1.
J Prosthet Dent ; 2024 Jul 10.
Article in English | MEDLINE | ID: mdl-38991886

ABSTRACT

STATEMENT OF PROBLEM: Conventional impression techniques for complete arch implant-supported fixed dental prostheses (CIFDPs) are technique sensitive. Stereophotogrammetry (SPG) and intraoral scanning (IOS) may offer alternatives to conventional impression making. PURPOSE: The purpose of this in vitro study was to assess the accuracy and passive fit of IOS with prefabricated aids, SPG, and open tray impression (OI) for CIFDPs with different implant distributions. MATERIAL AND METHODS: Three definitive casts with 4 parallel implants (4-PARA), 4 inclined implants (4-INCL), and 6 parallel implants (6-PARA) were fabricated. Three recording techniques were tested: IOS with prefabricated aids, SPG, and OI. The best and the worst scans were selected to fabricate 18 milled aluminum alloy frameworks. The trueness and precision of distance deviation (∆td and ∆pd), angular deviation (∆tθand ∆pθ), root mean square errors (∆tRMS for ∆pRMS), and passive fit score of frameworks were recorded. Two-way ANOVA was applied. RESULTS: SPG showed the best trueness and precision (95%CI of ∆td/∆tθ/∆tRMS, 31 to 39 µm, 0.22 to 0.28 degrees, 20 to 23 µm; 95%CI of ∆pd/∆pθ/∆pRMS, 9 to 11 µm, 0.06 to 0.08 degrees, 8 to 10 µm), followed by OI (61 to 83 µm, 0.33 to 0.48 degrees, 28 to 48 µm; 66 to 81 µm, 0.29 to 0.38 degrees, 32 to 41 µm) and IOS (143 to 193 µm, 0.37 to 0.50 degrees, 81 to 96 µm; 89 to 111 µm, 0.27 to 0.31 degrees, 51 to 62 µm). Tilted implants were associated with increased distance deviation. Increased implant number was associated with improved recording precision. The passive fit of frameworks was negatively correlated with the RMS error, and the correlation coefficient was -0.65 (P=.003). CONCLUSIONS: SPG had the best accuracy. Implant distributions affected implant precision. The RMS error can be used to evaluate the passive fit of frameworks.

2.
Article in English | MEDLINE | ID: mdl-37746813

ABSTRACT

OBJECTIVES: The aim of this clinical study was to compare the accuracy of intraoral scan system (IOS) with prefabricated aids and stereophotogrammetry (SPG) compared with open tray implant impression (OI) for complete-arch implant-supported fixed dental prostheses (CIFDP). MATERIALS AND METHODS: Patients needing CIFDP were enrolled in this study. OI, reference standard, IOS with prefabricated aids, and SPG were performed for each patient. Distance and angle deviations between all pairs of abutment analogs, root mean square (RMS) errors between the aligned test and reference model, and chairside time were measured. The effect of inter-abutment distance, jaw (maxilla or mandible), number of implants, and arch length on deviations was analyzed. The mixed effect model was applied to analyze deviations and RMS errors. RESULTS: Fifteen consecutive individuals (6 females and 9 males, 47-77 years old) with 22 arches (9 upper and 13 lower jaws) and 115 implants were included. There was no significant difference in distance deviation comparing SPG and IOS with OI (p > .05). IOS showed a significantly greater angle deviation and RMS errors than SPG (median 0.40° vs. 0.31°, 69 µm vs. 45 µm, p < .01). The inter-abutment distance was negatively correlated with the accuracy of SPG and IOS (p < .05). The chairside time for IOS, SPG, and OI was 10.49 ± 3.50, 14.71 ± 2.86, and 20.20 ± 3.01 min, respectively (p < .01). CONCLUSIONS: The accuracy of SPG and IOS with prefabricated aids was comparable. IOS was the most efficient workflow.

3.
Environ Pollut ; 245: 883-888, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30508791

ABSTRACT

The concentrations, congener profiles and spatial distribution of 13 phthalate esters (PAEs) in the freshwater fish ponds in the Pearl River Delta (PRD) region were investigated in water and sediment samples collect from 22 sites during Jul. 2016-Sept. 2017. The di-2-ethylhexyl phthalate (DEHP) was the predominant compounds in both water and sediment samples, accounting for 70.1% and 66.1% of ∑PAEs, respectively. The DEHP concentrations in the water samples collected from the sites of Zhongshan (35.7 µg/L), Jingmen (17.3 µg/L) and Nanhai (14.2 µg/L) were higher than that collected from other sampling sites (p <0.05), and exceed the Chinese environmental quality standards for surface water (DEHP, 8.00 µg/L). The concentrations of ΣPAEs (mean and median were 11.8 mg/kg dw and 7.95 mg/kg dw) in sediment was higher than that in sediment of river and estuary in the PRD region (p <0.05). The median concentrations of DEHP and di-n-butyl phthalate (DBP) exceeded recommend environmental risk limit (ERL) that posed a potential risk to the aquaculture fish pond environment in the PRD.


Subject(s)
Aquaculture , Environmental Monitoring , Esters/analysis , Phthalic Acids/analysis , Water Pollutants, Chemical/analysis , China , Dibutyl Phthalate/analysis , Diethylhexyl Phthalate/analysis , Estuaries , Ponds , Rivers , Seafood