Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Electrophoresis ; 33(9-10): 1411-20, 2012 May.
Article in English | MEDLINE | ID: mdl-22648809

ABSTRACT

Resolution of DNA fragments separated by electrophoresis in polymer solutions ("matrices") is determined by both the spacing between peaks and the width of the peaks. Prior research on the development of high-performance separation matrices has been focused primarily on optimizing DNA mobility and matrix selectivity, and gave less attention to peak broadening. Quantitative data are rare for peak broadening in systems in which high electric field strengths are used (>150 V/cm), which is surprising since capillary and microchip-based systems commonly run at these field strengths. Here, we report results for a study of band broadening behavior for ssDNA fragments on a glass microfluidic chip, for electric field strengths up to 320 V/cm. We compare dispersion coefficients obtained in a poly(N,N-dimethylacrylamide) (pDMA) separation matrix that was developed for chip-based DNA sequencing with a commercially available linear polyacrylamide (LPA) matrix commonly used in capillaries. Much larger DNA dispersion coefficients were measured in the LPA matrix as compared to the pDMA matrix, and the dependence of dispersion coefficient on DNA size and electric field strength were found to differ quite starkly in the two matrices. These observations lead us to propose that DNA migration mechanisms differ substantially in our custom pDMA matrix compared to the commercially available LPA matrix. We discuss the implications of these results in terms of developing optimal matrices for specific separation (microchip or capillary) platforms.


Subject(s)
Acrylamides/chemistry , Acrylic Resins/chemistry , DNA, Single-Stranded/analysis , Electrophoresis, Microchip/instrumentation , DNA, Single-Stranded/chemistry , Electrophoresis, Microchip/methods
2.
Electrophoresis ; 30(12): 2014-24, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19582705

ABSTRACT

In 2009, electrophoretically driven DNA separations in slab gels and capillaries have the sepia tones of an old-fashioned technology in the eyes of many, even while they remain ubiquitously used, fill a unique niche, and arguably have yet to reach their full potential. For comic relief, what is old becomes new again: agarose slab gel separations are used to prepare DNA samples for "next-gen" sequencing platforms (e.g. the Illumina and 454 machines) - dsDNA molecules within a certain size range are "cut out" of a gel and recovered for subsequent "massively parallel" pyrosequencing. In this review, we give a Barron lab perspective on how our comprehension of DNA migration mechanisms in electrophoresis has evolved, since the first reports of DNA separations by CE ( approximately 1989) until now, 20 years later. Fused-silica capillaries and borosilicate glass and plastic microchips quietly offer increasing capacities for fast (and even "ultra-fast"), efficient DNA separations. While the channel-by-channel scaling of both old and new electrophoresis platforms provides key flexibility, it requires each unique DNA sample to be prepared in its own micro or nanovolume. This Achilles' heel of electrophoresis technologies left an opening through which pooled sample, next-gen DNA sequencing technologies rushed. We shall see, over time, whether sharpening understanding of transitions in DNA migration modes in crosslinked gels, nanogel solutions, and uncrosslinked polymer solutions will allow electrophoretic DNA analysis technologies to flower again. Microchannel electrophoresis, after a quiet period of metamorphosis, may emerge sleeker and more powerful, to claim its own important niche applications.


Subject(s)
DNA/chemistry , Electrophoresis, Capillary/methods , Electrophoresis, Microchip/methods , Acrylamides/chemistry , Acrylic Resins/chemistry , Chemical Phenomena , DNA, Single-Stranded/isolation & purification , Hydrophobic and Hydrophilic Interactions , Stochastic Processes , Viscosity
3.
Electrophoresis ; 29(23): 4669-76, 2008 Dec.
Article in English | MEDLINE | ID: mdl-19053064

ABSTRACT

By using a microfluidic electrophoresis platform to perform DNA sequencing, genomic information can be obtained more quickly and affordably than the currently employed capillary array electrophoresis instruments. Previous research in our group has shown that physically cross-linked, hydrophobically modified polyacrylamide matrices separate dsDNA more effectively than linear polyacrylamide (LPA) solutions. Expanding upon this work, we have synthesized a series of LPA-co-dihexylacrylamide block copolymers specifically designed to electrophoretically sequence ssDNA quickly and efficiently on a microfluidic device. By incorporating very small amounts of N,N-dihexylacrylamide, a hydrophobic monomer, these copolymer solutions achieved up to approximately 10% increases in average DNA sequencing read length over LPA homopolymer solutions of matched molar mass. Additionally, the inclusion of the small amount of hydrophobe does not significantly increase the polymer solution viscosities, relative to LPA solutions, so that channel loading times between the copolymers and the homopolymers are similar. The resulting polymer solutions are capable of providing enhanced sequencing separations in a short period of time without compromising the ability to rapidly load and unload the matrix from a microfluidic device.


Subject(s)
Electrophoresis, Microchip/methods , Sequence Analysis, DNA/methods , Acrylic Resins/chemical synthesis , Acrylic Resins/chemistry , DNA, Single-Stranded/chemistry , DNA, Single-Stranded/genetics , Humans , Hydrophobic and Hydrophilic Interactions , Microscopy, Fluorescence , Rheology , Viscosity
4.
Electrophoresis ; 29(23): 4618-26, 2008 Dec.
Article in English | MEDLINE | ID: mdl-19053153

ABSTRACT

The reference human genome provides an adequate basis for biological researchers to study the relationship between genotype and the associated phenotypes, but a large push is underway to sequence many more genomes to determine the role of various specificities among different individuals that control these relationships and to enable the use of human genome data for personalized and preventative healthcare. The current electrophoretic methodology for sequencing an entire mammalian genome, which includes standard molecular biology techniques for genomic sample preparation and the separation of DNA fragments using capillary array electrophoresis, remains far too expensive ($5 million) to make genome sequencing ubiquitous. The National Human Genome Research Institute has put forth goals to reduce the cost of human genome sequencing to $100,000 in the short term and $1000 in the long term to spur the innovative development of technologies that will permit the routine sequencing of human genomes for use as a diagnostic tool for disease. Since the announcement of these goals, several companies have developed and released new, non-electrophoresis-based sequencing instruments that enable massive throughput in the gathering of genomic information. In this review, we discuss the advantages and limitations of these new, massively parallel sequencers and compare them with the currently developing next generation of electrophoresis-based genetic analysis platforms, specifically microchip electrophoresis devices, in the context of three distinct types of genetic analysis.


Subject(s)
Electrophoresis, Capillary/methods , Sequence Analysis, DNA/methods , Electrophoresis, Capillary/economics , Electrophoresis, Capillary/instrumentation , Electrophoresis, Microchip , Fluorescent Dyes , Histocompatibility Testing , Human Genome Project , Humans , Minisatellite Repeats , National Institutes of Health (U.S.) , Nucleic Acid Hybridization , Sequence Analysis, DNA/economics , Sequence Analysis, DNA/instrumentation , United States
5.
Electrophoresis ; 29(23): 4652-62, 2008 Dec.
Article in English | MEDLINE | ID: mdl-19053156

ABSTRACT

Electrophoresis-based DNA sequencing is the only proven technology for the de novo sequencing of large and complex genomes. Miniaturization of capillary array electrophoresis (CAE) instruments can increase sequencing throughput and decrease cost while maintaining the high quality and long read lengths that has made CAE so successful for de novo sequencing. The limited availability of high-performance polymer matrices and wall coatings designed specifically for microchip-sequencing platforms continues to be a major barrier to the successful development of a commercial microchip-sequencing instrument. It has been generally assumed that the matrices and wall coatings that have been developed for use in commercial CAE instruments will be able to be implemented directly into microchip devices with little to no change in sequencing performance. Here, we show that sequencing matrices developed specifically for microchip electrophoresis systems can deliver read lengths that are 150-300 bases longer on chip than some of the most widely used polymer-sequencing matrices available commercially. Additionally, we show that the coating ability of commercial matrices is much less effective in the borosilicate chips used in this study. These results lead to the conclusion that new materials must be developed to make high-performance microfabricated DNA-sequencing instruments a reality.


Subject(s)
Electrophoresis, Microchip/methods , Sequence Analysis, DNA/methods , Acrylamides/chemistry , Acrylic Resins/chemistry , DNA/chemistry , DNA/genetics , Humans , Molecular Weight , Polymers/chemical synthesis , Polymers/chemistry , Rheology , Viscosity
6.
Electrophoresis ; 29(23): 4663-8, 2008 Dec.
Article in English | MEDLINE | ID: mdl-19053157

ABSTRACT

Previous studies have reported that mixed molar mass polymer matrices show enhanced DNA sequencing fragment separation compared with matrices formulated from a single average molar mass. Here, we describe a systematic study to investigate the effects of varying the amounts of two different average molar mass polymers on the DNA sequencing ability of poly(N,N-dimethylacrylamide) (pDMA) sequencing matrices in microfluidic chips. Two polydisperse samples of pDMA, with weight-average molar masses of 3.5 MDa and 770 kDa, were mixed at various fractional concentrations while maintaining the overall polymer concentration at 5% w/v. We show that although the separation of short DNA fragments depends strongly on the overall solution concentration of the polymer, inclusion of the high-molar mass polymer is essential to achieve read lengths of interest (>400 bases) for many sequencing applications. Our results also show that one of the blended matrices, comprised of 3% 3.5 MDa pDMA and 2% 770 kDa pDMA, yields similar sequencing read lengths (>520 bases on average) to the high-molar mass matrix alone, while also providing a fivefold reduction in zero-shear viscosity. These results indicate that the long read lengths achieved in a viscous, high-molar mass polymer matrix are also possible to achieve in a tuned, blended matrix of high- and low-molar mass polymers with a much lower overall solution viscosity.


Subject(s)
Electrophoresis, Microchip/methods , Sequence Analysis, DNA/methods , Acrylamides/chemistry , DNA/chemistry , DNA/genetics , Humans , Microfluidics , Molecular Weight , Viscosity
7.
Proc Natl Acad Sci U S A ; 105(2): 476-81, 2008 Jan 15.
Article in English | MEDLINE | ID: mdl-18184818

ABSTRACT

To realize the immense potential of large-scale genomic sequencing after the completion of the second human genome (Venter's), the costs for the complete sequencing of additional genomes must be dramatically reduced. Among the technologies being developed to reduce sequencing costs, microchip electrophoresis is the only new technology ready to produce the long reads most suitable for the de novo sequencing and assembly of large and complex genomes. Compared with the current paradigm of capillary electrophoresis, microchip systems promise to reduce sequencing costs dramatically by increasing throughput, reducing reagent consumption, and integrating the many steps of the sequencing pipeline onto a single platform. Although capillary-based systems require approximately 70 min to deliver approximately 650 bases of contiguous sequence, we report sequencing up to 600 bases in just 6.5 min by microchip electrophoresis with a unique polymer matrix/adsorbed polymer wall coating combination. This represents a two-thirds reduction in sequencing time over any previously published chip sequencing result, with comparable read length and sequence quality. We hypothesize that these ultrafast long reads on chips can be achieved because the combined polymer system engenders a recently discovered "hybrid" mechanism of DNA electromigration, in which DNA molecules alternate rapidly between repeating through the intact polymer network and disrupting network entanglements to drag polymers through the solution, similar to dsDNA dynamics we observe in single-molecule DNA imaging studies. Most importantly, these results reveal the surprisingly powerful ability of microchip electrophoresis to provide ultrafast Sanger sequencing, which will translate to increased system throughput and reduced costs.


Subject(s)
Electrophoresis, Microchip/instrumentation , Electrophoresis, Microchip/methods , Oligonucleotide Array Sequence Analysis/methods , Sequence Analysis, DNA/instrumentation , Sequence Analysis, DNA/methods , DNA/analysis , DNA, Single-Stranded/chemistry , Equipment Design , Genome, Human , Humans , Microscopy, Video/methods , Polymers/chemistry , Reproducibility of Results , Time Factors
8.
Electrophoresis ; 27(19): 3689-702, 2006 Oct.
Article in English | MEDLINE | ID: mdl-17031784

ABSTRACT

Although a finished human genome reference sequence is now available, the ability to sequence large, complex genomes remains critically important for researchers in the biological sciences, and in particular, continued human genomic sequence determination will ultimately help to realize the promise of medical care tailored to an individual's unique genetic identity. Many new technologies are being developed to decrease the costs and to dramatically increase the data acquisition rate of such sequencing projects. These new sequencing approaches include Sanger reaction-based technologies that have electrophoresis as the final separation step as well as those that use completely novel, nonelectrophoretic methods to generate sequence data. In this review, we discuss the various advances in sequencing technologies and evaluate the current limitations of novel methods that currently preclude their complete acceptance in large-scale sequencing projects. Our primary goal is to analyze and predict the continuing role of electrophoresis in large-scale DNA sequencing, both in the near and longer term.


Subject(s)
Electrophoresis/trends , Genome, Human , Genomics/trends , Sequence Analysis, DNA/trends , Animals , Electrophoresis/methods , Humans
9.
Electrophoresis ; 25(21-22): 3564-88, 2004 Nov.
Article in English | MEDLINE | ID: mdl-15565709

ABSTRACT

Advances in microchannel electrophoretic separation systems for DNA analyses have had important impacts on biological and biomedical sciences, as exemplified by the successes of the Human Genome Project (HGP). As we enter a new era in genomic science, further technological innovations promise to provide other far-reaching benefits, many of which will require continual increases in sequencing and genotyping efficiency and throughput, as well as major decreases in the cost per analysis. Since the high-resolution size- and/or conformation-based electrophoretic separation of DNA is the most critical step in many genetic analyses, continual advances in the development of materials and methods for microchannel electrophoretic separations will be needed to meet the massive demand for high-quality, low-cost genomic data. In particular, the development (and commercialization) of miniaturized genotyping platforms is needed to support and enable the future breakthroughs of biomedical science. In this review, we briefly discuss the major sequencing and genotyping techniques in which high-throughput and high-resolution electrophoretic separations of DNA play a significant role. We review recent advances in the development of technology for capillary electrophoresis (CE), including capillary array electrophoresis (CAE) systems. Most of these CE/CAE innovations are equally applicable to implementation on microfabricated electrophoresis chips. Major effort is devoted to discussing various key elements needed for the development of integrated and practical microfluidic sequencing and genotyping platforms, including chip substrate selection, microchannel design and fabrication, microchannel surface modification, sample preparation, analyte detection, DNA sieving matrices, and device integration. Finally, we identify some of the remaining challenges, and some of the possible routes to further advances in high-throughput DNA sequencing and genotyping technologies.


Subject(s)
Electrophoresis, Microchip/methods , Sequence Analysis, DNA/methods , Animals , DNA Mutational Analysis/instrumentation , DNA Mutational Analysis/methods , Electrophoresis, Microchip/instrumentation , Equipment Design , Genotype , Humans , Polymers
SELECTION OF CITATIONS
SEARCH DETAIL
...