Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Compendium ; 12(5): 348, 350-1, 1991 May.
Article in English | MEDLINE | ID: mdl-1933985

ABSTRACT

The presence of two dissimilar metals in the mouth acting as electrodes, with saliva serving as an electrolyte, can generate an intraoral electric current known as galvanic action. The result of these circuits is usually a transient, unpleasant feeling in the mouth, but occasionally other tissues in the body can be affected. This article presents a report of a patient with a presumable galvanic action that began with the insertion of orthodontic appliances and developed into a serious, debilitating illness.


Subject(s)
Electrogalvanism, Intraoral , Orthodontic Appliances/adverse effects , Ataxia , Female , Gold Alloys , Humans , Hypersensitivity , Middle Aged , Stainless Steel , Tremor
2.
Appl Environ Microbiol ; 48(2): 425-30, 1984 Aug.
Article in English | MEDLINE | ID: mdl-6385851

ABSTRACT

Flocculation and removal of bacteria were observed during two separate aluminum sulfate (alum) treatments for removal of phosphorus from a eutrophic recreational lake. In addition, die-off and release of bacteria from alum floc were studied in columns under laboratory conditions. Membrane filtration and spread plates were used to determine concentrations of indicator species and total cultivatable bacteria, respectively. During the alum treatment of the lake, 90% of the fecal coliform (FC) population and ca. 70% of the fecal streptococci population were removed from the water column within 72 h. Numbers of FC in the floc on the lake bottom exceeded 2,400/100 ml at 120 h compared with the pretreatment concentration of 30 FC/100 ml. Inactivation of FC in the floc proceeded at a rate of 200 FC/100 ml per 24 h. In a second alum application to the lake, 95% of the total culturable bacterial population was removed from the water column. In a laboratory column study of survival and release rates, over 90% of an Escherichia coli suspension was concentrated in a floc formed at the bottom. E. coli was not released from the floc. The numbers of and survival of E. coli in the floc suggest the probable concentration of other enteric organisms, including pathogens. Thus, the floc poses a potential human health risk if ingested by swimmers or if others use the lake as a potable water source.


Subject(s)
Alum Compounds , Aluminum/toxicity , Bacteria/drug effects , Sulfates/toxicity , Water Microbiology , Escherichia coli/drug effects , Escherichia coli/isolation & purification , Fresh Water , Humans , Recreation , Washington
SELECTION OF CITATIONS
SEARCH DETAIL