Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Vasc Surg ; 75(1): 99-108.e2, 2022 01.
Article in English | MEDLINE | ID: mdl-34425192

ABSTRACT

OBJECTIVE: A crucial step in designing fenestrated stent grafts for treatment of complex aortic abdominal aneurysms is the accurate positioning of the fenestrations. The deployment of a fenestrated stent graft prototype in a patient-specific rigid aortic model can be used for design verification in vitro, but is time and human resources consuming. Numerical simulation (NS) of fenestrated stent graft deployment using the finite element analysis has recently been developed; the aim of this study was to compare the accuracy of fenestration positioning by NS and in vitro. METHODS: All consecutive cases of complex aortic abdominal aneurysm treated with the Fenestrated Anaconda (Terumo Aortic) in six European centers were included in a prospective, observational study. To compare fenestration positioning, the distance from the center of the fenestration to the proximal end of the stent graft (L) and the angular distance from the 0° position (C) were measured and compared between in vitro testing (L1, C1) and NS (L2, C2). The primary hypothesis was that ΔL (|L2 - L1|) and ΔC (|C2 - C1|) would be 2.5 or less mm in more than 80% of the cases. The duration of both processes was also compared. RESULTS: Between May 2018 and January 2019, 50 patients with complex aortic abdominal aneurysms received a fenestrated stent graft with a total of 176 fenestrations. The ΔL and ΔC was 2.5 mm or less for 173 (98%) and 174 (99%) fenestrations, respectively. The NS process duration was significantly shorter than the in vitro (2.1 days [range, 1.0-5.2 days] vs 20.6 days [range, 9-82 days]; P < .001). CONCLUSIONS: Positioning of fenestrations using NS is as accurate as in vitro and could significantly decrease delivery time of fenestrated stent grafts.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Models, Cardiovascular , Postoperative Complications/epidemiology , Stents/adverse effects , Aorta, Abdominal/anatomy & histology , Aorta, Abdominal/diagnostic imaging , Aorta, Abdominal/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Computer Simulation , Humans , Models, Anatomic , Postoperative Complications/etiology , Postoperative Complications/prevention & control , Prospective Studies , Prosthesis Design , Treatment Outcome
2.
Eur J Vasc Endovasc Surg ; 60(1): 16-25, 2020 Jul.
Article in English | MEDLINE | ID: mdl-32184061

ABSTRACT

OBJECTIVE: A significant decrease in aneurysm related survival is observed at long term follow up after infrarenal endovascular aneurysm repair (EVAR) compared with open repair. Therefore, longer term results with new generation endografts are essential. The aim of this post-approval French multicentre prospective observational study (EPI-ANA-01) was to evaluate the technical success and five year mortality and secondary intervention rates of the third generation AnacondaTM endograft. METHODS: From June 2012 to October 2013, 176 consecutive unruptured infrarenal abdominal aortic aneurysms were included (160 male patients, mean age 75.3 ± 8.4 years). Survival, freedom from type Ia endoleak, limb events, and re-interventions were estimated using the Kaplan-Meier method. Anatomical and clinical characteristics were compared according to the occurrence of migration, conversion, adverse limb events, endoleak, and sac enlargement. RESULTS: The primary technical and clinical success rates were 98.3% and 94.9%, respectively. A hostile neck was identified in 33.9% of patients and 10.7% were treated outside instructions for use (IFU). An early post-operative (≤30 days) mortality rate of 1.7% was observed. At one and five years, respectively, the overall survival rate was 94.9% and 65.9% (aneurysm related in four patients [2.3%]) and the clinical success rate was 90.9% and 70.6%. Secondary interventions were performed in 35 of 176 patients (19.9%). The overall limb occlusion rate was 7.9% and the aneurysm sac diameter decreased significantly (pre-operative diameter 53.9 ± 8.6 mm vs. 42.3 ± 14.7 mm at five years; p < .001). Patients treated outside the instructions for use (IFU) had significantly higher rates of migration, surgical conversion, and aneurysm sac expansion (p = .03). CONCLUSION: The Anaconda endograft provides high technical success and satisfactory five year aneurysm exclusion and clinical success rates. However, implantation outside the IFU should be avoided, as it leads to significantly worse outcomes, and caution over the risk of limb occlusion and distal embolisation should be observed.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures , Aged , Aortic Aneurysm, Abdominal/mortality , Blood Vessel Prosthesis/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/mortality , Endoleak/epidemiology , Endoleak/etiology , Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Endovascular Procedures/mortality , Female , France , Humans , Male , Prospective Studies , Registries , Survival Analysis , Treatment Outcome
3.
Ann Vasc Surg ; 43: 151-165, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28495540

ABSTRACT

BACKGROUND: Most of the experience on fenestrated endovascular aneurysm repair involves the custom-made Zenith® endograft (Cook). The fenestrated Anaconda® endograft (Vascutek) was introduced with the potential advantages of complete repositioning and lack of stent material on the main aortic body for more versatility. However, few data are available. Our objective was to assess its mid-term results in the treatment of complex aortic aneurysms. METHODS: Consecutive patients treated with the custom-made fenestrated Anaconda endograft in France and the Principality of Monaco, from December 2010 to October 2015, were included. RESULTS: Eighty-six patients were included over 16 centers (82 men, mean age 73.4 ± 8.1 years, 16 (18.6%) symptomatic aneurysms). The repositioning system was used in 68 cases (79.1%). Two hundred ninety-two visceral/renal vessels were targeted, with a mean number of 3.4 ± 0.6 target vessels/patient and a successful reconstruction in 99.3% of the cases (290/292 vessels). Perioperative technical success was achieved in 86.0% (74/86 patients). In-hospital and 30-day mortality rates were 3.5% (3 patients) and 7.0% (6 patients), respectively. At 12 and 24 months, estimated overall survival rate was 88.3% and 85.2%, target vessel's patency rate was 97.2% and 96.3%, and freedom from aneurysm-related reintervention rate was 96.3% and 88.0%, respectively. At 24 months, there were 7 type II endoleaks (12.7%) and a significant reduction in aneurysm maximum transverse diameter in 70.4%. Five limb occlusions occurred at 1-year and 1 at 2-year follow-up (7.0%). CONCLUSIONS: The fenestrated Anaconda stent-graft system offers acceptable technical success rates, mid-term efficacy, and durability with respect to aneurysm sac regression, target vessel patency, overall mortality, and reintervention rates. Long-term results are still awaited, until then, the rate of graft limb occlusion is of concern and should be further investigated, especially in case of particularly complex aortic anatomies.


Subject(s)
Aortic Diseases/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Stents , Aged , Aged, 80 and over , Aortic Diseases/diagnostic imaging , Aortic Diseases/mortality , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Computed Tomography Angiography , Disease-Free Survival , Endoleak/etiology , Endoleak/therapy , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Female , France , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/therapy , Hospital Mortality , Humans , Kaplan-Meier Estimate , Length of Stay , Male , Monaco , Prosthesis Design , Registries , Retreatment , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...