Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Heart Lung Transplant ; 43(6): 889-900, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38713124

ABSTRACT

BACKGROUND: There is no FDA-approved left ventricular assist device (LVAD) for smaller children permitting routine hospital discharge. Smaller children supported with LVADs typically remain hospitalized for months awaiting heart transplant-a major burden for families and a challenge for hospitals. We describe the initial outcomes of the Jarvik 2015, a miniaturized implantable continuous flow LVAD, in the NHLBI-funded Pumps for Kids, Infants, and Neonates (PumpKIN) study, for bridge-to-heart transplant. METHODS: Children weighing 8 to 30 kg with severe systolic heart failure and failing optimal medical therapy were recruited at 7 centers in the United States. Patients with severe right heart failure and single-ventricle congenital heart disease were excluded. The primary feasibility endpoint was survival to 30 days without severe stroke or non-operational device failure. RESULTS: Of 7 children implanted, the median age was 2.2 (range 0.7, 7.1) years, median weight 10 (8.2 to 20.7) kilograms; 86% had dilated cardiomyopathy; 29% were INTERMACS profile 1. The median duration of Jarvik 2015 support was 149 (range 5 to 188) days where all 7 children survived including 5 to heart transplant, 1 to recovery, and 1 to conversion to a paracorporeal device. One patient experienced an ischemic stroke on day 53 of device support in the setting of myocardial recovery. One patient required ECMO support for intractable ventricular arrhythmias and was eventually transplanted from paracorporeal biventricular VAD support. The median pump speed was 1600 RPM with power ranging from 1-4 Watts. The median plasma free hemoglobin was 19, 30, 19 and 30 mg/dL at 7, 30, 90 and 180 days or time of explant, respectively. All patients reached the primary feasibility endpoint. Patient-reported outcomes with the device were favorable with respect to participation in a full range of activities. Due to financial issues with the manufacturer, the study was suspended after consent of the eighth patient. CONCLUSION: The Jarvik 2015 LVAD appears to hold important promise as an implantable continuous flow device for smaller children that may support hospital discharge. The FDA has approved the device to proceed to a 22-subject pivotal trial. Whether this device will survive to commercialization remains unclear because of the financial challenges faced by industry seeking to develop pediatric medical devices. (Supported by NIH/NHLBI HHS Contract N268201200001I, clinicaltrials.gov 02954497).


Subject(s)
Feasibility Studies , Heart Failure , Heart-Assist Devices , Humans , Child, Preschool , Child , Male , Infant , Female , Prospective Studies , Heart Failure/therapy , Heart Failure/surgery , Heart Failure/physiopathology , Miniaturization , Prosthesis Design , Treatment Outcome , United States
2.
Am J Cardiol ; 210: 183-187, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-37918818

ABSTRACT

The Fontan Udenafil Exercise Longitudinal (FUEL) trial showed that treatment with udenafil was associated with improved exercise performance at the ventilatory anaerobic threshold in children with Fontan physiology. However, it is not known how the initiation of phosphodiesterase 5 inhibitor therapy affects heart rate and blood pressure in this population. These data may help inform patient selection and monitoring after the initiation of udenafil therapy. The purpose of this study is to evaluate the effects of udenafil on vital signs in the cohort of patients enrolled in the FUEL trial. This international, multicenter, randomized, double-blind, placebo-controlled trial of udenafil included adolescents with single ventricle congenital heart disease who had undergone Fontan palliation. Changes in vital signs (heart rate [HR], systolic [SBP] and diastolic blood pressure [DBP]) were compared both to subject baseline and between the treatment and the placebo groups. Additional exploratory analyses were performed to evaluate changes in vital signs for prespecified subpopulations believed to be most sensitive to udenafil initiation. Baseline characteristics were similar between the treatment and placebo cohorts (n = 200 for each). The groups demonstrated a decrease in HR, SBP, and DBP 2 hours after drug/placebo administration, except SBP in the placebo group. There was an increase in SBP from baseline to after 6-min walk test in the treatment and placebo groups, and the treatment group showed an increase in HR (87.4 ± 15.0 to 93.1 ± 19.4 beats/min, p <0.01) after exercise. When comparing changes from baseline to the 26-week study visit, small decreases in both SBP (-1.9 ± 12.3 mm Hg, p = 0.03) and DBP (-3.0 ± 9.6 mm Hg, p <0.01) were seen in the treatment group. There were no clinically significant differences between treatment and placebo group in change in HR or blood pressure in the youngest age quartile, lightest weight quartile, or those on afterload-reducing agents. In conclusion, initiation of treatment with udenafil in patients with Fontan circulation was not associated with clinically significant changes in vital signs, implying that for patients similar to those enrolled in the FUEL trial, udenafil can be started without the requirement for additional monitoring after initial administration.


Subject(s)
Fontan Procedure , Child , Humans , Adolescent , Blood Pressure , Heart Rate , Sulfonamides/adverse effects , Double-Blind Method
SELECTION OF CITATIONS
SEARCH DETAIL
...