J Ultrasound Med ; 40(7): 1451-1458, 2021 Jul.
Article in English | MEDLINE | ID: mdl-32951219

ABSTRACT

We report 166 microinvasive ultrasound-guided carpal tunnel releases using the MICROi-Blade (Summit Medical Products, Inc, Sandy, UT), a needle-based tool for cutting under ultrasound guidance. The 6-month follow-up of the first 21 cases, including 5 bilateral releases, showed a progressive reduction in median pain scores, Boston Carpal Tunnel Questionnaire (BCTQ) Symptom Severity Scale scores, and BCTQ Functional Status Scale scores. The median return to work was 7 days. The 3-month follow-up of 62 subsequent cases showed similar improvement in the BCTQ scores and return to work. There were no complications. This report supports the effectiveness of the technique.


Subject(s)
Carpal Tunnel Syndrome , Boston , Carpal Tunnel Syndrome/diagnostic imaging , Carpal Tunnel Syndrome/surgery , Humans , Surveys and Questionnaires , Ultrasonography , Wrist