Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Bull Entomol Res ; 107(6): 724-733, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28424101

ABSTRACT

Adulticides applied against mosquitoes can reduce vector populations during times of high arbovirus transmission. However, impacts of these insecticides on pollinators and other non-target organisms are of concern to mosquito control professionals, beekeepers and others. We evaluated mortality of Culex quinquefasciatus and Apis mellifera when caged insects were exposed to low and high label rates of four common adulticides (Aqua-Pursuit™ [permethrin], Duet® [prallethrin + sumithrin], Fyfanon® [malathion] and Scourge® [resmethrin]) at six distances up to 91.4 m from a truck-mounted ultra-low-volume sprayer. Honey bee mortality was both absolutely low (61 m had limited impacts on honey bee mortality while providing effective mosquito control.


Subject(s)
Bees , Insecticides/administration & dosage , Mosquito Control , Animals , Culex , Female , Toxicity Tests
2.
J Am Mosq Control Assoc ; 24(4): 550-9, 2008 Dec.
Article in English | MEDLINE | ID: mdl-19181064

ABSTRACT

Droplet size spectra from different sprayers used to generate insecticide-laden fogs for controlling flying insects were measured by a laser diffraction instrument and Teflon-coated slides. The objectives of this work were to present not only information on spray-system droplet size generated by different sprayers, but to compare methodologies by which other similar systems can be evaluated and give applicators sprayer-system performance data. Data from 45 replicated spray tests, comprising 11 sprayers and 5 pesticides, showed a wide range in the droplet size spectra produced. The volume median diameter measurements ranged from 2.6 to 75.5 microm for diesel-diluted sprays and from 27.9 to 59.9 microm for water-diluted sprays. Similarly, the percent volume <20 microm ranged between 12.0-100% and 8.5-30.7%, for diesel- and water-diluted sprays, respectively. The droplet sizes measured by the swinging slide and laser diffraction methods were not consistent. The information presented aids users in sprayer selection and operation to produce the specific droplet size spectra required for a particular application.


Subject(s)
Insect Control/instrumentation , Insect Vectors , Pesticides/chemistry , Animals , Fumigation/methods , Insect Control/methods , Nebulizers and Vaporizers , Particle Size , Temperature
3.
J Am Mosq Control Assoc ; 23(3): 321-9, 2007 Sep.
Article in English | MEDLINE | ID: mdl-17939514

ABSTRACT

The control of medically important arthropod vectors of human and animal disease is a high priority for both public health and military officials. Because droplet size of pesticide spray material is a critical factor affecting vector control applications, the droplet-size spectra produced by 11 sprayers and 3 spray formulations were evaluated. Droplet-size spectra were measured by a laser diffraction instrument, a hot-wire system, and rotating slides. There were considerable differences in the droplet-size spectra produced by the different sprayers tested. The volume median diameter (Dv0.5) for the water-based sprays ranged from 4.7 to 211 microm, depending on the sprayer, and the percent of spray volume contained in droplets less than 20 microm (%vol <20 microm) ranged between 0.5% and 98.9%. The Dv0.5 measurements for the oil-based sprays ranged from 9.4 to 125.3 microm and the %vol <20 microm ranged between 2.4% and 97.9%. The correlations between the Dv0.5 measured by the laser system (Dv0.5-laser) and the mass median diameter, Sauter diameter, and Dv0.5 measured by the AIMS probe were all significant. Generally, the slide Dv0.5s were numerically similar to the Dv0.5 from the laser system and the Sauter diameter from the Army Insecticide Measuring System probe. There was less consistent agreement between the % <32 microm values obtained from the slides and those from the other 2 samplers. The information presented can be used by applicators to select the sprayer that produces the droplet-size spectra needed for their particular application situation.


Subject(s)
Mosquito Control/instrumentation , Nebulizers and Vaporizers , Insecticides/chemistry , Lasers , Motor Vehicles , Polytetrafluoroethylene
SELECTION OF CITATIONS
SEARCH DETAIL
...