Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 64
Filter
1.
Anaesthesia ; 78(10): 1272-1284, 2023 10.
Article in English | MEDLINE | ID: mdl-37531294

ABSTRACT

International recommendations encourage liberal administration of oxygen to patients having surgery under general anaesthesia, ostensibly to reduce surgical site infection. However, the optimal oxygen regimen to minimise postoperative complications and enhance recovery from surgery remains uncertain. The hospital operating theatre randomised oxygen (HOT-ROX) trial is a multicentre, patient- and assessor-blinded, parallel-group, randomised clinical trial designed to assess the effect of a restricted, standard care, or liberal peri-operative oxygen therapy regimen on days alive and at home after surgery in adults undergoing prolonged non-cardiac surgery under general anaesthesia. Here, we report the findings of the internal vanguard feasibility phase of the trial undertaken in four large metropolitan hospitals in Australia and New Zealand that included the first 210 patients of a planned overall 2640 trial sample, with eight pre-specified endpoints evaluating protocol implementation and safety. We screened a total of 956 participants between 1 September 2019 and 26 January 2021, with data from 210 participants included in the analysis. Median (IQR [range]) time-weighted average intra-operative Fi O2 was 0.30 (0.26-0.35 [0.20-0.59]) and 0.47 (0.44-0.51 [0.37-0.68]) for restricted and standard care, respectively (mean difference (95%CI) 0.17 (0.14-0.20), p < 0.001). Median time-weighted average intra-operative Fi O2 was 0.83 (0.80-0.85 [0.70-0.91]) for liberal oxygen therapy (mean difference (95%CI) compared with standard care 0.36 (0.33-0.39), p < 0.001). All feasibility endpoints were met. There were no significant patient adverse events. These data support the feasibility of proceeding with the HOT-ROX trial without major protocol modifications.


Subject(s)
Oxygen Inhalation Therapy , Oxygen , Adult , Humans , Feasibility Studies , Oxygen Inhalation Therapy/methods , Australia , New Zealand
2.
Phys Med Biol ; 68(4)2023 02 17.
Article in English | MEDLINE | ID: mdl-36716491

ABSTRACT

Objective.Presently electron beam treatments are delivered using dedicated applicators. An alternative is the usage of the already installed photon multileaf collimator (pMLC) enabling efficient electron treatments. Currently, the commissioning of beam models is a manual and time-consuming process. In this work an auto-commissioning procedure for the Monte Carlo (MC) beam model part representing the beam above the pMLC is developed for TrueBeam systems with electron energies from 6 to 22 MeV.Approach.The analytical part of the electron beam model includes a main source representing the primary beam and a jaw source representing the head scatter contribution each consisting of an electron and a photon component, while MC radiation transport is performed for the pMLC. The auto-commissioning of this analytical part relies on information pre-determined from MC simulations, in-air dose profiles and absolute dose measurements in water for different field sizes and source to surface distances (SSDs). For validation calculated and measured dose distributions in water were compared for different field sizes, SSDs and beam energies for eight TrueBeam systems. Furthermore, a sternum case in an anthropomorphic phantom was considered and calculated and measured dose distributions were compared at different SSDs.Main results.Instead of the manual commissioning taking up to several days of calculation time and several hours of user time, the auto-commissioning is carried out in a few minutes. Measured and calculated dose distributions agree generally within 3% of maximum dose or 2 mm. The gamma passing rates for the sternum case ranged from 96% to 99% (3% (global)/2 mm criteria, 10% threshold).Significance.The auto-commissioning procedure was successfully implemented and applied to eight TrueBeam systems. The newly developed user-friendly auto-commissioning procedure allows an efficient commissioning of an MC electron beam model and eases the usage of advanced electron radiotherapy utilizing the pMLC for beam shaping.


Subject(s)
Electrons , Particle Accelerators , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Phantoms, Imaging , Monte Carlo Method , Water
3.
Phys Med Biol ; 68(4)2023 02 13.
Article in English | MEDLINE | ID: mdl-36655485

ABSTRACT

Objective.The computational effort to perform beamlet calculation, plan optimization and final dose calculation of a treatment planning process (TPP) generating intensity modulated treatment plans is enormous, especially if Monte Carlo (MC) simulations are used for dose calculation. The goal of this work is to improve the computational efficiency of a fully MC based TPP for static and dynamic photon, electron and mixed photon-electron treatment techniques by implementing multiple methods and studying the influence of their parameters.Approach.A framework is implemented calculating MC beamlets efficiently in parallel on each available CPU core. The user can specify the desired statistical uncertainty of the beamlets, a fractional sparse dose threshold to save beamlets in a sparse format and minimal distances to the PTV surface from which 2 × 2 × 2 = 8 (medium) or even 4 × 4 × 4 = 64 (large) voxels are merged. The compromise between final plan quality and computational efficiency of beamlet calculation and optimization is studied for several parameter values to find a reasonable trade-off. For this purpose, four clinical and one academic case are considered with different treatment techniques.Main results.Setting the statistical uncertainty to 5% (photon beamlets) and 15% (electron beamlets), the fractional sparse dose threshold relative to the maximal beamlet dose to 0.1% and minimal distances for medium and large voxels to the PTV to 1 cm and 2 cm, respectively, does not lead to substantial degradation in final plan quality compared to using 2.5% (photon beamlets) and 5% (electron beamlets) statistical uncertainty and no sparse format nor voxel merging. Only OAR sparing is slightly degraded. Furthermore, computation times are reduced by about 58% (photon beamlets), 88% (electron beamlets) and 96% (optimization).Significance.Several methods are implemented improving computational efficiency of beamlet calculation and plan optimization of a fully MC based TPP without substantial degradation in final plan quality.


Subject(s)
Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Algorithms , Photons/therapeutic use , Monte Carlo Method
4.
Phys Med Biol ; 67(17)2022 08 18.
Article in English | MEDLINE | ID: mdl-35878610

ABSTRACT

Objective.The purpose of this study is to develop a treatment planning process (TPP) for non-isocentric dynamic trajectory radiotherapy (DTRT) using dynamic gantry rotation, collimator rotation, table rotation, longitudinal, vertical and lateral table translations and intensity modulation and to validate the dosimetric accuracy.Approach.The TPP consists of two steps. First, a path describing the dynamic gantry rotation, collimator rotation and dynamic table rotation and translations is determined. Second, an optimization of the intensity modulation along the path is performed. We demonstrate the TPP for three use cases. First, a non-isocentric DTRT plan for a brain case is compared to an isocentric DTRT plan in terms of dosimetric plan quality and delivery time. Second, a non-isocentric DTRT plan for a craniospinal irradiation (CSI) case is compared to a multi-isocentric intensity modulated radiotherapy (IMRT) plan. Third, a non-isocentric DTRT plan for a bilateral breast case is compared to a multi-isocentric volumetric modulated arc therapy (VMAT) plan. The non-isocentric DTRT plans are delivered on a TrueBeam in developer mode and their dosimetric accuracy is validated using radiochromic films.Main results.The non-isocentric DTRT plan for the brain case is similar in dosimetric plan quality and delivery time to the isocentric DTRT plan but is expected to reduce the risk of collisions. The DTRT plan for the CSI case shows similar dosimetric plan quality while reducing the delivery time by 45% in comparison with the IMRT plan. The DTRT plan for the breast case showed better treatment plan quality in comparison with the VMAT plan. The gamma passing rates between the measured and calculated dose distributions are higher than 95% for all three plans.Significance.The versatile benefits of non-isocentric DTRT are demonstrated with three use cases, namely reduction of collision risk, reduced setup and delivery time and improved dosimetric plan quality.


Subject(s)
Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Phantoms, Imaging , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods
5.
Phys Med Biol ; 66(4): 045006, 2021 02 05.
Article in English | MEDLINE | ID: mdl-32413883

ABSTRACT

PURPOSE: To develop a novel treatment planning process (TPP) with simultaneous optimization of modulated photon, electron and proton beams for improved treatment plan quality in radiotherapy. METHODS: A framework for fluence map optimization of Monte Carlo (MC) calculated beamlet dose distributions is developed to generate treatment plans consisting of photon, electron and spot scanning proton fields. Initially, in-house intensity modulated proton therapy (IMPT) plans are compared to proton plans created by a commercial treatment planning system (TPS). A triple beam radiotherapy (TriB-RT) plan is generated for an exemplary academic case and the dose contributions of the three particle types are investigated. To investigate the dosimetric potential, a TriB-RT plan is compared to an in-house IMPT plan for two clinically motivated cases. Benefits of TriB-RT for a fixed proton beam line with a single proton field are investigated. RESULTS: In-house optimized IMPT are of at least equal or better quality than TPS-generated proton plans, and MC-based optimization shows dosimetric advantages for inhomogeneous situations. Concerning TriB-RT, for the academic case, the resulting plan shows substantial contribution of all particle types. For the clinically motivated case, improved sparing of organs at risk close to the target volume is achieved compared to IMPT (e.g. myelon and brainstem [Formula: see text] -37%) at cost of an increased low dose bath (healthy tissue V 10% +22%). In the scenario of a fixed proton beam line, TriB-RT plans are able to compensate the loss in degrees of freedom to substantially improve plan quality compared to a single field proton plan. CONCLUSION: A novel TPP which simultaneously optimizes photon, electron and proton beams was successfully developed. TriB-RT shows the potential for improved treatment plan quality and is especially promising for cost-effective single-room proton solutions with a fixed beamline in combination with a conventional linac delivering photon and electron fields.


Subject(s)
Electrons , Head and Neck Neoplasms/radiotherapy , Pelvic Neoplasms/radiotherapy , Phantoms, Imaging , Photons/therapeutic use , Proton Therapy/standards , Radiotherapy Planning, Computer-Assisted/standards , Humans , Monte Carlo Method , Proton Therapy/methods , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/standards
6.
Med Phys ; 47(12): 6519-6530, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33075168

ABSTRACT

MOTIVATION: Progress in the field of magnetic resonance (MR)-guided radiotherapy has triggered the need for fast and accurate dose calculation in presence of magnetic fields. The aim of this work is to satisfy this need by extending the macro Monte Carlo (MMC) method to enable dose calculation for photon, electron, and proton beams in a magnetic field. METHODS: The MMC method is based on the transport of particles in macroscopic steps through an absorber by sampling the relevant physical quantities from a precalculated database containing probability distribution functions. To enable MMC particle transport in a magnetic field, a transformation accounting for the Lorentz force is applied for each macro step by rotating the sampled position and direction around the magnetic field vector. The transformed position and direction distributions on local geometries are validated against full MC for electron and proton pencil beams. To enable photon dose calculation, an in-house MC algorithm is used for photon transport and interaction. Emerging secondary charged particles are passed to MMC for transport and energy deposition. The extended MMC dose calculation accuracy and efficiency is assessed by comparison with EGSnrc (photon and electron beams) and Geant4 (proton beam) calculated dose distributions of different energies and homogeneous magnetic fields for broad beams impinging on water phantoms with bone and lung inhomogeneities. RESULTS: The geometric transformation on the local geometries is able to reproduce the results of full MC for all investigated settings (difference in mean value and standard deviation <1%). Macro Monte Carlo calculated dose distributions in a homogeneous magnetic field are in agreement with EGSnrc and Geant4, respectively, with gamma passing rates >99.6% (global 2%, 2 mm and 10% threshold criteria) for all situations. MMC achieves a substantial efficiency gain of up to a factor of 21 (photon beam), 66 (electron beam), and 356 (proton beam) compared to EGSnrc or Geant4. CONCLUSION: Efficient and accurate dose calculation in magnetic fields was successfully enabled by utilizing the developed extended MMC transport method for photon, electron, and proton beams.


Subject(s)
Radiotherapy, Image-Guided , Algorithms , Magnetic Fields , Monte Carlo Method , Phantoms, Imaging , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
7.
Radiat Oncol ; 14(1): 172, 2019 Sep 18.
Article in English | MEDLINE | ID: mdl-31533746

ABSTRACT

BACKGROUND: Vendor-independent Monte Carlo (MC) dose calculation (IDC) for patient-specific quality assurance of multi-leaf collimator (MLC) based CyberKnife treatments is used to benchmark and validate the commercial MC dose calculation engine for MLC based treatments built into the CyberKnife treatment planning system (Precision MC). METHODS: The benchmark included dose profiles in water in 15 mm depth and depth dose curves of rectangular MLC shaped fields ranging from 7.6 mm × 7.7 mm to 115.0 mm × 100.1 mm, which were compared between IDC, Precision MC and measurements in terms of dose difference and distance to agreement. Dose distributions of three phantom cases and seven clinical lung cases were calculated using both IDC and Precision MC. The lung PTVs ranged from 14 cm3 to 93 cm3. Quantitative comparison of these dose distributions was performed using dose-volume parameters and 3D gamma analysis with 2% global dose difference and 1 mm distance criteria and a global 10% dose threshold. Time to calculate dose distributions was recorded and efficiency was assessed. RESULTS: Absolute dose profiles in 15 mm depth in water showed agreement between Precision MC and IDC within 3.1% or 1 mm. Depth dose curves agreed within 2.3% / 1 mm. For the phantom and clinical lung cases, mean PTV doses differed from - 1.0 to + 2.3% between IDC and Precision MC and gamma passing rates were > =98.1% for all multiple beam treatment plans. For the lung cases, lung V20 agreed within ±1.5%. Calculation times ranged from 2.2 min (for 39 cm3 PTV at 1.0 × 1.0 × 2.5 mm3 native CT resolution) to 8.1 min (93 cm3 at 1.1 × 1.1 × 1.0 mm3), at 2% uncertainty for Precision MC for the 7 examined lung cases and 4-6 h for IDC, which, however, is not optimized for efficiency but used as a gold standard for accuracy. CONCLUSIONS: Both accuracy and efficiency of Precision MC in the context of MLC based planning for the CyberKnife M6 system were benchmarked against MC based IDC framework. Precision MC is used in clinical practice at our institute.


Subject(s)
Algorithms , Lung Neoplasms/surgery , Monte Carlo Method , Phantoms, Imaging , Prostatic Neoplasms/surgery , Radiosurgery/instrumentation , Radiosurgery/methods , Benchmarking , Humans , Lung Neoplasms/pathology , Male , Organs at Risk/radiation effects , Prognosis , Prostatic Neoplasms/pathology , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods
8.
AJNR Am J Neuroradiol ; 40(3): 396-400, 2019 03.
Article in English | MEDLINE | ID: mdl-30705072

ABSTRACT

The overwhelming benefit of endovascular therapy in patients with large-vessel occlusions suggests that more patients will be screened than treated. Some of those patients will be evaluated first at primary stroke centers; this type of evaluation calls for standardizing the imaging approach to minimize delays in assessing, transferring, and treating these patients. Here, we propose that CT angiography (performed at the same time as head CT) should be the minimum imaging approach for all patients with stroke with suspected large-vessel occlusion presenting to primary stroke centers. We discuss some of the implications of this approach and how to facilitate them.


Subject(s)
Hospital Units , Neuroimaging/methods , Neuroimaging/standards , Stroke/diagnostic imaging , Aged , Computed Tomography Angiography/methods , Endovascular Procedures , Female , Hospital Units/organization & administration , Hospital Units/standards , Humans , Male , Middle Aged , Patient Transfer , Stroke/therapy , Time-to-Treatment , Tomography, X-Ray Computed , Workflow
9.
Radiat Prot Dosimetry ; 182(1): 18-19, 2018 Dec 01.
Article in English | MEDLINE | ID: mdl-30189021

ABSTRACT

While repairing a biplane cardiovascular X-ray system in a hospital, a service technician accidentally activated the system's floor pedal. He continued his work under unnoticed exposure for about 5 min until the system alarm was automatically activated. About 2 h after the exposure, the technician developed an erythema on parts of his left face and neck. The next day, he reported his incident to the competent authorities and was hospitalised in a unit specialised in treating heavily irradiated patients. Frequent blood analysis did not show any signs for a significant exposure to radiation. The Federal Office of Public Health then conducted extensive dose estimations. It could be shown that the dismounted collimator was always in front of the lateral X-ray tube, shielding the technician from the direct beam. The dose estimations came to the following conservative results: an effective dose of 5 mSv, a skin dose of 200 mSv, an eye lens dose of 100 mSv and an extremity dose (arm) of 700 mSv. The cause of the erythema remains unclear since the estimated doses are thought to be too low to induce any visible effect on the skin.


Subject(s)
Erythema/etiology , Lens, Crystalline/radiation effects , Occupational Exposure/adverse effects , Phantoms, Imaging , Radiation Protection/standards , Skin/radiation effects , X-Rays/adverse effects , Humans , Occupational Exposure/analysis , Personnel, Hospital , Radiation Dosage , Radioactive Hazard Release
10.
Med Phys ; 2018 Jul 10.
Article in English | MEDLINE | ID: mdl-29992574

ABSTRACT

PURPOSE: The purpose of this study was to develop a treatment technique for dynamic mixed beam radiotherapy (DYMBER) utilizing increased degrees of freedom (DoF) of a conventional treatment unit including different particle types (photons and electrons), intensity and energy modulation and dynamic gantry, table, and collimator rotations. METHODS: A treatment planning process has been developed to create DYMBER plans combining photon dynamic trajectories (DTs) and step and shoot electron apertures collimated with the photon multileaf collimator (pMLC). A gantry-table path is determined for the photon DTs with minimized overlap of the organs at risk (OARs) with the target. In addition, an associated dynamic collimator rotation is established with minimized area between the pMLC leaves and the target contour. pMLC sequences of photon DTs and electron pMLC apertures are then simultaneously optimized using direct aperture optimization (DAO). Subsequently, the final dose distribution of the electron pMLC apertures is calculated using the Swiss Monte Carlo Plan (SMCP). The pMLC sequences of the photon DTs are then re-optimized with a finer control point resolution and with the final electron dose distribution taken into account. Afterwards, the final photon dose distribution is calculated also using the SMCP and summed together with the one of the electrons. This process is applied for a brain and two head and neck cases. The resulting DYMBER dose distributions are compared to those of dynamic trajectory radiotherapy (DTRT) plans consisting only of photon DTs and clinically applied VMAT plans. Furthermore, the deliverability of the DYMBER plans is verified in terms of dosimetric accuracy, delivery time and collision avoidance. For this purpose, The DYMBER plans are delivered to Gafchromic EBT3 films placed in an anthropomorphic head phantom on a Varian TrueBeam linear accelerator. RESULTS: For each case, the dose homogeneity in the target is similar or better for DYMBER compared to DTRT and VMAT. Averaged over all three cases, the mean dose to the parallel OARs is 16% and 28% lower, D2% to the serial OARs is 17% and 37% lower and V10% to normal tissue is 12% and 4% lower for the DYMBER plans compared to the DTRT and VMAT plans, respectively. The DYMBER plans are delivered without collision and with a 4-5 min longer delivery time than the VMAT plans. The absolute dose measurements are compared to calculation by gamma analysis using 2% (global)/2 mm criteria with passing rates of at least 99%. CONCLUSIONS: A treatment technique for DYMBER has been successfully developed and verified for its deliverability. The dosimetric superiority of DYMBER over DTRT and VMAT indicates utilizing increased DoF to be the key to improve brain and head and neck radiation treatments in future.

11.
AJNR Am J Neuroradiol ; 39(1): 102-106, 2018 Jan.
Article in English | MEDLINE | ID: mdl-29191873

ABSTRACT

BACKGROUND AND PURPOSE: The safety and efficacy of endovascular therapy for large-artery stroke in the extended time window is not yet well-established. We performed a subgroup analysis on subjects enrolled within an extended time window in the Endovascular Treatment for Small Core and Proximal Occlusion Ischemic Stroke (ESCAPE) trial. MATERIALS AND METHODS: Fifty-nine of 315 subjects (33 in the intervention group and 26 in the control group) were randomized in the ESCAPE trial between 5.5 and 12 hours after last seen healthy (likely to have groin puncture administered 6 hours after that). Treatment effect sizes for all relevant outcomes (90-day mRS shift, mRS 0-2, mRS 0-1, and 24-hour NIHSS scores and intracerebral hemorrhage) were reported using unadjusted and adjusted analyses. RESULTS: There was no evidence of treatment heterogeneity between subjects in the early and late windows. Treatment effect favoring intervention was seen across all clinical outcomes in the extended time window (absolute risk difference of 19.3% for mRS 0-2 at 90 days). There were more asymptomatic intracerebral hemorrhage events within the intervention arm (48.5% versus 11.5%, P = .004) but no difference in symptomatic intracerebral hemorrhage. CONCLUSIONS: Patients with an extended time window could potentially benefit from endovascular treatment. Ongoing randomized controlled trials using imaging to identify late presenters with favorable brain physiology will help cement the paradigm of using time windows to select the population for acute imaging and imaging to select individual patients for therapy.


Subject(s)
Brain Ischemia/therapy , Endovascular Procedures/methods , Aged , Brain Ischemia/diagnostic imaging , Computed Tomography Angiography/methods , Female , Humans , Male , Middle Aged , Time Factors , Tomography, X-Ray Computed/methods , Treatment Outcome
12.
Phys Med Biol ; 63(2): 025017, 2018 01 11.
Article in English | MEDLINE | ID: mdl-29214984

ABSTRACT

Standard electron treatments are currently still performed using standard or molded patient-specific cut-outs placed in the electron applicator. Replacing cut-outs and electron applicators with a photon multileaf collimator (pMLC) for electron beam collimation would make standard electron treatments more efficient and would facilitate advanced treatment techniques like modulated electron radiotherapy (MERT) and mixed beam radiotherapy (MBRT). In this work, a multiple source Monte Carlo beam model for pMLC shaped electron beams commissioned at a source-to-surface distance (SSD) of 70 cm is extended for SSDs of up to 100 cm and validated for several Varian treatment units with field sizes typically used for standard electron treatments. Measurements and dose calculations agree generally within 3% of the maximal dose or 2 mm distance to agreement. To evaluate the dosimetric consequences of using pMLC collimated electron beams for standard electron treatments, pMLC-based and cut-out-based treatment plans are created for a left and a right breast boost, a sternum, a testis and a parotid gland case. The treatment plans consist of a single electron field, either alone (1E) or in combination with two 3D conformal tangential photon fields (1E2X). For each case, a pMLC plan with similar treatment plan quality in terms of dose homogeneity to the target and absolute mean dose values to the organs at risk (OARs) compared to a cut-out plan is found. The absolute mean dose to an OAR is slightly increased for pMLC-based compared to cut-out-based 1E plans if the OAR is located laterally close to the target with respect to beam direction, or if a 6 MeV electron beam is used at an extended SSD. In conclusion, treatment plans using cut-out collimation can be replaced by plans of similar treatment plan quality using pMLC collimation with accurately calculated dose distributions.


Subject(s)
Electrons , Monte Carlo Method , Neoplasms/radiotherapy , Organs at Risk/radiation effects , Phantoms, Imaging , Photons/therapeutic use , Radiotherapy Planning, Computer-Assisted/methods , Humans , Radiometry/methods , Radiotherapy Dosage
13.
Phys Med Biol ; 63(1): 015015, 2017 Dec 19.
Article in English | MEDLINE | ID: mdl-29256450

ABSTRACT

This work aims to develop, implement and validate a Monte Carlo (MC)-based independent dose calculation (IDC) framework to perform patient-specific quality assurance (QA) for multi-leaf collimator (MLC)-based CyberKnife® (Accuray Inc., Sunnyvale, CA) treatment plans. The IDC framework uses an XML-format treatment plan as exported from the treatment planning system (TPS) and DICOM format patient CT data, an MC beam model using phase spaces, CyberKnife MLC beam modifier transport using the EGS++ class library, a beam sampling and coordinate transformation engine and dose scoring using DOSXYZnrc. The framework is validated against dose profiles and depth dose curves of single beams with varying field sizes in a water tank in units of cGy/Monitor Unit and against a 2D dose distribution of a full prostate treatment plan measured with Gafchromic EBT3 (Ashland Advanced Materials, Bridgewater, NJ) film in a homogeneous water-equivalent slab phantom. The film measurement is compared to IDC results by gamma analysis using 2% (global)/2 mm criteria. Further, the dose distribution of the clinical treatment plan in the patient CT is compared to TPS calculation by gamma analysis using the same criteria. Dose profiles from IDC calculation in a homogeneous water phantom agree within 2.3% of the global max dose or 1 mm distance to agreement to measurements for all except the smallest field size. Comparing the film measurement to calculated dose, 99.9% of all voxels pass gamma analysis, comparing dose calculated by the IDC framework to TPS calculated dose for the clinical prostate plan shows 99.0% passing rate. IDC calculated dose is found to be up to 5.6% lower than dose calculated by the TPS in this case near metal fiducial markers. An MC-based modular IDC framework was successfully developed, implemented and validated against measurements and is now available to perform patient-specific QA by IDC.


Subject(s)
Monte Carlo Method , Neoplasms/surgery , Phantoms, Imaging , Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Algorithms , Humans , Radiometry , Radiotherapy Dosage
14.
Anaesth Intensive Care ; 45(5): 611-618, 2017 09.
Article in English | MEDLINE | ID: mdl-28911291

ABSTRACT

Testing for malignant hyperthermia in New Zealand involves two tests-in vitro contracture testing of excised lateral quadriceps muscle and DNA analysis. In vitro contracture testing is regarded as the gold standard in malignant hyperthermia diagnosis but several publications have questioned the reliability of a normal result. Analysis of 479 anaesthetic records in 280 patients or their descendants throughout New Zealand who had tested negative for malignant hyperthermia, demonstrated there was no evidence of malignant hyperthermia episodes in this group who had been administered anaesthetic triggering agents. A wide range of anaesthetics were used over the study period. Analysis of each anaesthetic record was undertaken using the malignant hyperthermia grading scale which determines the likelihood that an anaesthetic event represents a malignant hyperthermia episode. Confirmation of the negative results was further supported by normal DNA analysis of patients in 48% of anaesthetics. There are advantages to using inhalational agents in certain situations and although demonstrating a zero risk of a malignant hyperthermia episode is not statistically possible, evidence in this large series suggests that the risk of an episode in these patients is extremely low and may be negligible. We suggest that anaesthetic triggering agents can be used safely in patients with normal in vitro contracture tests, and in their descendants.


Subject(s)
Anesthetics, Inhalation/adverse effects , Family Health , Malignant Hyperthermia/etiology , Adolescent , Adult , Aged , Aged, 80 and over , Anesthetics, Inhalation/administration & dosage , Child , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Likelihood Functions , Male , Malignant Hyperthermia/diagnosis , Middle Aged , New Zealand , Reproducibility of Results , Young Adult
15.
Phys Med Biol ; 62(14): 5840-5860, 2017 Jun 26.
Article in English | MEDLINE | ID: mdl-28467321

ABSTRACT

The aim of this work is to develop and investigate an inverse treatment planning process (TPP) for mixed beam radiotherapy (MBRT) capable of performing simultaneous optimization of photon and electron apertures. A simulated annealing based direct aperture optimization (DAO) is implemented to perform simultaneous optimization of photon and electron apertures, both shaped with the photon multileaf collimator (pMLC). Validated beam models are used as input for Monte Carlo dose calculations. Consideration of photon pMLC transmission during DAO and a weight re-optimization of the apertures after deliverable dose calculation are utilized to efficiently reduce the differences between optimized and deliverable dose distributions. The TPP for MBRT is evaluated for an academic situation with a superficial and an enlarged PTV in the depth, a left chest wall case including the internal mammary chain and a squamous cell carcinoma case. Deliverable dose distributions of MBRT plans are compared to those of modulated electron radiotherapy (MERT), photon IMRT and if available to those of clinical VMAT plans. The generated MBRT plans dosimetrically outperform the MERT, photon IMRT and VMAT plans for all investigated situations. For the clinical cases of the left chest wall and the squamous cell carcinoma, the MBRT plans cover the PTV similarly or more homogeneously than the VMAT plans, while OARs are spared considerably better with average reductions of the mean dose to parallel OARs and D 2% to serial OARs by 54% and 26%, respectively. Moreover, the low dose bath expressed as V 10% to normal tissue is substantially reduced by up to 45% compared to the VMAT plans. A TPP for MBRT including simultaneous optimization is successfully implemented and the dosimetric superiority of MBRT plans over MERT, photon IMRT and VMAT plans is demonstrated for academic and clinical situations including superficial targets with and without deep-seated part.


Subject(s)
Electrons , Photons/therapeutic use , Radiotherapy, Intensity-Modulated/methods , Humans , Monte Carlo Method , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Time Factors
16.
J Neurointerv Surg ; 9(4): 357-360, 2017 Apr.
Article in English | MEDLINE | ID: mdl-26984868

ABSTRACT

Acute ischemic stroke remains a major public health concern, with low national treatment rates for the condition, demonstrating a disconnection between the evidence of treatment benefit and delivery of this treatment. Intravenous thrombolysis and endovascular thrombectomy are both strongly evidence supported and exquisitely time sensitive therapies. The mismatch between the distribution and incidence of stroke presentations and the availability of specialist care significantly affects access to care. Telestroke, the use of telemedicine for stroke, aims to surmount this hurdle by distributing stroke expertise more effectively, through video consultation with and examination of patients in locations removed from specialist care. This is the first of a detailed two part review, and explores the growth and current practice of telestroke, including the specific role it plays in the assessment and management of patients after emergent large vessel occlusion.


Subject(s)
Stroke/diagnosis , Stroke/therapy , Telemedicine/trends , Disease Management , Humans , Telemedicine/methods , Thrombolytic Therapy/methods , Thrombolytic Therapy/trends
17.
J Neurointerv Surg ; 9(4): 361-365, 2017 Apr.
Article in English | MEDLINE | ID: mdl-26984867

ABSTRACT

Acute ischemic stroke remains a major public health concern, with low national treatment rates for the condition, demonstrating a disconnection between the evidence of treatment benefit and delivery of this treatment. Intravenous thrombolysis and endovascular thrombectomy are both strongly evidence supported and exquisitely time sensitive therapies. The mismatch between the distribution and incidence of stroke presentations and the availability of specialist care significantly affects access to care. Telestroke, the use of telemedicine for stroke, aims to surmount this hurdle by distributing stroke expertise more effectively, through video consultation with and examination of patients in locations removed from specialist care. This is the second of a two part review, and is focused on the challenges telestroke faces for wider adoption. It further details the anticipated evolution of this novel therapeutic platform, and the potential roles it holds in stroke prevention, ambulance based care, rehabilitation, and research.


Subject(s)
Stroke/economics , Stroke/therapy , Telemedicine/economics , Telemedicine/trends , Administration, Intravenous , Endovascular Procedures/economics , Endovascular Procedures/trends , Fibrinolysis , Humans , Stroke/diagnosis , Thrombectomy/economics , Thrombectomy/trends , Thrombolytic Therapy/economics , Thrombolytic Therapy/trends
18.
Radiat Prot Dosimetry ; 170(1-4): 433-6, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27012882

ABSTRACT

Individual monitoring for both external and internal exposures is well regulated in Switzerland. The article gives an overview on the occupational exposure to external radiation of workers based on the data collected in the Swiss national dose registry (NDR) in 2013. The NDR records the monthly doses of radiation workers since the introduction of ICRP 60 recommendations and is manifested in the Swiss ordinance since 1994. Annual dose limits for effective dose are typically exceeded once a year in Switzerland, mostly in medicine. The NDR is a useful optimisation tool to identify and characterise areas with the highest exposures. While exceeded dose limits were often related to accidental acute exposure in the past, they are now more related to continuous exposure during normal work, especially in medicine.


Subject(s)
Occupational Exposure/analysis , Radiation Monitoring/standards , Radiation Protection/standards , Databases, Factual , Government Agencies , Health Physics , Humans , Occupational Exposure/legislation & jurisprudence , Occupational Exposure/prevention & control , Occupational Health/legislation & jurisprudence , Protective Clothing , Radiation Dosage , Registries , Risk Assessment , Switzerland
19.
Med Phys ; 41(12): 121711, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25471958

ABSTRACT

PURPOSE: A beamlet based direct aperture optimization (DAO) for modulated electron radiotherapy (MERT) using photon multileaf collimator (pMLC) shaped electron fields is developed and investigated. METHODS: The Swiss Monte Carlo Plan (SMCP) allows the calculation of dose distributions for pMLC shaped electron beams. SMCP is interfaced with the Eclipse TPS (Varian Medical Systems, Palo Alto, CA) which can thus be included into the inverse treatment planning process for MERT. This process starts with the import of a CT-scan into Eclipse, the contouring of the target and the organs at risk (OARs), and the choice of the initial electron beam directions. For each electron beam, the number of apertures, their energy, and initial shape are defined. Furthermore, the DAO requires dose-volume constraints for the structures contoured. In order to carry out the DAO efficiently, the initial electron beams are divided into a grid of beamlets. For each of those, the dose distribution is precalculated using a modified electron beam model, resulting in a dose list for each beamlet and energy. Then the DAO is carried out, leading to a set of optimal apertures and corresponding weights. These optimal apertures are now converted into pMLC shaped segments and the dose calculation for each segment is performed. For these dose distributions, a weight optimization process is launched in order to minimize the differences between the dose distribution using the optimal apertures and the pMLC segments. Finally, a deliverable dose distribution for the MERT plan is obtained and loaded back into Eclipse for evaluation. For an idealized water phantom geometry, a MERT treatment plan is created and compared to the plan obtained using a previously developed forward planning strategy. Further, MERT treatment plans for three clinical situations (breast, chest wall, and parotid metastasis of a squamous cell skin carcinoma) are created using the developed inverse planning strategy. The MERT plans are compared to clinical standard treatment plans using photon beams and the differences between the optimal and the deliverable dose distributions are determined. RESULTS: For the idealized water phantom geometry, the inversely optimized MERT plan is able to obtain the same PTV coverage, but with an improved OAR sparing compared to the forwardly optimized plan. Regarding the right-sided breast case, the MERT plan is able to reduce the lung volume receiving more than 30% of the prescribed dose and the mean lung dose compared to the standard plan. However, the standard plan leads to a better homogeneity within the CTV. The results for the left-sided thorax wall are similar but also the dose to the heart is reduced comparing MERT to the standard treatment plan. For the parotid case, MERT leads to lower doses for almost all OARs but to a less homogeneous dose distribution for the PTV when compared to a standard plan. For all cases, the weight optimization successfully minimized the differences between the optimal and the deliverable dose distribution. CONCLUSIONS: A beamlet based DAO using multiple beam angles is implemented and successfully tested for an idealized water phantom geometry and clinical situations.


Subject(s)
Neoplasms/radiotherapy , Radiotherapy, Intensity-Modulated/methods , Biophysical Phenomena , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/radiotherapy , Female , Humans , Monte Carlo Method , Neoplasms/diagnostic imaging , Organs at Risk , Parotid Neoplasms/diagnostic imaging , Parotid Neoplasms/radiotherapy , Parotid Neoplasms/secondary , Phantoms, Imaging , Photons/therapeutic use , Radiography , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/statistics & numerical data , Radiotherapy, High-Energy , Radiotherapy, Intensity-Modulated/statistics & numerical data , Thoracic Neoplasms/diagnostic imaging , Thoracic Neoplasms/radiotherapy
20.
Med Phys ; 41(3): 031712, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24593716

ABSTRACT

PURPOSE: This paper describes the development of a forward planning process for modulated electron radiotherapy (MERT). The approach is based on a previously developed electron beam model used to calculate dose distributions of electron beams shaped by a photon multi leaf collimator (pMLC). METHODS: As the electron beam model has already been implemented into the Swiss Monte Carlo Plan environment, the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA) can be included in the planning process for MERT. In a first step, CT data are imported into Eclipse and a pMLC shaped electron beam is set up. This initial electron beam is then divided into segments, with the electron energy in each segment chosen according to the distal depth of the planning target volume (PTV) in beam direction. In order to improve the homogeneity of the dose distribution in the PTV, a feathering process (Gaussian edge feathering) is launched, which results in a number of feathered segments. For each of these segments a dose calculation is performed employing the in-house developed electron beam model along with the macro Monte Carlo dose calculation algorithm. Finally, an automated weight optimization of all segments is carried out and the total dose distribution is read back into Eclipse for display and evaluation. One academic and two clinical situations are investigated for possible benefits of MERT treatment compared to standard treatments performed in our clinics and treatment with a bolus electron conformal (BolusECT) method. RESULTS: The MERT treatment plan of the academic case was superior to the standard single segment electron treatment plan in terms of organs at risk (OAR) sparing. Further, a comparison between an unfeathered and a feathered MERT plan showed better PTV coverage and homogeneity for the feathered plan, with V95% increased from 90% to 96% and V107% decreased from 8% to nearly 0%. For a clinical breast boost irradiation, the MERT plan led to a similar homogeneity in the PTV compared to the standard treatment plan while the mean body dose was lower for the MERT plan. Regarding the second clinical case, a whole breast treatment, MERT resulted in a reduction of the lung volume receiving more than 45% of the prescribed dose when compared to the standard plan. On the other hand, the MERT plan leads to a larger low-dose lung volume and a degraded dose homogeneity in the PTV. For the clinical cases evaluated in this work, treatment plans using the BolusECT technique resulted in a more homogenous PTV and CTV coverage but higher doses to the OARs than the MERT plans. CONCLUSIONS: MERT treatments were successfully planned for phantom and clinical cases, applying a newly developed intuitive and efficient forward planning strategy that employs a MC based electron beam model for pMLC shaped electron beams. It is shown that MERT can lead to a dose reduction in OARs compared to other methods. The process of feathering MERT segments results in an improvement of the dose homogeneity in the PTV.


Subject(s)
Breast Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Algorithms , Calibration , Electrons , Female , Humans , Monte Carlo Method , Normal Distribution , Particle Accelerators , Radiometry , Radiotherapy Dosage , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...