Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Pract Radiat Oncol ; 6(1): e17-24, 2016.
Article in English | MEDLINE | ID: mdl-26603596

ABSTRACT

PURPOSE: The purposes of this study were (1) to evaluate the initial setup accuracy and intrafraction motion for spine stereotactic body radiation therapy (SBRT) using stereotactic body frames (SBFs) and (2) to validate an in-house-developed SBF using a commercial SBF as a benchmark. METHODS AND MATERIALS: Thirty-two spine SBRT patients (34 sites, 118 fractions) were immobilized with the Elekta and in-house (BHS) SBFs. All patients were set up with the Brainlab ExacTrac system, which includes infrared and stereoscopic kilovoltage x-ray-based positioning. Patients were initially positioned in the frame with the use of skin tattoos and then shifted to the treatment isocenter based on infrared markers affixed to the frame with known geometry relative to the isocenter. ExacTrac kV imaging was acquired, and automatic 6D (6 degrees of freedom) bony fusion was performed. The resulting translations and rotations gave the initial setup accuracy. These translations and rotations were corrected for by use of a robotic couch, and verification imaging was acquired that yielded residual setup error. The imaging/fusion process was repeated multiple times during treatment to provide intrafraction motion data. RESULTS: The BHS SBF had greater initial setup errors (mean±SD): -3.9±5.5mm (0.2±0.9°), -1.6±6.0mm (0.5±1.4°), and 0.0±5.3mm (0.8±1.0°), respectively, in the vertical (VRT), longitudinal (LNG), and lateral (LAT) directions. The corresponding values were 0.6±2.7mm (0.2±0.6°), 0.9±5.3mm (-0.2±0.9°), and -0.9±3.0mm (0.3±0.9°) for the Elekta SBF. The residual setup errors were essentially the same for both frames and were -0.1±0.4mm (0.1±0.5°), -0.2±0.4mm (0.0±0.4°), and 0.0±0.4mm (0.0±0.4°), respectively, in VRT, LNG, and LAT. The intrafraction shifts in VRT, LNG, and LAT were 0.0±0.4mm (0.0±0.3°), 0.0±0.5mm (0.0±0.4°), and 0.0±0.4mm (0.0±0.3°), with no significant difference observed between the 2 frames. CONCLUSIONS: These results showed that the combination of the ExacTrac system with either SBF was highly effective in achieving both setup accuracy and intrafraction stability, which were on par with that of mask-based cranial radiosurgery.


Subject(s)
Movement/physiology , Radiosurgery , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Setup Errors/prevention & control , Spinal Neoplasms/surgery , Cone-Beam Computed Tomography , Humans , Immobilization , Organs at Risk/radiation effects , Prognosis , Radiotherapy Dosage , Radiotherapy, Image-Guided , Radiotherapy, Intensity-Modulated
2.
Int J Oncol ; 21(3): 577-82, 2002 Sep.
Article in English | MEDLINE | ID: mdl-12168102

ABSTRACT

With current treatment methods the prognosis for patients with aggressive brain tumors is dismal. Treatment failure is usually due to local recurrence of tumor. Intra-operative photodynamic detection (PDD) of tumor tissue and post-surgical photodynamic therapy (PDT) of the resection cavity may be of benefit. The utility of 5-aminolevulinic acid (ALA) has been recognized in many different treatment fields over the past decade. Following administration of exogenous ALA, the endogenous photosensitizer, protoporphyrin IX (PpIX), accumulates in tumor tissue. A photodynamic effect occurs upon light activation of the target tissue. This article reviews the current preclinical and clinical studies and potential future applications of ALA and its ester-induced PpIX as a photosensitizing agent in the detection and treatment of brain tumors.


Subject(s)
Aminolevulinic Acid/therapeutic use , Brain Neoplasms/drug therapy , Photochemotherapy/methods , Photosensitizing Agents/therapeutic use , Aminolevulinic Acid/pharmacokinetics , Animals , Brain Neoplasms/diagnosis , Brain Neoplasms/metabolism , Brain Neoplasms/surgery , Clinical Trials as Topic , Combined Modality Therapy , Humans , Photosensitizing Agents/pharmacokinetics
SELECTION OF CITATIONS
SEARCH DETAIL
...