Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
1.
Int J Colorectal Dis ; 29(6): 645-51, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24793212

ABSTRACT

BACKGROUND: Severe courses of Crohn's disease (CD) during pregnancy are rare. However, if occurring, the risk of miscarriage and low birth weight is increased. At present, only limited data is available on the treatment of CD during pregnancy. In particular, there are no standard guidelines for surgical therapy. Nevertheless, surgery is often unavoidable if complications during the course of the disease arise. PURPOSE: This study provides a critical overview of conventional and interventional treatment options for CD complications during pregnancy and analyses the surgical experience gained thus far. For illustrative purposes, clinical cases of three young women with a severe clinical course during pregnancy are presented. METHODS: After treatment-refractory for conservative and interventional measures, surgery remained as the only treatment option. In all cases, a split stoma was created after resection to avoid anastomotic leaks that would endanger the lives of mother and child. The postoperative course of all three patients was uneventful, and pregnancy remained intact until delivery. No further CD specific medication was required before birth. CONCLUSIONS: The management of CD patients during pregnancy requires close interdisciplinary co-operation between gastroenterologists, obstetricians, anaesthetists and visceral surgeons. For the protection of mother and child treatment should thus be delivered in a specialised centre. This article demonstrates the advantages of surgical therapy by focusing on alleviating CD complaints and preventing postoperative complications.


Subject(s)
Crohn Disease/therapy , Patient Care Team , Pregnancy Complications/therapy , Abdominal Abscess/surgery , Abscess/surgery , Adult , Anesthesia/adverse effects , Anti-Bacterial Agents/therapeutic use , Crohn Disease/complications , Crohn Disease/diagnosis , Crohn Disease/surgery , Female , Glucocorticoids/therapeutic use , Humans , Ileal Diseases/surgery , Immunosuppressive Agents/therapeutic use , Intestinal Fistula/surgery , Pregnancy , Pregnancy Complications/diagnosis , Pregnancy Complications/surgery , Remission Induction , Risk Factors , Surgical Stomas , Tumor Necrosis Factor-alpha/antagonists & inhibitors
2.
Open Biomed Eng J ; 4: 16-26, 2010 Feb 04.
Article in English | MEDLINE | ID: mdl-20448794

ABSTRACT

We present a novel technique to predict the outcome of an RF ablation, including the vascular cooling effect. The main idea is to separate the problem into a patient independent part, which has to be performed only once for every applicator model and generator setting, and a patient dependent part, which can be performed very fast. The patient independent part fills a look-up table of the cooling effects of blood vessels, depending on the vessel radius and the distance of the RF applicator from the vessel, using a numerical simulation of the ablation process. The patient dependent part, on the other hand, only consists of a number of table look-up processes. The paper presents this main idea, along with the required steps for its implementation. First results of the computation and the related ex-vivo evaluation are presented and discussed. The paper concludes with future extensions and improvements of the approach.

3.
Eur Radiol ; 19(9): 2302-9, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19424701

ABSTRACT

The purpose of the study was to prospectively evaluate intrahepatic vessel depiction on C-arm CT (CACT) and the influence of the additional combined tissue and three-dimensional vessel visualisation on the positioning of the TACE catheter in comparison to DSA alone. Thirty consecutive patients scheduled for their first transarterial chemoembolisation underwent biphasic CACT and DSA of the liver. After assessing the DSA images for procedure planning, the CACT images were reviewed. The number and origin of the tumour-feeding arteries and the ideal position of the catheter for TACE on both DSA and CACT were assessed and correlated. The number of vessels identified as tumour feeders in each patient was significantly higher using additional CACT than on DSA alone (CACT: 4.0 +/- 1.7; DSA: 3.3 +/- 1.4; P = 0.003, t-test). After considering CACT, in 50% of the patients the catheter position was changed for TACE. Segmental portal vein thrombosis was seen in three patients on CACT, but in only one on DSA. As CACT depicts soft tissue and small vessels with high spatial resolution, tumour vessel allocation is facilitated, and ideal catheter position for TACE can be more accurately identified. The high impact of CACT on the TACE procedure suggests the benefits of its routine use for all patients undergoing their first TACE.


Subject(s)
Antineoplastic Combined Chemotherapy Protocols/administration & dosage , Chemoembolization, Therapeutic/methods , Hepatic Artery/diagnostic imaging , Imaging, Three-Dimensional/methods , Liver Neoplasms/diagnostic imaging , Portal Vein/diagnostic imaging , Tomography, X-Ray Computed/methods , Adult , Aged , Female , Humans , Liver Neoplasms/blood supply , Male , Middle Aged , Radiographic Image Interpretation, Computer-Assisted/methods , Reproducibility of Results , Sensitivity and Specificity , Treatment Outcome , Young Adult
4.
J Gastrointest Surg ; 13(7): 1292-8, 2009 Jul.
Article in English | MEDLINE | ID: mdl-19365694

ABSTRACT

PURPOSE: The staging of anal cancer is extremely important for therapy and prognosis. Transanal endoscopic ultrasound and magnetic resonance imaging are routinely applied. The aim of this prospective comparative study is to evaluate whether tumor staging is concordant between these techniques. METHODS: Forty-five anal cancer patients underwent endoscopic ultrasound and magnetic resonance imaging. Histological confirmation was obtained in all patients. The two test methods were compared with the kappa concordance index and sensitivity for the initial method of tumor detection was calculated. For six patients who were operated upon because of tumor progression, the results were evaluated against the histological tumor stage. RESULTS: High concordance was found in the assessment of tumor size and nodal status (kappa index 0.63 and 0.77). Cancer patients were correctly identified with 100% sensitivity (45/45) by endoscopic ultrasound and with 88.9% (40/45) sensitivity by magnetic resonance imaging. In the six operated patients, T stage was correctly assessed in four of six patients by endoscopic ultrasound and in three of six patients by magnetic resonance imaging. CONCLUSION: The results of endoscopic ultrasound strongly coincide with those of magnetic resonance imaging. Endoscopic ultrasound may be superior to magnetic resonance imaging for detection of small superficial tumors. However, magnetic resonance imaging is needed for N staging.


Subject(s)
Anus Neoplasms/diagnostic imaging , Anus Neoplasms/pathology , Endosonography , Magnetic Resonance Imaging , Neoplasm Staging/methods , Adenocarcinoma/diagnostic imaging , Adenocarcinoma/pathology , Adult , Aged , Aged, 80 and over , Biopsy, Needle , Carcinoma, Squamous Cell/diagnostic imaging , Carcinoma, Squamous Cell/pathology , Cohort Studies , Female , Humans , Immunohistochemistry , Male , Middle Aged , Neoplasm Invasiveness/diagnostic imaging , Neoplasm Invasiveness/pathology , Prospective Studies , Sensitivity and Specificity
5.
Langenbecks Arch Surg ; 394(3): 475-81, 2009 May.
Article in English | MEDLINE | ID: mdl-19274468

ABSTRACT

PURPOSE: To quantify the cooling effect of hepatic vessels on liver radiofrequency (RF) ablation ex situ. METHODS: Bipolar RF applicators (diameter = 1.8 mm, electrode length = 30 mm) were inserted parallel to perfused glass tubes (diameter = 5 and 10 mm; flow = 250-1,800 ml/min) at distances of 5 and 10 mm in porcine livers ex vivo. RF ablation was performed at 30 W/15 kJ. RF lesions were analyzed by measuring the maximum (r (max)) and minimum radius (r (min)) and the lesion area. RESULTS: Glass tubes without flow showed no influence on RF lesions, whereas perfused glass tubes had a significant cooling effect on lesions. r (min) was reduced to 50% at 5 mm applicator-to-vessel distance and the lesion area was reduced from 407 to 321 mm(2) (p < 0.001). There was no significant influence of glass tube diameter or flow volume on any of the analyzed parameters. CONCLUSIONS: Cooling effects of intrahepatic vessels could be simulated in an ex situ model. Cooling effects should be taken into account in RF ablation within 10 mm distance to major liver vessels regardless of blood flow volume or vessel diameter. Surgical RF ablation with temporary blood flow occlusion should be considered in such constellations.


Subject(s)
Catheter Ablation , Cold Temperature , Liver/blood supply , Animals , In Vitro Techniques , Statistics, Nonparametric , Swine
6.
Acta Radiol ; 50(1): 21-7, 2009 Jan.
Article in English | MEDLINE | ID: mdl-19101851

ABSTRACT

BACKGROUND: Magnetic resonance (MR)-guided interventions have evolved from a pure research application to a preclinical method over the last decade. Among the device-tracking techniques, susceptibility artifact-based tracking relies on the contrast between the surrounding blood and the device, and radiofrequency coil-based tracking relies on the local gradient field amplification in a resonating circuit attached to the interventional device. PURPOSE: To evaluate the feasibility and precision of susceptibility artifact-based and microcoil-based MR guidance methods for renal artery stent placement in a swine model. MATERIAL AND METHODS: MR imaging-guided renal artery stent placements were performed in six fully anesthetized pigs using a 1.5T short-bore MR scanner. Susceptibility artifact-based tracking with manual scan-plane adjustments and microcoil tracking with automatic scan-plane adjustments were used for renal artery stent placements in three pigs in each group. With both methods, near real-time steady-state free-precession (SSFP) imaging was used. Differences between the two tracking approaches on stenting time, total procedure time, and stent position were measured. RESULTS: The microcoil-based approach yielded a shorter mean procedure time (17 vs. 23 min). There was no relevant difference for the mean stenting time (12 vs. 13 min). The mean stent deviation from the aortic wall with the susceptibility approach was larger than with the microcoil approach (10 vs. 4.0 mm). CONCLUSION: For MRI-guided renal artery stent placement, the microcoil-based technique had a shorter procedure time and a higher stent placement precision than the susceptibility artifact-based approach.


Subject(s)
Magnetic Resonance Imaging, Interventional/methods , Renal Artery , Stents , Animals , Artifacts , Contrast Media , Iohexol , Software , Swine
8.
Eur Radiol ; 18(8): 1546-55, 2008 Aug.
Article in English | MEDLINE | ID: mdl-18379744

ABSTRACT

The influence of different table feeds (TF) on vascular enhancement and image quality in patients undergoing lower extremity runoff-CTA for peripheral artery occlusive disease (PAOD), acute ischemia (AI) or abdominal aortic aneurysm (AAA) with PAOD was investigated retrospectively. One hundred eighty-five patients (PAOD: n = 132; AI: n = 40; AAA: n = 13) underwent 16-detector runoff-CTA (120 kV; 140 mAs; rotation time 0.5 s, collimation 16 x 1.5 mm) using different TF (30 mm/s: n = 25; 40 mm/s: n = 91; 48 mm/s: n = 36; 56 mm/s: n = 33). Vascular enhancement of the large arteries was measured every 10 cm along the z-axis from the upper abdomen to the toe. Arterial enhancement in the distal lower leg was compared (ANOVA, Bonferroni post-test). Qualitative assessment of bolus timing was performed independently by two radiologists. The study was IRB approved. In patients with PAOD or AI, enhancement of calf arteries using a TF of 48 mm/s (278 +/- 79 HU) was significantly higher in comparison to two slower TF (30 mm/s: 201 +/- 70 HU, P < 0.001; 40 mm/s: 251 +/- 79 HU, P < 0.05; 56 mm/s: 261 +/- 57 HU, NS) and the fewest noninterpretable arterial segments below the knee were observed with a TF of 48 mm/s (reader 1: 5/121 = 4.1%; reader 2: 4/121 = 3.3%). In patients with AAA, the fewest nondiagnostic segments occurred with a TF of 30 mm/s (2/12 = 17%, both readers) and 40 mm/s (4/24 = 17%, both readers). A TF of 48 mm/s provided the best synchronization of CT data acquisition and contrast bolus propagation and thus the best image quality in patients with PAOD and AI. In patients with AAA, a slower TF of 30 mm/s provided better image quality than faster CT protocols.


Subject(s)
Angiography/methods , Aortography/methods , Iliac Artery/diagnostic imaging , Lower Extremity/blood supply , Lower Extremity/diagnostic imaging , Peripheral Vascular Diseases/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Radiographic Image Enhancement/methods , Reproducibility of Results , Sensitivity and Specificity
9.
Ultraschall Med ; 26(4): 277-84, 2005 Aug.
Article in English | MEDLINE | ID: mdl-16123921

ABSTRACT

AIM: SonoVue is the first ultrasound contrast agent which allows repeated continuous examination of the liver in real time. The aim of this study was to compare low mechanical index (MI) real time contrast enhanced ultrasound of the liver, using the contrast agent SonoVue, with conventional B-mode sonography for the detection of hepatic metastases. METHOD: 40 patients with known malignancy and at least one liver lesion on conventional B-mode sonography were included. Conventional B-mode sonography was performed followed by contrast enhanced ultrasound (CEUS) of the liver in the arterial (< 30 sec), portal-venous (40-120 sec) and delayed phase (> 120 sec) after injection of SonoVue. CEUS was performed using contrast specific imaging and low MI (< 0.3). Number, location and size of metastases on baseline and CEUS were compared with CT or MRI (blinded reader). RESULTS: 37 patients had 128 metastases on CT or MRI. Baseline US showed 74 metastases confirmed by reference examination (69%), while CEUS yielded 109 metastases (sensitivity 90%) (p < 0.001). On CEUS, 35 additional metastases not seen on baseline but confirmed by reference imaging were detected in 14 patients (36%). In 8 patients, CEUS showed 13 metastases not seen on reference imaging. CONCLUSION: Detection of hepatic metastases is substantially improved by low MI real time contrast enhanced ultrasound with SonoVue compared to conventional B-mode sonography.


Subject(s)
Contrast Media , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/secondary , Ultrasonography/methods , Aged , Female , Humans , Liver Neoplasms/diagnosis , Liver Neoplasms/pathology , Magnetic Resonance Imaging , Male , Middle Aged , Patient Selection , Sensitivity and Specificity
10.
Rofo ; 176(2): 252-7, 2004 Feb.
Article in German | MEDLINE | ID: mdl-14872381

ABSTRACT

PURPOSE: Exact preoperative determination of the liver volume is of great importance prior to hepatobiliary surgery, especially in living donated liver transplantation (LDLT). In the current literature, a strong correlation between preoperatively calculated and intraoperatively measured liver volumes has been described. Such accuracy seems questionable, primarily due to a difference in the perfusion state of the liver in situ versus after explantation. Purpose of the study was to asses the influence of the perfusion state on liver volume and the validity of the preoperative liver volumetry prior to LDLT. METHODS: In an experimental study, 20 porcine livers were examined. The livers were weighted and their volumes were determined by water displacement prior and after fluid infusion to achieve a pressure physiologically found in the liver veins. The liver volumes in the different perfusion states were calculated based on CT-data. The calculated values were compared with the volume measured by water displacement and the weight of the livers. RESULTS: Assessment of calculated CT volumes and water displacements at identical perfusion states showed a tight correlation and differed on average by 4 +/- 5 %. However, livers before and after fluid infusion showed a 33 +/- 8 % (350 +/- 150 ml) difference in volume. CONCLUSION: CT-volumetry acquires highly accurate data as confirmed by water displacement studies. However, the perfusion state has major impact on liver volume, which has to be accounted for in clinical use.


Subject(s)
Liver Transplantation , Liver/anatomy & histology , Liver/diagnostic imaging , Living Donors , Tomography, X-Ray Computed/methods , Animals , Organ Size , Swine
11.
Radiologe ; 43(4): 301-5, 2003 Apr.
Article in German | MEDLINE | ID: mdl-12721646

ABSTRACT

PURPOSE: Evaluation of clinical relevance of the arterial stimulation procedure with venous sampling (ASVS) in the preoperative localization of insulinoma. METHODS: Thirteen patients with endogenous hyperinsulinism underwent preoperative transabdominal ultrasound (US), helical CT (CT), MRI, endoscopic ultrasound (EUS), and angiography (DSA) in conjunction with the ASVS-test for the detection of insulinoma. The results were compared with intraoperative findings, intraoperative ultrasound (IOUS) and histology. RESULTS: Sensitivity was as follows: US 8%, MRI 27%, CT 46%, EUS 50%,DSA 69%,and ASVS 92%. Intraoperative palpation and IOUS yielded a sensitivity of 77%. In 3 patients the tumors were neither palpable nor detectable by IOUS, the mode of resection was based on preoperative diagnostics. The ASVS procedure as a functional test was superior to all other modalities for the preoperative tumor detection. CONCLUSION: The ASVS was the most sensitive diagnostic modality. It should especially be considered in terms of health economical aspects when CT or MRI do not yield conclusive results.


Subject(s)
Calcium Gluconate , Diagnostic Imaging , Insulinoma/diagnosis , Pancreatic Neoplasms/diagnosis , Adolescent , Adult , Aged , Child , Contraindications , Female , Humans , Insulin/blood , Insulinoma/pathology , Insulinoma/surgery , Male , Middle Aged , Pancreas/pathology , Pancreas/surgery , Pancreatic Neoplasms/pathology , Pancreatic Neoplasms/surgery , Predictive Value of Tests , Ultrasonography, Interventional
12.
Zentralbl Chir ; 128(12): 1093-6, 2003 Dec.
Article in German | MEDLINE | ID: mdl-14750072

ABSTRACT

Angiodysplasia of the colon has been reported as one of the most common sources of lower gastrointestinal bleeding in the elderly whereas it is very rare in younger patients. Apart from this, portal hypertension may also have effects on the colon. There are, however, only a few reports which have investigated the colon in patients with portal hypertension. We report the case of a 16-year-old woman who presented massive bleeding from angiodysplasia of the colon assembled together with portal hypertension due to portal vein thrombosis caused presumably by neonatal umbilical cord infection. In this regard we discuss diagnosis, therapy and prognosis of this disease.


Subject(s)
Arteriovenous Malformations/diagnosis , Colon/blood supply , Gastrointestinal Hemorrhage/etiology , Hypertension, Portal/diagnosis , Portal Vein , Rectum/blood supply , Thrombosis/diagnosis , Adolescent , Arteriovenous Malformations/pathology , Arteriovenous Malformations/surgery , Colon/pathology , Colon/surgery , Colostomy , Diagnosis, Differential , Endoscopy, Gastrointestinal , Esophageal and Gastric Varices/diagnosis , Esophageal and Gastric Varices/pathology , Esophageal and Gastric Varices/surgery , Female , Follow-Up Studies , Gastrointestinal Hemorrhage/pathology , Gastrointestinal Hemorrhage/surgery , Humans , Hypertension, Portal/pathology , Hypertension, Portal/surgery , Magnetic Resonance Imaging , Rectum/pathology , Rectum/surgery , Thrombosis/pathology , Thrombosis/surgery , Ultrasonography, Doppler, Color
13.
BJU Int ; 89(5): 477-87; Quiz i-iii, 2002 Mar.
Article in English | MEDLINE | ID: mdl-11929470

ABSTRACT

The development of new imaging techniques and the refinement of established methods in uroradiological imaging is proceeding rapidly. In the last few years several important developments have been implemented in the routine diagnostic evaluation of urological patients.A milestone is the recent advent of multidetector helical computed tomography (CT), enabling the radiologist to provide the clinician with high-quality three-dimensional (3-D) reconstructions of the urological organs. Powerful workstations are an indispensable tool in the post-processing of CT and magnetic resonance imaging (MRI)data. Significant advances in imaging were obtained in the fields of oncological imaging (e.g. prostate MRI and spectroscopic imaging), paediatric uroradiology(e.g. MR urography) and the evaluation of stone disease by unenhanced helical CT.


Subject(s)
Female Urogenital Diseases/diagnosis , Magnetic Resonance Imaging/methods , Male Urogenital Diseases , Tomography, X-Ray Computed/methods , Urogenital System/injuries , Abdomen, Acute/etiology , Humans , Pelvic Floor
SELECTION OF CITATIONS
SEARCH DETAIL
...