Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Lett ; 43(2): 202-205, 2018 Jan 15.
Article in English | MEDLINE | ID: mdl-29328238

ABSTRACT

A 2 µm Ho-doped ytrrium lithium fluoride (Ho:YLF) laser end-pumped by a 1.94 µm Tm:fiber laser was developed. A laser system of a ring resonator oscillator and amplifier was operated at repetition rates of 200-5000 Hz at room temperature. The Q-switched outputs were 7.4 W at 5000 Hz and 4.25 W at 200 Hz. Injection seeding was applied to the ring resonator, and single-mode laser emission was obtained. The Tm:fiber-laser-pumped Ho:YLF laser was first used for Doppler wind lidar measurements, and wind profiles were obtained up to ranges of about 15 km in a range resolution of 96 m and an integration time of 1 s.

2.
Appl Opt ; 54(26): 7865-9, 2015 Sep 10.
Article in English | MEDLINE | ID: mdl-26368956

ABSTRACT

Q-switched operation of a diode-side-pumped, conduction-cooled Tm,Ho:YLF laser oscillator with 100-mJ output at a pulse repetition rate of 20 Hz and an eye-safe wavelength of 2-µm was achieved. The noncomposite Tm,Ho:YLF laser rod was conduction-cooled down to -80°C through thermal contact of In films from Cu heat sinks, and the laser diode arrays were conduction-cooled to approximately 20°C using Cu heat sinks in a vacuum container. A ring resonator of 3.86 m length with an acousto-optic Q-switch was used. The pulse width was 125 ns, and optical-to-optical efficiency was approximately 7% for an output of 100 mJ. The laser is used at 2.05 µm for applications of Doppler wind lidar measurements, CO2 differential absorption lidar measurements, and aerosol profiling.

3.
Appl Opt ; 49(10): 1809-17, 2010 Apr 01.
Article in English | MEDLINE | ID: mdl-20357863

ABSTRACT

A coherent 2 microm differential absorption and wind lidar (Co2DiaWiL) was developed to measure CO(2) concentration and line-of-sight wind speed. We conductively cooled a pumping laser head to -80 degrees C and diode arrays to approximately 20 degrees C. A Q-switched laser outputs an energy of 80 mJ (pulse width 150 ns (FWHM), pulse repetition frequency up to 30 Hz). CO(2) measurements made over a column range (487-1986 m) for 5 min accumulation time pairs achieved 0.7% precision. Line-of-sight wind speeds for ranges up to approximately 20 km and returns from a mountainside located 24 km away from the Co2DiaWiL were obtained.

SELECTION OF CITATIONS
SEARCH DETAIL
...