Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Proc (Bayl Univ Med Cent) ; 30(1): 57-58, 2017 Jan.
Article in English | MEDLINE | ID: mdl-28127134

ABSTRACT

Syncope can result from certain activities that trigger an exaggerated physiological response in susceptible individuals; examples include cough, laugh, and micturition syncope. We report a novel cause for syncope, that due to reflex bradycardia and asystole produced by the use of asthma inhalers. We discuss the possible mechanisms for this effect and briefly review other breathing-related causes of bradycardia.

2.
Proc (Bayl Univ Med Cent) ; 27(3): 226-8, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24982569

ABSTRACT

Firefighters who have received an implantable cardioverter-defibrillator (ICD) are asked to retire or are permanently placed on restricted duty because of concerns about their being incapacitated by an ICD shock during a fire emergency. We present the case of a 40-year-old firefighter who, after surviving sudden cardiac arrest and undergoing ICD implantation, sought to demonstrate his fitness for active duty by completing a high-intensity, occupation-specific cardiac rehabilitation training program. The report details the exercise training, ICD monitoring, and stress testing that he underwent. During the post-training treadmill stress test in firefighter turnout gear, the patient reached a functional capacity of 17 metabolic equivalents (METs), exceeding the 12-MET level required for his occupation. He had no ICD shock therapy or recurrent sustained arrhythmias during stress testing or at any time during his cardiac rehabilitation stay. By presenting this case, we hope to stimulate further discussion about firefighters who have an ICD, can meet the functional capacity requirements of their occupation, and want to return to work.

3.
Circ Heart Fail ; 3(6): 650-8, 2010 Nov.
Article in English | MEDLINE | ID: mdl-20852059

ABSTRACT

BACKGROUND: Left ventricular (LV) remodeling has been attributed to the segmental loss of viable myocardium due to myocardial infarction (MI), which results in redistribution of cardiac workload, with increased regional wall stress in and around the infarct zone. Because ventricular pacing has been shown to reduce regional wall stress and workload in regions near the pacing site, this trial was designed to test whether chronic pacing near the infarct attenuates LV remodeling. METHODS AND RESULTS: Eighty patients with an anterior MI, peak creatine kinase >2000 mU/mL, ejection fraction ≤35%, wall motion abnormality (WMA) in >5 of 16 segments, and QRS <120 ms, were randomized to either control (implantable cardioverter-defibrillator [ICD]) or biventricular pacing with peri-infarct LV lead placement (cardiac resynchronization therapy [CRT]-D) arms between 2 and 14 days after the MI. The primary end point-change in LV end-diastolic volume (LVEDV) from baseline to 12 months-was not significantly different between the 2 groups (CRT, 10.6±27.7 mL; ICD, 11.2±31.2 mL; 2-sample t test P>0.05). In a hypothesis-generating secondary analysis, there was a sustained reduction in the WMA score at 12 months in paced patients (CRT, -0.16±0.28; ICD, -0.01±0.24, 2-sample t test P=0.03). No differences were found in the therapy-related event rate, hospitalizations, or mortality (all P>0.05). CONCLUSIONS: Chronic pacing in the infarct region did not alter the primary end point of LV remodeling over 1 year.


Subject(s)
Anterior Wall Myocardial Infarction/complications , Anterior Wall Myocardial Infarction/therapy , Cardiac Resynchronization Therapy , Cardiomegaly/prevention & control , Dilatation, Pathologic/prevention & control , Adult , Aged , Aged, 80 and over , Anterior Wall Myocardial Infarction/physiopathology , Cardiomegaly/etiology , Defibrillators, Implantable , Dilatation, Pathologic/etiology , Feasibility Studies , Female , Humans , Male , Middle Aged , Single-Blind Method , Treatment Outcome , Ventricular Remodeling
4.
Am J Cardiol ; 96(3): 414-6, 2005 Aug 01.
Article in English | MEDLINE | ID: mdl-16054471

ABSTRACT

We performed a retrospective analysis of 250 records of consecutive, newly implanted, pacemaker patients from a single center to determine the rate of postimplant complications and observations discovered before and during the prehospital discharge evaluation. No observations occurred in 246 of 250 patients (98.4%) (1-sided 95% confidence interval 96.4%). Of the 250 patients, 4 had observations that were discovered at the prehospital discharge check and required reprogramming to increase the sensitivity safety margin (3 atrial and 1 ventricular). We documented only 1 complication that was discovered before the predischarge evaluation through telemetry and resulted in an atrial lead revision.


Subject(s)
Pacemaker, Artificial , Patient Discharge , Postoperative Complications/diagnosis , Equipment Failure , Humans , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...