-Ti), and titanium-6 aluminium-4 vanadium (Ti6Al4V). Material and methods: Coin-shaped samples were manufactured, and the surfaces were characterized using optical interferometry, scanning electron microscopy, energy-dispersive X-ray spectroscopy, and contact angle measurements. Bacterial species of Streptococcus sanguinis, Streptococcus oralis, Enterococcus faecalis, and Streptococcus gordonii were cultured on the four material surfaces for varying amounts of time. Biofilms were quantified following staining with crystal violet. Results: Roughness and contact angle results showed blasted PEEK > PEEK > cp-Ti = Ti6Al4V. There was increased biofilm formation on blasted PEEK by S. sanguinis, S. oralis, and S. gordonii, whereas the bacterial adhesion was similar on PEEK, cp-Ti, and Ti6Al4V. The bacterial growth of E. faecalis was significantly higher on cp-Ti compared with the other three groups. Conclusion: The results, taking into consideration the biofilm formation, suggest that PEEK should perform as well as cp-Ti or TiAl6V4 when used as a dental restorative material.


Subject(s)
Biofilms/growth & development , Dental Abutments/microbiology , Ketones/chemistry , Polyethylene Glycols/chemistry , Prosthodontics/instrumentation , Titanium/chemistry , Bacterial Adhesion , Benzophenones , Enterococcus faecalis/isolation & purification , Materials Testing , Microscopy, Electron, Scanning , Polymers , Streptococcus gordonii/isolation & purification , Streptococcus oralis/isolation & purification , Streptococcus sanguis/isolation & purification , Surface Properties
3.
J Adhes Dent ; 21(2): 107-116, 2019.
Article in English | MEDLINE | ID: mdl-30949624

ABSTRACT

PURPOSE: To investigate direct bonding of a 10-MDP-based cement to two novel translucent yttria-stabilized tetragonal zirconia polycrystal ceramics (4Y-TZP, 5Y-TZP) and observe the influence of thermocycling on this bonding. MATERIALS AND METHODS: Powders of presintered and isostatically pressed 5Y-TZP, 4Y-TZP and 3Y-TZP were mixed with a 10-MDP-based cement (Panavia F 2.0), then stored in deionized water for 48 h at 37°C or thermocycled 10,000 times. Raman spectroscopy and Fourier-transform infrared spectroscopy were used to assess the presence of a functional group (PO32-) that could indicate bonding before and after thermocycling. X-ray photoelectron spectroscopy was used to identify the presence of the suspected Zr-O-P bond in the same specimens. A shear-bond strength (SBS) test was conducted based on ISO 29022:2013. RESULTS: Marked peaks assigned to the asymmetric vibrations of the PO32- functional group were observed in both zirconias before and after thermocycling. The binding energy corresponding to Zr-O-P interactions (531.5 eV) was masked by the aluminosilicate in the filler of the cement. Shear bond strengths were approximately 20 MPa after water storage and approximately 6 MPa after thermocycling. No differences were found between the control group and the translucent zirconias. CONCLUSION: Direct bonding of the 10-MDP-based cement to both 4Y-TZP and 5Y-TZP was highly plausible. Both 4Y-TZP and 5Y-TZP may be promising alternatives to glass-ceramic restorations.


Subject(s)
Dental Bonding , Materials Testing , Shear Strength , Surface Properties , Yttrium , Zirconium
4.
J Biomater Appl ; 33(2): 245-258, 2018 08.
Article in English | MEDLINE | ID: mdl-30001662

ABSTRACT

Objective To investigate the cytokine expression profiles of blood cells exposed to polyetheretherketone and titanium-6 aluminum-4 vanadium materials in vitro. Materials and methods Coin-shaped samples composed of titanium-6 aluminum-4 vanadium, polyetheretherketone, and blasted polyetheretherketone were manufactured. The surfaces of the coins were characterized using optical interferometry, scanning electron microscopy, and contact angle measurements. Peripheral blood mononuclear cells collected from 10 blood donors were cultured for one, three, and six days in the presence or absence of the coins, and then assayed for cytokine production. Quantification of the peripheral blood mononuclear cells attached to the coins was performed using confocal microscopy after immunofluorescence staining. Results The machined titanium-6 aluminum-4 vanadium coins had a smoother surface topography compared to the machined polyetheretherketone and blasted polyetheretherketone. The highest mean contact angle was noted for the blasted polyetheretherketone, followed by the machined polyetheretherketone and titanium-6 aluminum-4 vanadium. The peripheral blood mononuclear cells produced significantly more proinflammatory cytokines when exposed to the polyetheretherketone surface compared to the titanium-6 aluminum-4 vanadium surface, while the blasted polyetheretherketone induced the highest level of proinflammatory cytokine release from the peripheral blood mononuclear cells. Significantly more cells attached to both polyetheretherketone surfaces, as compared to the titanium-6 aluminum-4 vanadium surface. Conclusion Polyetheretherketone induces a stronger inflammatory response from peripheral blood mononuclear cells than does titanium-6 aluminum-4 vanadium. Surface topography has an impact on cytokine release from peripheral blood mononuclear cells.


Subject(s)
Biocompatible Materials/adverse effects , Cytokines/immunology , Inflammation/etiology , Ketones/adverse effects , Leukocytes, Mononuclear/drug effects , Polyethylene Glycols/adverse effects , Titanium/adverse effects , Alloys , Benzophenones , Humans , Inflammation/immunology , Leukocytes, Mononuclear/immunology , Polymers
5.
Int J Prosthodont ; 31(1): 67­70, 2018.
Article in English | MEDLINE | ID: mdl-29166416

ABSTRACT

PURPOSE: The literature shows that the performance of densely sintered zirconia single crowns seems to be unaffected by the cement material. The purpose of this study was to evaluate the effects of various cement materials on the stress distribution in a monolithic translucent zirconia crown. MATERIALS AND METHODS: A crown-cement-dentin complex was modeled. Six cements were evaluated: zinc phosphate, glass-ionomer, resin-modified glass-ionomer, dual-cure resin, calcium aluminate-based, and a theoretical or conceptual cement with mechanical properties close to those of dentin (ie, monoblock cement). RESULTS: While varying stress concentrations were found within the cements, the stress concentrations in the crown and dentin were consistent irrespective of cement material. CONCLUSION: Within the limitations of this study, it can be concluded that cement material had a negligible effect on stress distribution in the monolithic zirconia crown.


Subject(s)
Crowns , Dental Cements/chemistry , Dental Materials/chemistry , Zirconium/chemistry , Dental Prosthesis Design , Dental Stress Analysis , Elastic Modulus , Finite Element Analysis , Imaging, Three-Dimensional , Materials Testing , Surface Properties