Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 30
Filter
Add more filters










Publication year range
1.
Nat Methods ; 21(6): 1044-1052, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38720062

ABSTRACT

The spatial distribution of cell surface proteins governs vital processes of the immune system such as intercellular communication and mobility. However, fluorescence microscopy has limited scalability in the multiplexing and throughput needed to drive spatial proteomics discoveries at subcellular level. We present Molecular Pixelation (MPX), an optics-free, DNA sequence-based method for spatial proteomics of single cells using antibody-oligonucleotide conjugates (AOCs) and DNA-based, nanometer-sized molecular pixels. The relative locations of AOCs are inferred by sequentially associating them into local neighborhoods using the sequence-unique DNA pixels, forming >1,000 spatially connected zones per cell in 3D. For each single cell, DNA-sequencing reads are computationally arranged into spatial proteomics networks for 76 proteins. By studying immune cell dynamics using spatial statistics on graph representations of the data, we identify known and new patterns of spatial organization of proteins on chemokine-stimulated T cells, highlighting the potential of MPX in defining cell states by the spatial arrangement of proteins.


Subject(s)
Proteomics , Single-Cell Analysis , Proteomics/methods , Single-Cell Analysis/methods , Humans , T-Lymphocytes/metabolism , Sequence Analysis, DNA/methods
2.
Int J Mol Sci ; 20(23)2019 Dec 02.
Article in English | MEDLINE | ID: mdl-31810358

ABSTRACT

The burden of colorectal cancer (CRC) is considerable-approximately 1.8 million people are diagnosed each year with CRC and of these about half will succumb to the disease. In the case of CRC, there is strong evidence that an early diagnosis leads to a better prognosis, with metastatic CRC having a 5-year survival that is only slightly greater than 10% compared with up to 90% for stage I CRC. Clearly, biomarkers for the early detection of CRC would have a major clinical impact. We implemented a coherent gel-based proteomics biomarker discovery platform for the identification of clinically useful biomarkers for the early detection of CRC. Potential protein biomarkers were identified by a 2D gel-based analysis of a cohort composed of 128 CRC and site-matched normal tissue biopsies. Potential biomarkers were prioritized and assays to quantitatively measure plasma expression of the candidate biomarkers were developed. Those biomarkers that fulfilled the preset criteria for technical validity were validated in a case-control set of plasma samples, including 70 patients with CRC, adenomas, or non-cancer diseases and healthy individuals in each group. We identified 63 consistently upregulated polypeptides (factor of four-fold or more) in our proteomics analysis. We selected 10 out of these 63 upregulated polypeptides, and established assays to measure the concentration of each one of the ten biomarkers in plasma samples. Biomarker levels were analyzed in plasma samples from healthy individuals, individuals with adenomas, CRC patients, and patients with non-cancer diseases and we identified one protein, tropomyosin 3 (Tpm3) that could discriminate CRC at a significant level (p = 0.0146). Our results suggest that at least one of the identified proteins, Tpm3, could be used as a biomarker in the early detection of CRC, and further studies should provide unequivocal evidence for the real-life clinical validity and usefulness of Tpm3.


Subject(s)
Biomarkers, Tumor/blood , Colorectal Neoplasms/blood , Early Detection of Cancer , Proteomics , Adult , Aged , Aged, 80 and over , Colorectal Neoplasms/pathology , Disease-Free Survival , Electrophoresis, Gel, Two-Dimensional , Female , Humans , Male , Middle Aged , Prognosis
3.
Genome Biol ; 17(1): 188, 2016 09 19.
Article in English | MEDLINE | ID: mdl-27640647

ABSTRACT

We present a scalable, integrated strategy for coupled protein and RNA detection from single cells. Our approach leverages the DNA polymerase activity of reverse transcriptase to simultaneously perform proximity extension assays and complementary DNA synthesis in the same reaction. Using the Fluidigm C1™ system, we profile the transcriptomic and proteomic response of a human breast adenocarcinoma cell line to a chemical perturbation, benchmarking against in situ hybridizations and immunofluorescence staining, as well as recombinant proteins, ERCC Spike-Ins, and population lysate dilutions. Through supervised and unsupervised analyses, we demonstrate synergies enabled by simultaneous measurement of single-cell protein and RNA abundances. Collectively, our generalizable approach highlights the potential for molecular metadata to inform highly-multiplexed single-cell analyses.


Subject(s)
Breast Neoplasms/genetics , Proteome/genetics , RNA/genetics , Transcriptome/genetics , Breast Neoplasms/pathology , Female , Gene Expression Profiling , Humans , RNA/biosynthesis , Single-Cell Analysis
4.
Cell Rep ; 14(2): 380-9, 2016 Jan 12.
Article in English | MEDLINE | ID: mdl-26748716

ABSTRACT

Significant advances have been made in methods to analyze genomes and transcriptomes of single cells, but to fully define cell states, proteins must also be accessed as central actors defining a cell's phenotype. Methods currently used to analyze endogenous protein expression in single cells are limited in specificity, throughput, or multiplex capability. Here, we present an approach to simultaneously and specifically interrogate large sets of protein and RNA targets in lysates from individual cells, enabling investigations of cell functions and responses. We applied our method to investigate the effects of BMP4, an experimental therapeutic agent, on early-passage glioblastoma cell cultures. We uncovered significant heterogeneity in responses to treatment at levels of RNA and protein, with a subset of cells reacting in a distinct manner to BMP4. Moreover, we found overall poor correlation between protein and RNA at the level of single cells, with proteins more accurately defining responses to treatment.


Subject(s)
Proteins/genetics , Proteomics/methods , RNA/genetics , Cell Line, Tumor , Humans
5.
N Biotechnol ; 33(3): 311-30, 2016 May 25.
Article in English | MEDLINE | ID: mdl-26514324

ABSTRACT

The REvolutionary Approaches and Devices for Nucleic Acid analysis (READNA) project received funding from the European Commission for 41/2 years. The objectives of the project revolved around technological developments in nucleic acid analysis. The project partners have discovered, created and developed a huge body of insights into nucleic acid analysis, ranging from improvements and implementation of current technologies to the most promising sequencing technologies that constitute a 3(rd) and 4(th) generation of sequencing methods with nanopores and in situ sequencing, respectively.


Subject(s)
Biotechnology/methods , DNA/analysis , DNA/genetics , Animals , Click Chemistry , Exome/genetics , Humans , Mass Spectrometry , Sequence Analysis, DNA
6.
Clin Proteomics ; 12(1): 10, 2015.
Article in English | MEDLINE | ID: mdl-25987887

ABSTRACT

BACKGROUND: Current methods widely deployed for colorectal cancers (CRC) screening lack the necessary sensitivity and specificity required for population-based early disease detection. Cancer-specific protein biomarkers are thought to be produced either by the tumor itself or other tissues in response to the presence of cancers or associated conditions. Equally, known examples of cancer protein biomarkers (e.g., PSA, CA125, CA19-9, CEA, AFP) are frequently found in plasma at very low concentration (pg/mL-ng/mL). New sensitive and specific assays are therefore urgently required to detect the disease at an early stage when prognosis is good following surgical resection. This study was designed to meet the longstanding unmet clinical need for earlier CRC detection by measuring plasma candidate biomarkers of cancer onset and progression in a clinical stage-specific manner. EDTA plasma samples (1 µL) obtained from 75 patients with Dukes' staged CRC or unaffected controls (age and sex matched with stringent inclusion/exclusion criteria) were assayed for expression of 92 human proteins employing the Proseek® Multiplex Oncology I proximity extension assay. An identical set of plasma samples were analyzed utilizing the Bio-Plex Pro™ human cytokine 27-plex immunoassay. RESULTS: Similar quantitative expression patterns for 13 plasma antigens common to both platforms endorsed the potential efficacy of Proseek as an immune-based multiplex assay for proteomic biomarker research. Proseek found that expression of Carcinoembryonic Antigen (CEA), IL-8 and prolactin are significantly correlated with CRC stage. CONCLUSIONS: CEA, IL-8 and prolactin expression were found to identify between control (unaffected), non-malignant (Dukes' A + B) and malignant (Dukes' C + D) stages.

7.
PLoS One ; 9(4): e95192, 2014.
Article in English | MEDLINE | ID: mdl-24755770

ABSTRACT

Medical research is developing an ever greater need for comprehensive high-quality data generation to realize the promises of personalized health care based on molecular biomarkers. The nucleic acid proximity-based methods proximity ligation and proximity extension assays have, with their dual reporters, shown potential to relieve the shortcomings of antibodies and their inherent cross-reactivity in multiplex protein quantification applications. The aim of the present study was to develop a robust 96-plex immunoassay based on the proximity extension assay (PEA) for improved high throughput detection of protein biomarkers. This was enabled by: (1) a modified design leading to a reduced number of pipetting steps compared to the existing PEA protocol, as well as improved intra-assay precision; (2) a new enzymatic system that uses a hyper-thermostabile enzyme, Pwo, for uniting the two probes allowing for room temperature addition of all reagents and improved the sensitivity; (3) introduction of an inter-plate control and a new normalization procedure leading to improved inter-assay precision (reproducibility). The multiplex proximity extension assay was found to perform well in complex samples, such as serum and plasma, and also in xenografted mice and resuspended dried blood spots, consuming only 1 µL sample per test. All-in-all, the development of the current multiplex technique is a step toward robust high throughput protein marker discovery and research.


Subject(s)
Immunoassay/methods , Polymerase Chain Reaction/methods , Animals , Blood Proteins/metabolism , Cross Reactions , DNA-Directed DNA Polymerase/metabolism , Dried Blood Spot Testing , Enzyme Stability , Female , Heterografts , Humans , Mice, Nude , Oligonucleotides/metabolism , Sensitivity and Specificity , Temperature
8.
BMC Cancer ; 13: 598, 2013 Dec 13.
Article in English | MEDLINE | ID: mdl-24330623

ABSTRACT

BACKGROUND: Worldwide more than one million women are annually diagnosed with breast cancer. A considerable fraction of these women receive systemic adjuvant therapy; however, some are cured by primary surgery and radiotherapy alone. Prognostic biomarkers guide stratification of patients into different risk groups and hence improve management of breast cancer patients. Plasma levels of Matrix Metalloproteinase-9 (MMP-9) and its natural inhibitor Tissue inhibitor of metalloproteinase-1 (TIMP-1) have previously been associated with poor patient outcome and resistance to certain forms of chemotherapy. To pursue additional prognostic information from MMP-9 and TIMP-1, the level of the MMP-9 and TIMP-1 complex (MMP-9:TIMP-1) was investigated in plasma from breast cancer patients. METHODS: Detection of protein:protein complexes in plasma was performed using a commercially available ELISA kit and, for the first time, the highly sensitive in-solution proximity ligation assay (PLA). We screened plasma from 465 patients with primary breast cancer for prognostic value of the MMP-9:TIMP-1 complex. Both assays were validated and applied for quantification of MMP-9:TIMP-1 concentration. In this retrospective study, we analyzed the association between the concentration of the MMP-9:TIMP-1 complex and clinicopathological data and disease free survival (DFS) in univariate and multivariate survival analyses. RESULTS: Following successful validation both assays were applied for MMP-9:TIMP-1 measurements. Of the clinicopathological parameters, only menopausal status demonstrated significant association with the MMP-9:TIMP-1 complex; P = 0.03 and P = 0.028 for the ELISA and PLA measurements, respectively. We found no correlation between the MMP-9:TIMP-1 protein complex and DFS neither in univariate nor in multivariate survival analyses. CONCLUSIONS: Despite earlier reports linking MMP-9 and TIMP-1 with prognosis in breast cancer patients, we here demonstrate that plasma levels of the MMP-9:TIMP-1 protein complex hold no prognostic information in primary breast cancer as a stand-alone marker. We demonstrate that the highly sensitive in-solution PLA can be employed for measurements of protein:protein complexes in plasma.


Subject(s)
Biomarkers, Tumor/blood , Breast Neoplasms/blood , Carcinoma, Ductal, Breast/blood , Matrix Metalloproteinase 9/blood , Tissue Inhibitor of Metalloproteinase-1/blood , Aged , Blood Chemical Analysis/standards , Breast Neoplasms/pathology , Carcinoma, Ductal, Breast/pathology , Disease Progression , Disease-Free Survival , Enzyme-Linked Immunosorbent Assay/standards , Female , Humans , Limit of Detection , Middle Aged , Multivariate Analysis , Prognosis , Proportional Hazards Models , Reference Standards , Retrospective Studies
9.
J Transl Med ; 11: 253, 2013 Oct 10.
Article in English | MEDLINE | ID: mdl-24107468

ABSTRACT

BACKGROUND: Although the potential of biomarkers to aid in early detection of colorectal cancer (CRC) is recognized and numerous biomarker candidates have been reported in the literature, to date only few molecular markers have been approved for daily clinical use. METHODS: In order to improve the translation of biomarkers from the bench to clinical practice we initiated a biomarker study focusing on a novel technique, the proximity extension assay, with multiplexing capability and the possible additive effect obtained from biomarker panels. We performed a screening of 74 different biomarkers in plasma derived from a case-control sample set consisting of symptomatic individuals representing CRC patients, patients with adenoma, patients with non-neoplastic large bowel diseases and healthy individuals. RESULTS: After statistical evaluation we found 12 significant indicators of CRC and the receiver operating characteristic (ROC) curve of Carcinoembryonic antigen (CEA), Transferrin Receptor-1 (TFRC), Macrophage migration inhibitory factor (MIF), Osteopontin (OPN/SPP1) and cancer antigen 242 (CA242) showed additive effect. This biomarker panel identified CRC patients with a sensitivity of 56% at 90% specificity and thus the performance is sufficiently high to further investigate this combination of five proteins as serological biomarkers for detection of CRC. Furthermore, when applying the indicators to identify early-stage CRC a combination of CEA, TFRC and CA242 resulted in a ROC curve with an area under the curve of 0.861. CONCLUSIONS: Five plasma protein biomarkers were found to be potential CRC discriminators and three of these were additionally found to be discriminators of early-stage CRC. These explorative data in symptomatic individuals demonstrates the feasibility of the multiplex proximity extension assay for screening of potential serological protein biomarkers and warrants independent analyses in a larger sample cohort, including asymptomatic individuals, to further validate the performances of our CRC biomarker panel.


Subject(s)
Biological Assay/methods , Biomarkers, Tumor/blood , Colorectal Neoplasms/blood , Colorectal Neoplasms/diagnosis , Adult , Aged , Aged, 80 and over , Computer Simulation , Female , Humans , Male , Middle Aged , Multivariate Analysis , ROC Curve , Reference Standards , Reproducibility of Results
10.
PLoS One ; 8(7): e69813, 2013.
Article in English | MEDLINE | ID: mdl-23874999

ABSTRACT

Proximity ligation assay (PLA) has been proven to be a robust protein detection method. The technique is characterized by high sensitivity and specificity, but the assay precision is probably limited by the PCR readout. To investigate this potential limitation and to improve precision, we developed a digital proximity ligation assay for protein measurement in fluids based on amplified single molecule detection. The assay showed significant improvements in precision, and thereby also detection sensitivity, over the conventional real-time PCR readout.


Subject(s)
Biological Assay/methods , Real-Time Polymerase Chain Reaction/methods
11.
PLoS One ; 6(9): e25583, 2011.
Article in English | MEDLINE | ID: mdl-21980495

ABSTRACT

Despite intense interest, methods that provide enhanced sensitivity and specificity in parallel measurements of candidate protein biomarkers in numerous samples have been lacking. We present herein a multiplex proximity ligation assay with readout via realtime PCR or DNA sequencing (ProteinSeq). We demonstrate improved sensitivity over conventional sandwich assays for simultaneous analysis of sets of 35 proteins in 5 µl of blood plasma. Importantly, we observe a minimal tendency to increased background with multiplexing, compared to a sandwich assay, suggesting that higher levels of multiplexing are possible. We used ProteinSeq to analyze proteins in plasma samples from cardiovascular disease (CVD) patient cohorts and matched controls. Three proteins, namely P-selectin, Cystatin-B and Kallikrein-6, were identified as putative diagnostic biomarkers for CVD. The latter two have not been previously reported in the literature and their potential roles must be validated in larger patient cohorts. We conclude that ProteinSeq is promising for screening large numbers of proteins and samples while the technology can provide a much-needed platform for validation of diagnostic markers in biobank samples and in clinical use.


Subject(s)
Immunoassay/methods , Proteomics/methods , Sequence Analysis, DNA/methods , Biomarkers/blood , Blood Proteins/analysis , Blood Proteins/genetics , Humans , Immunoassay/economics , Multivariate Analysis , Proteomics/economics , Sequence Analysis, DNA/economics , Time Factors
12.
Nucleic Acids Res ; 39(15): e102, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21646338

ABSTRACT

Convenient and well-performing protein detection methods for a wide range of targets are in great demand for biomedical research and future diagnostics. Assays without the need for washing steps while still unaffected when analyzing complex biological samples are difficult to develop. Herein, we report a well-characterized nucleic acid proximity-based assay using antibodies, called Proximity Extension Assay (PEA), showing good performance in plasma samples. Target-specific antibody pairs are linked to DNA strands that upon simultaneous binding to the target analyte create a real-time PCR amplicon in a proximity-dependent manner enabled by the action of a DNA polymerase. 3'Exonuclease-capable polymerases were found to be clearly superior in sensitivity over non-3'exonuclease ones. A PEA was set up for IL-8 and GDNF in a user-friendly, homogenous assay displaying femtomolar detection sensitivity, good recovery in human plasma, high specificity and up to 5-log dynamic range in 1 µL samples. Furthermore, we have illustrated the use of a macro-molecular crowding matrix in combination with this homogeneous assay to drive target binding for low-affinity antibodies, thereby improving the sensitivity and increasing affinity reagent availability by lowering assay development dependency on high-affinity antibodies. Assay performance was also confirmed for a multiplex version of PEA.


Subject(s)
Blood Proteins/analysis , Immunoassay/methods , Antibodies , Blood Proteins/immunology , Exonucleases , Humans , Oligonucleotide Probes , Polymerase Chain Reaction , Water/chemistry
13.
Mol Cell Proteomics ; 10(4): M110.004978, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21242282

ABSTRACT

A high throughput protein biomarker discovery tool has been developed based on multiplexed proximity ligation assays in a homogeneous format in the sense of no washing steps. The platform consists of four 24-plex panels profiling 74 putative biomarkers with sub-pm sensitivity each consuming only 1 µl of human plasma sample. The system uses either matched monoclonal antibody pairs or the more readily available single batches of affinity purified polyclonal antibodies to generate the target specific reagents by covalently linking with unique nucleic acid sequences. These paired sequences are united by DNA ligation upon simultaneous target binding forming a PCR amplicon. Multiplex proximity ligation assays thereby converts multiple target analytes into real-time PCR amplicons that are individually quantified using microfluidic high capacity qPCR in nano liter volumes. The assay shows excellent specificity, even in multiplex, by its dual recognition feature, its proximity requirement, and most importantly by using unique sequence specific reporter fragments on both antibody-based probes. To illustrate the potential of this protein detection technology, a pilot biomarker research project was performed using biobanked plasma samples for the detection of colorectal cancer using a multivariate signature.


Subject(s)
Biomarkers, Tumor/blood , Colorectal Neoplasms/diagnosis , Adult , Aged , Aged, 80 and over , Antigens, Tumor-Associated, Carbohydrate/blood , Carcinoembryonic Antigen/blood , Colorectal Neoplasms/blood , Enzyme-Linked Immunosorbent Assay , Female , Humans , Interleukin-8/blood , Male , Middle Aged , Molecular Diagnostic Techniques , Multivariate Analysis , Secretory Leukocyte Peptidase Inhibitor/blood , Statistics, Nonparametric , Tissue Inhibitor of Metalloproteinase-1/blood , Vascular Endothelial Growth Factor A/blood
14.
Clin Chem ; 54(7): 1218-25, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18499900

ABSTRACT

BACKGROUND: Improved methods are required to screen drug candidates for their influences on protein interactions. There is also a compelling need for miniaturization of screening assays, with attendant reductions in reagent consumption and assay costs. METHODS: We used sensitive, miniaturized proximity ligation assays (PLAs) to monitor binding of vascular endothelial growth factor A (VEGF-A) to 2 of its receptors, VEGFR-1 and VEGFR-2. We measured the effects of proteins and low molecular weight compounds capable of disrupting these interactions and compared the results with those obtained by immunoblot analysis. We analyzed 6 different inhibitors: a DNA aptamer, a mixed DNA/RNA aptamer, a monoclonal VEGF-A neutralizing antibody, a monoclonal antibody directed against VEGFR-2, a recombinant competitive protein, and a low molecular weight synthetic molecule. RESULTS: The PLAs were successful for monitoring the formation and inhibition of VEGF-A-receptor complexes, and the results correlated well with those obtained by measuring receptor phosphorylation. The total PLA time is just 3 hours, with minimal manual work and reagent additions. The method allows evaluation of the apparent affinity [half-maximal inhibitory concentration (IC(50))] from a dose-response curve. CONCLUSIONS: The PLA may offer significant advantages over conventional methods for screening the interactions of ligands with their receptors. The assay may prove useful for parallel analyses of large numbers of samples in the screening of inhibitor libraries for promising agents. The technique provides dose-response curves, allowing IC(50) values to be calculated.


Subject(s)
Receptors, Vascular Endothelial Growth Factor/metabolism , Vascular Endothelial Growth Factor A/metabolism , Vascular Endothelial Growth Factor Receptor-2/metabolism , Affinity Labels , Animals , Antibodies, Monoclonal/pharmacology , Aorta/cytology , Aptamers, Nucleotide/chemistry , Aptamers, Nucleotide/pharmacology , Cells, Cultured , Endothelial Cells/drug effects , Endothelial Cells/metabolism , Endothelium, Vascular/cytology , Humans , Ligands , Phosphorylation , Placenta Growth Factor , Pregnancy Proteins/pharmacology , Receptors, Vascular Endothelial Growth Factor/antagonists & inhibitors , Recombinant Proteins/pharmacology , Swine , Vascular Endothelial Growth Factor A/antagonists & inhibitors , Vascular Endothelial Growth Factor A/immunology , Vascular Endothelial Growth Factor Receptor-2/antagonists & inhibitors , Vascular Endothelial Growth Factor Receptor-2/immunology
15.
Clin Chem ; 54(3): 582-9, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18171715

ABSTRACT

BACKGROUND: Sensitive methods are needed for biomarker discovery and validation. We tested one promising technology, multiplex proximity ligation assay (PLA), in a pilot study profiling plasma biomarkers in pancreatic and ovarian cancer. METHODS: We used 4 panels of 6- and 7-plex PLAs to detect biomarkers, with each assay consuming 1 microL plasma and using either matched monoclonal antibody pairs or single batches of polyclonal antibody. Protein analytes were converted to unique DNA amplicons by proximity ligation and subsequently detected by quantitative PCR. We profiled 18 pancreatic cancer cases and 19 controls and 19 ovarian cancer cases and 20 controls for the following proteins: a disintegrin and metalloprotease 8, CA-125, CA 19-9, carboxypeptidase A1, carcinoembryonic antigen, connective tissue growth factor, epidermal growth factor receptor, epithelial cell adhesion molecule, Her2, galectin-1, insulin-like growth factor 2, interleukin-1alpha, interleukin-7, mesothelin, macrophage migration inhibitory factor, osteopontin, secretory leukocyte peptidase inhibitor, tumor necrosis factor alpha, vascular endothelial growth factor, and chitinase 3-like 1. Probes for CA-125 were present in 3 of the multiplex panels. We measured plasma concentrations of the CA-125-mesothelin complex by use of a triple-specific PLA with 2 ligation events among 3 probes. RESULTS: The assays displayed consistent measurements of CA-125 independent of which other markers were simultaneously detected and showed good correlation with Luminex data. In comparison to literature reports, we achieved expected results for other putative markers. CONCLUSION: Multiplex PLA using either matched monoclonal antibodies or single batches of polyclonal antibody should prove useful for identifying and validating sets of putative disease biomarkers and finding multimarker panels.


Subject(s)
Biomarkers, Tumor/blood , Ovarian Neoplasms/diagnosis , Pancreatic Neoplasms/diagnosis , Adult , Aged , Aged, 80 and over , Female , Humans , Immunoassay , Male , Middle Aged , Pilot Projects , Polymerase Chain Reaction/methods , Reproducibility of Results
16.
Proc Natl Acad Sci U S A ; 104(22): 9387-92, 2007 May 29.
Article in English | MEDLINE | ID: mdl-17517648

ABSTRACT

We have developed a procedure for massively parallel resequencing of multiple human genes by combining a highly multiplexed and target-specific amplification process with a high-throughput parallel sequencing technology. The amplification process is based on oligonucleotide constructs, called selectors, that guide the circularization of specific DNA target regions. Subsequently, the circularized target sequences are amplified in multiplex and analyzed by using a highly parallel sequencing-by-synthesis technology. As a proof-of-concept study, we demonstrate parallel resequencing of 10 cancer genes covering 177 exons with average sequence coverage per sample of 93%. Seven cancer cell lines and one normal genomic DNA sample were studied with multiple mutations and polymorphisms identified among the 10 genes. Mutations and polymorphisms in the TP53 gene were confirmed by traditional sequencing.


Subject(s)
Genes, Neoplasm/genetics , Genetic Testing/methods , Mutation/genetics , Neoplasms/genetics , Nucleic Acid Amplification Techniques/methods , Base Sequence , Cell Line, Tumor , Humans , Molecular Sequence Data , Tumor Suppressor Protein p53/genetics
17.
Nat Methods ; 4(4): 327-9, 2007 Apr.
Article in English | MEDLINE | ID: mdl-17369836

ABSTRACT

We present a proximity ligation-based multiplexed protein detection procedure in which several selected proteins can be detected via unique nucleic-acid identifiers and subsequently quantified by real-time PCR. The assay requires a 1-microl sample, has low-femtomolar sensitivity as well as five-log linear range and allows for modular multiplexing without cross-reactivity. The procedure can use a single polyclonal antibody batch for each target protein, simplifying affinity-reagent creation for new biomarker candidates.


Subject(s)
Antibodies/analysis , Biomarkers, Tumor/analysis , Neoplasm Proteins/analysis , Neoplasms/diagnosis , Reverse Transcriptase Polymerase Chain Reaction/methods , Neoplasms/metabolism , Oligonucleotides/analysis , Pilot Projects , Sensitivity and Specificity
18.
Nucleic Acids Res ; 35(7): e47, 2007.
Article in English | MEDLINE | ID: mdl-17317684

ABSTRACT

Herein we present Gene-Collector, a method for multiplex amplification of nucleic acids. The procedure has been employed to successfully amplify the coding sequence of 10 human cancer genes in one assay with uniform abundance of the final products. Amplification is initiated by a multiplex PCR in this case with 170 primer pairs. Each PCR product is then specifically circularized by ligation on a Collector probe capable of juxtapositioning only the perfectly matched cognate primer pairs. Any amplification artifacts typically associated with multiplex PCR derived from the use of many primer pairs such as false amplicons, primer-dimers etc. are not circularized and degraded by exonuclease treatment. Circular DNA molecules are then further enriched by randomly primed rolling circle replication. Amplification was successful for 90% of the targeted amplicons as seen by hybridization to a custom resequencing DNA micro-array. Real-time quantitative PCR revealed that 96% of the amplification products were all within 4-fold of the average abundance. Gene-Collector has utility for numerous applications such as high throughput resequencing, SNP analyses, and pathogen detection.


Subject(s)
Genes, Neoplasm , Polymerase Chain Reaction/methods , DNA Primers , Exons , Genomics/methods , Humans , Oligonucleotide Array Sequence Analysis
19.
Nat Methods ; 3(9): 725-7, 2006 Sep.
Article in English | MEDLINE | ID: mdl-16929318

ABSTRACT

We describe a scheme for biomolecule enumeration by converting nanometer-scale specific molecular recognition events mediated by rolling-circle amplification to fluorescent micrometer-sized DNA molecules amenable to discrete optical detection. Our amplified single-molecule detection (SMD) approach preserves the discrete nature of the molecular population, allowing multiplex detection and highly precise quantification of molecules over a dynamic range of seven orders of magnitude. We apply the method for sensitive detection and quantification of the bacterial pathogen Vibrio cholerae.


Subject(s)
DNA, Bacterial/genetics , DNA, Circular/genetics , Vibrio cholerae/genetics , DNA, Bacterial/chemistry , DNA, Circular/chemistry , Molecular Probe Techniques , Nanotechnology , Sensitivity and Specificity , Spectrometry, Fluorescence/methods
20.
Biol Chem ; 387(6): 769-72, 2006 Jun.
Article in English | MEDLINE | ID: mdl-16800738

ABSTRACT

Prostate-specific antigen (PSA) is a widely used marker for prostate cancer. The utility of PSA tests is limited by their inability to differentiate prostate cancer from non-malignant conditions such as benign prostatic hyperplasia and prostatitis. In circulation, PSA occurs in various complexed and free forms, and specific determination of some of these can be used to improve the diagnostic accuracy of PSA tests. We have previously identified peptides that specifically bind to enzymatically active PSA and using such a peptide we have developed an immunopeptidometric assay for this form of PSA. However, the sensitivity of that assay is too low to measure active PSA at clinically important levels. Recently a novel sensitive immunoassay for analysis of proteins, termed the proximity ligation assay, has been established. Here we describe a sensitive implementation of the proximity ligation assay, which utilizes a PSA-binding peptide and antibody as probes to detect active PSA. The assay has a sensitivity of 0.07 microg/l, which is approximately ten-fold lower than that of our previous assay. It does not cross-react with inactive proPSA or the highly similar kallikrein hK2. Our results show that a highly sensitive immunopeptidometric assay can be developed using proximity ligation. This principle should facilitate establishment of specific assays for active forms of other proteases.


Subject(s)
Immunoassay/methods , Prostate-Specific Antigen/analysis , Prostatic Neoplasms/diagnosis , Antibody Specificity , Biomarkers, Tumor/analysis , Humans , Immunoassay/standards , Male , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...