1.
Sci Rep ; 14(1): 14161, 2024 06 19.
Article in English | MEDLINE | ID: mdl-38898086

ABSTRACT

Ultrasound (US) has gained popularity as a guidance modality for percutaneous needle insertions because it is widely available and non-ionizing. However, coordinating scanning and needle insertion still requires significant experience. Current assistance solutions utilize optical or electromagnetic tracking (EMT) technology directly integrated into the US device or probe. This results in specialized devices or introduces additional hardware, limiting the ergonomics of both the scanning and insertion process. We developed the first ultrasound (US) navigation solution designed to be used as a non-permanent accessory for existing US devices while maintaining the ergonomics during the scanning process. A miniaturized EMT source is reversibly attached to the US probe, temporarily creating a combined modality that provides real-time anatomical imaging and instrument tracking at the same time. Studies performed with 11 clinical operators show that the proposed navigation solution can guide needle insertions with a targeting accuracy of about 5 mm, which is comparable to existing approaches and unaffected by repeated attachment and detachment of the miniaturized tracking solution. The assistance proved particularly helpful for non-expert users and needle insertions performed outside of the US plane. The small size and reversible attachability of the proposed navigation solution promises streamlined integration into the clinical workflow and widespread access to US navigated punctures.


Subject(s)
Electromagnetic Phenomena , Needles , Humans , Ultrasonography, Interventional/methods , Ultrasonography, Interventional/instrumentation , Miniaturization , Equipment Design , Phantoms, Imaging
2.
Sci Rep ; 14(1): 10055, 2024 05 02.
Article in English | MEDLINE | ID: mdl-38698058

ABSTRACT

Endoscopic transgastric necrosectomy is crucial in the management of complications resulting from necrotizing pancreatitis. However, both real-time and visual-spatial information is lacking during the procedure, thereby jeopardizing a precise positioning of the endoscope. We conducted a proof-of-concept study with the aim of overcoming these technical difficulties. For this purpose, a three-dimensional (3D) phantom of a stomach and pancreatic necroses was 3D-printed based on spatial information from individual patient CT scans and subsequently integrated into a silicone torso. An electromagnetic (EM) sensor was adjusted inside the endoscope´s working channel. A software interface enabled real time visualization. The accuracy of this novel assistant system was tested ex vivo by four experienced interventional endoscopists who were supposed to reach seven targets inside the phantom in six different experimental runs of simulated endoscopic transgastric necrosectomy. Supported by endoscopic camera view combined with real-time 3D visualization, all endoscopists reached the targets with a targeting error ranging between 2.6 and 6.5 mm in a maximum of eight minutes. In summary, the EM tracking system might increase efficacy and safety of endoscopic transgastric necrosectomy at the experimental level by enhancing visualization. Yet, a broader feasibility study and further technical improvements are mandatory before aiming at implementation into clinical setting.


Subject(s)
Electromagnetic Phenomena , Humans , Phantoms, Imaging , Stomach/surgery , Stomach/diagnostic imaging , Pancreatitis, Acute Necrotizing/surgery , Pancreatitis, Acute Necrotizing/diagnostic imaging , Endoscopy/methods , Pancreas/surgery , Printing, Three-Dimensional , Surgical Navigation Systems , Imaging, Three-Dimensional/methods
3.
Int J Comput Assist Radiol Surg ; 12(6): 1059-1067, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28357627

ABSTRACT

PURPOSE: Electromagnetic tracking is the gold standard for instrument tracking and navigation in the clinical setting without line of sight. Whilst clinical platforms exist for interventional bronchoscopy and neurosurgical navigation, the limited flexibility and high costs of electromagnetic tracking (EMT) systems for research investigations mitigate against a better understanding of the technology's characterisation and limitations. The Anser project provides an open-source implementation for EMT with particular application to image-guided interventions. METHODS: This work provides implementation schematics for our previously reported EMT system which relies on low-cost acquisition and demodulation techniques using both National Instruments and Arduino hardware alongside MATLAB support code. The system performance is objectively compared to other commercial tracking platforms using the Hummel assessment protocol. RESULTS: Positional accuracy of 1.14 mm and angular rotation accuracy of [Formula: see text] are reported. Like other EMT platforms, Anser is susceptible to tracking errors due to eddy current and ferromagnetic distortion. The system is compatible with commercially available EMT sensors as well as the Open Network Interface for image-guided therapy (OpenIGTLink) for easy communication with visualisation and medical imaging toolkits such as MITK and 3D Slicer. CONCLUSIONS: By providing an open-source platform for research investigations, we believe that novel and collaborative approaches can overcome the limitations of current EMT technology.


Subject(s)
Electromagnetic Phenomena , Surgery, Computer-Assisted/methods , Humans
4.
Int J Comput Assist Radiol Surg ; 12(6): 931-940, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28332158

ABSTRACT

PURPOSE: Percutaneous radiofrequency ablation (RFA) of thyroid nodules is an alternative to surgical resection that offers the benefits of minimal scars for the patient, lower complication rates, and shorter treatment times. Ultrasound (US) is the preferred modality for guiding these procedures. The needle is usually kept within the US scanning plane to ensure needle visibility. However, this restricts flexibility in both transducer and needle movement and renders the procedure difficult, especially for inexperienced users. Existing navigation solutions often involve electromagnetic (EM) tracking, which requires placement of an external field generator (FG) in close proximity of the intervention site in order to avoid distortion of the EM field. This complicates the clinical workflow as placing the FG while ensuring that it neither restricts the physician's workspace nor affects tracking accuracy is awkward and time-consuming. METHODS: The EchoTrack concept overcomes these issues by combining the US probe and the EM FG in one modality, simultaneously providing both real-time US and tracking data without requiring the placement of an external FG for tracking. We propose a system and workflow to use EchoTrack for RFA of thyroid nodules. RESULTS: According to our results, the overall error of the EchoTrack system resulting from errors related to tracking and calibration is below 2 mm. Navigated thyroid RFA with the proposed concept is clinically feasible. Motion of internal critical structures relative to external markers can be up to several millimeters in extreme cases. CONCLUSIONS: The EchoTrack concept with its simple setup, flexibility, improved needle visualization, and additional guidance information has high potential to be clinically used for thyroid RFA.


Subject(s)
Catheter Ablation/methods , Surgery, Computer-Assisted/methods , Thyroid Gland/surgery , Thyroid Nodule/surgery , Ultrasonography/methods , Humans , Motion