Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
Add more filters










Publication year range
1.
Acta Biomater ; 159: 63-73, 2023 03 15.
Article in English | MEDLINE | ID: mdl-36708849

ABSTRACT

A methodology for the development of a finite element numerical model of the tympanic membrane (TM) based on experiments carried out in the time domain on a cadaveric human temporal bone is presented. Using a high-speed digital holographic (HDH) system, acoustically-induced transient displacements of the TM surface are obtained. The procedure is capable to generate and validate the finite element model of the TM by numerical and experimental data correlation. Reverse engineering approach is used to identify key material parameters that define the mechanical response of the TM. Finally, modal numerical simulations of the specimen are performed. Results show the feasibility of the methodology to obtain an accurate model of a specific specimen and to help interpret its behaviour with additional numerical simulations. STATEMENT OF SIGNIFICANCE: Improving knowledge of the dynamic behavior of the tympanic membrane is key to understanding the sound transmission system in human hearing and advance in the treatment of its pathologies. Recently we acquired a new tool to carry out experiments in transient regime by means of digital laser holography, capable of providing a large amount of information in a controlled transient test. In this work, these data are used to develop a methodology that generates a numerical model of the tympanic membrane based on numerical-experimental correlations. It is important to be able to develop models that fit specific patients. In this work, additional modal simulations are also presented that, in addition to validating the results, provide more information on the specimen.


Subject(s)
Holography , Tympanic Membrane , Humans , Tympanic Membrane/physiology , Holography/methods , Vibration , Sound , Finite Element Analysis
2.
Int J Mech Sci ; 1982021 May 15.
Article in English | MEDLINE | ID: mdl-34565830

ABSTRACT

We propose a novel material characterization method to estimate the Young's modulus of thin 2-D structures using non-modal noisy single frequency harmonic vibration data measured with holography. The method uses finite-difference discretization to apply the plate equation to all measured pixels inside the boundary of the vibrating structure and then treats the problem as a Bayesian optimization process to find the value of the Young's modulus by minimizing the Euclidian distance between the measured displacement field and repeatedly calculated displacement field using the plate equation. In order to assess the accuracy of the method, ground truth harmonic displacement magnitude fields of different plates were obtained using analytical solutions and the finite-element method and were used to estimate the Young's moduli. We applied Gaussian and non-Gaussian noise with different intensities to assess the robustness and accuracy of the proposed material characterization method in the presence of noise. We demonstrated that for multiple benchmarks for signal to noise ratio of down to 0 dB, our proposed method had errors of less than 5%. We also quantified the effects of uncertainties in the geometrical and material parameters as well as boundary conditions on the estimated Young's modulus. Furthermore, we studied the effects of the mesh size on the runtime and applied the method to experimental holography vibration measurement data of a copper plate.

3.
Opt Express ; 28(17): 24614-24628, 2020 Aug 17.
Article in English | MEDLINE | ID: mdl-32907000

ABSTRACT

The shape of the tympanic membrane (TM) plays an important role in sound transmission through the ear for hearing. Previously we developed a high-speed holographic system employing a tunable wavelength laser for rapid TM shape measurement. However, the tunable laser illumination was not sufficient to measure the shape of the unpainted TM due to the semi-transparency of the TM and short exposure time of the camera. This paper presents a new multiple angle illumination technique that allows us to use a higher power single wavelength laser to perform shape measurements on the unpainted TM. Accuracy of the new method is demonstrated by a measure of a step gauge provided by the National Institute of Standards and Technology. We successfully applied the new shape measurement method on a fresh postmortem human TM without any paint.

4.
Appl Sci (Basel) ; 9(14)2019 Jul 02.
Article in English | MEDLINE | ID: mdl-32802482

ABSTRACT

To improve the understanding of the middle-ear hearing mechanism and assist in the diagnosis of middle-ear diseases, we are developing a high-speed digital holographic (HDH) system to measure the shape and acoustically-induced transient displacements of the tympanic membrane (TM). In this paper, we performed measurements on cadaveric human ears with simulated common middle-ear pathologies. The frequency response function (FRF) of the normalized displacement by the stimulus (sound pressure) at each measured pixel point of the entire TM surface was calculated and the complex modal indicator function (CMIF) of the middle-ear system based on FRFs of the entire TM surface motions was used to differentiate different middle-ear pathologies. We also observed changes in the TM shape and the surface motion pattern before and after various middle-ear manipulations. The observations of distinguishable TM shapes and motion patterns in both time and frequency domains between normal and experimentally simulated pathological ears support the development of a quantitative clinical holography-based apparatus for diagnosing middle-ear pathologies.

5.
J Biomed Opt ; 24(3): 1-12, 2018 09.
Article in English | MEDLINE | ID: mdl-30255670

ABSTRACT

The conical shape of the tympanic membrane (TM or eardrum) plays an important role in its function, such that variations in shape alter the acoustically induced motions of the TM. We present a method that precisely determines both shape and acoustically induced transient response of the entire TM using the same optics and maintaining the same coordinate system, where the TM transient displacements due to a broadband acoustic click excitation (50-µs impulse) and the shape are consecutively measured within <200 ms. Interferograms gathered with continuous high-speed (>2 kHz) optical phase sampling during a single 100-ms wavelength tuning ramp allow precise and rapid reconstructions of the TM shape at varied resolutions (50 to 200 µm). This rapid acquisition of full-field displacements and shape is immune to slow disturbances introduced by breathing or heartbeat of live subjects. Knowledge of TM shape and displacements enables the estimation of surface normal displacements regardless of the orientation of the TM within the measurement system. The proposed method helps better define TM mechanics and provides TM structure and function information useful for the diagnosis of ear disease.


Subject(s)
Holography/methods , Interferometry/methods , Tympanic Membrane/physiology , Acoustic Stimulation/methods , Humans , Vibration
6.
J Acoust Soc Am ; 139(1): 104-17, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26827009

ABSTRACT

Computer-controlled digital holographic techniques are developed and used to measure shape and four-dimensional nano-scale displacements of the surface of the tympanic membrane (TM) in cadaveric human ears in response to tonal sounds. The combination of these measurements (shape and sound-induced motions) allows the calculation of the out-of-plane (perpendicular to the surface) and in-plane (tangential) motion components at over 1,000,000 points on the TM surface with a high-degree of accuracy and sensitivity. A general conclusion is that the in-plane motion components are 10-20 dB smaller than the out-of-plane motions. These conditions are most often compromised with higher-frequency sound stimuli where the overall displacements are smaller, or the spatial density of holographic fringes is higher, both of which increase the uncertainty of the measurements. The results are consistent with the TM acting as a Kirchhoff-Love's thin shell dominated by out-of-plane motion with little in-plane motion, at least with stimulus frequencies up to 8 kHz.


Subject(s)
Movement/physiology , Tympanic Membrane/physiology , Acoustic Stimulation , Cadaver , Female , Humans , Interferometry , Male , Middle Aged , Sound , Sound Spectrography , Temporal Bone/physiology , Tympanic Membrane/anatomy & histology , Vibration
7.
Hear Res ; 340: 15-24, 2016 10.
Article in English | MEDLINE | ID: mdl-26880098

ABSTRACT

The response of the tympanic membrane (TM) to transient environmental sounds and the contributions of different parts of the TM to middle-ear sound transmission were investigated by measuring the TM response to global transients (acoustic clicks) and to local transients (mechanical impulses) applied to the umbo and various locations on the TM. A lightly-fixed human temporal bone was prepared by removing the ear canal, inner ear, and stapes, leaving the incus, malleus, and TM intact. Motion of nearly the entire TM was measured by a digital holography system with a high speed camera at a rate of 42 000 frames per second, giving a temporal resolution of <24 µs for the duration of the TM response. The entire TM responded nearly instantaneously to acoustic transient stimuli, though the peak displacement and decay time constant varied with location. With local mechanical transients, the TM responded first locally at the site of stimulation, and the response spread approximately symmetrically and circumferentially around the umbo and manubrium. Acoustic and mechanical transients provide distinct and complementary stimuli for the study of TM response. Spatial variations in decay and rate of spread of response imply local variations in TM stiffness, mass, and damping.


Subject(s)
Acoustic Stimulation , Ear, Middle/physiology , Tympanic Membrane/physiology , Cadaver , Ear Canal , Holography/methods , Humans , Incus/physiology , Malleus/physiology , Motion , Sound , Stapes/physiology , Temporal Bone , Time Factors , Vibration
8.
J Biomed Opt ; 20(11): 111202, 2015.
Article in English | MEDLINE | ID: mdl-25984986

ABSTRACT

Holographic interferometric methods typically require the use of three sensitivity vectors in order to obtain three-dimensional (3-D) information. Methods based on multiple directions of illumination have limited applications when studying biological tissues that have temporally varying responses such as the tympanic membrane (TM). Therefore, to measure 3-D displacements in such applications, the measurements along all the sensitivity vectors have to be done simultaneously. We propose a multiple-illumination directions approach to measure 3-D displacements from a single-shot hologram that contains displacement information from three sensitivity vectors. The hologram of an object of interest is simultaneously recorded with three incoherently superimposed pairs of reference and object beams. The incident off-axis angles of the reference beams are adjusted such that the frequency components of the multiplexed hologram are completely separate. Because of the differences in the directions and wavelengths of the reference beams, the positions of each reconstructed image corresponding to each sensitivity vector are different. We implemented a registration algorithm to accurately translate individual components of the hologram into a single global coordinate system to calculate 3-D displacements. The results include magnitudes and phases of 3-D sound-induced motions of a human cadaveric TM at several excitation frequencies showing modal and traveling wave motions on its surface.


Subject(s)
Holography/methods , Imaging, Three-Dimensional/methods , Tympanic Membrane/anatomy & histology , Tympanic Membrane/physiology , Algorithms , Female , Humans , Middle Aged
9.
J Assoc Res Otolaryngol ; 16(4): 413-32, 2015 Aug.
Article in English | MEDLINE | ID: mdl-25910607

ABSTRACT

The contribution of human ear canal orientation to tympanic membrane (TM) surface motion and sound pressure distribution near the TM surface is investigated by using an artificial ear canal (aEC) similar in dimensions to the natural human ear canal. The aEC replaced the bony ear canal of cadaveric human temporal bones. The radial orientation of the aEC relative to the manubrium of the TM was varied. Tones of 0.2 to 18.4 kHz delivered through the aEC induced surface motions of the TM that were quantified using stroboscopic holography; the distribution of sound in the plane of the tympanic ring P TR was measured with a probe tube microphone. The results suggest that the ear canal orientation has no substantial effect on TM surface motions, but P TR at frequencies above 10 kHz is influenced by the ear canal orientation. The complex TM surface motion patterns observed at frequencies above a few kilohertz are not correlated with simpler variations in P TR distribution at the same frequencies, suggesting that the complex sound-induced TM motions are more related to the TM mechanical properties, shape, and boundary conditions rather than to spatial variations in the acoustic stimulus.


Subject(s)
Ear Canal/physiology , Tympanic Membrane/physiology , Humans , Sound
10.
J Biomed Opt ; 20(5): 051028, 2015 May.
Article in English | MEDLINE | ID: mdl-25652791

ABSTRACT

The eardrum or tympanic membrane (TM) transforms acoustic energy at the ear canal into mechanical motions of the ossicles. The acousto-mechanical transformer behavior of the TM is determined by its shape, three-dimensional (3-D) motion, and mechanical properties. We have developed an optoelectronic holographic system to measure the shape and 3-D sound-induced displacements of the TM. The shape of the TM is measured with dual-wavelength holographic contouring using a tunable near IR laser source with a central wavelength of 780 nm. 3-D components of sound-induced displacements of the TM are measured with the method of multiple sensitivity vectors using stroboscopic holographic interferometry. To accurately obtain sensitivity vectors, a new technique is developed and used in which the sensitivity vectors are obtained from the images of a specular sphere that is being illuminated from different directions. Shape and 3-D acoustically induced displacement components of cadaveric human TMs at several excitation frequencies are measured at more than one million points on its surface. A numerical rotation matrix is used to rotate the original Euclidean coordinate of the measuring system in order to obtain in-plane and out-of-plane motion components. Results show that in-plane components of motion are much smaller (<20%) than the out-of-plane motions' components.


Subject(s)
Holography/methods , Imaging, Three-Dimensional/methods , Interferometry/methods , Stroboscopy/instrumentation , Stroboscopy/methods , Tympanic Membrane/physiology , Acoustics , Algorithms , Cadaver , Computers , Hearing , Humans , Light , Membranes, Artificial , Models, Theoretical , Motion , Reproducibility of Results , Sound , Vibration
11.
J Biomed Opt ; 19(9): 96001, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25191832

ABSTRACT

Understanding the human hearing process would be helped by quantification of the transient mechanical response of the human ear, including the human tympanic membrane (TM or eardrum). We propose a new hybrid high-speed holographic system (HHS) for acquisition and quantification of the full-field nanometer transient (i.e., >10 kHz) displacement of the human TM. We have optimized and implemented a 2 þ 1 frame local correlation (LC) based phase sampling method in combination with a high-speed (i.e., >40 K fps) camera acquisition system. To our knowledge, there is currently no existing system that provides such capabilities for the study of the human TM. The LC sampling method has a displacement difference of <11 nm relative to measurements obtained by a four-phase step algorithm. Comparisons between our high-speed acquisition system and a laser Doppler vibrometer indicate differences of <10 µs. The high temporal (i.e., >40 kHz) and spatial (i.e., >100 k data points) resolution of our HHS enables parallel measurements of all points on the surface of the TM, which allows quantification of spatially dependent motion parameters, such as modal frequencies and acoustic delays. Such capabilities could allow inferring local material properties across the surface of the TM.


Subject(s)
Holography/methods , Image Processing, Computer-Assisted/methods , Signal Processing, Computer-Assisted , Tympanic Membrane/physiology , Vibration , Algorithms , Female , Humans , Middle Aged , Reproducibility of Results
12.
SPIE Newsroom ; 2013 Jan 09.
Article in English | MEDLINE | ID: mdl-24375240

ABSTRACT

A novel system measures the structure, shape, and acoustically induced changes to the membrane of the human middle ear, to help diagnose and treat hearing disorders.

13.
J Acoust Soc Am ; 133(2): 918-37, 2013 Feb.
Article in English | MEDLINE | ID: mdl-23363110

ABSTRACT

Sound-induced motions of the surface of the tympanic membrane (TM) were measured using stroboscopic holography in cadaveric human temporal bones at frequencies between 0.2 and 18 kHz. The results are consistent with the combination of standing-wave-like modal motions and traveling-wave-like motions on the TM surface. The holographic techniques also quantified sound-induced displacements of the umbo of the malleus, as well as volume velocity of the TM. These measurements were combined with sound-pressure measurements near the TM to compute middle-ear input impedance and power reflectance at the TM. The results are generally consistent with other published data. A phenomenological model that behaved qualitatively like the data was used to quantify the relative magnitude and spatial frequencies of the modal and traveling-wave-like displacement components on the TM surface. This model suggests the modal magnitudes are generally larger than those of the putative traveling waves, and the computed wave speeds are much slower than wave speeds predicted by estimates of middle-ear delay. While the data are inconsistent with simple modal displacements of the TM, an alternate model based on the combination of modal motions in a lossy membrane can also explain these measurements without invoking traveling waves.


Subject(s)
Bone Conduction , Holography , Mechanotransduction, Cellular , Models, Biological , Tympanic Membrane/physiology , Acoustic Stimulation , Cadaver , Fourier Analysis , Humans , Motion , Pressure , Sound , Stroboscopy , Time Factors , Tympanic Membrane/anatomy & histology , Vibration
14.
Hear Res ; 301: 44-52, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23247058

ABSTRACT

UNLABELLED: Opto-electronic computer holographic measurements were made of the tympanic membrane (TM) in cadaveric chinchillas. Measurements with two laser wavelengths were used to compute the 3D-shape of the TM. Single laser wavelength measurements locked to eight distinct phases of a tonal stimulus were used to determine the magnitude and the relative phase of the surface displacements. These measurements were made at over 250,000 points on the TM surface. The measured motions contained spatial phase variations consistent with relatively low-order (large spatial frequency) modal motions and smaller magnitude higher-order (smaller spatial frequency) motions that appear to travel, but may also be explained by losses within the membrane. The measurement of shape and thin shell theory allowed us to separate the measured motions into those components orthogonal to the plane of the tympanic ring, and those components within the plane of the tympanic ring based on the 3D-shape. The predicted in-plane motion components are generally smaller than the out-of-plane perpendicular component of motion. Since the derivation of in-plane and out-of plane depended primarily on the membrane shape, the relative sizes of the predicted motion components did not vary with frequency. SUMMARY: A new method for simultaneously measuring the shape and sound-induced motion of the tympanic membrane is utilized to estimate the 3D motion on the membrane surface. This article is part of a special issue entitled "MEMRO 2012".


Subject(s)
Motion , Sound , Tympanic Membrane/anatomy & histology , Tympanic Membrane/physiology , Acoustic Stimulation , Animals , Chinchilla , Electronics , Equipment Design , Holography/methods , Lasers , Optics and Photonics , Vibration
15.
Opt Eng ; 52(10): 101916, 2013 Oct 01.
Article in English | MEDLINE | ID: mdl-24790255

ABSTRACT

Acoustically-induced vibrations of the Tympanic Membrane (TM) play a primary role in the hearing process, in that these motions are the initial mechanical response of the ear to airborne sound. Characterization of the shape and 3D displacement patterns of the TM is a crucial step to a better understanding of the complicated mechanics of sound reception by the ear. In this paper, shape and sound-induced 3D displacements of the TM in cadaveric chinchillas are measured by a lensless Dual-Wavelength Digital Holography system (DWDHS). The DWDHS consists of Laser Delivery (LD), Optical Head (OH), and Computing Platform (CP) subsystems. Shape measurements are performed in double-exposure mode and with the use of two wavelengths of a tunable laser while nanometer-scale displacements are measured along a single sensitivity direction and with a constant wavelength. In order to extract the three principal components of displacement in full-field-of-view, and taking into consideration the anatomical dimensions of the TM, we combine principles of thin-shell theory together with both, displacement measurements along the single sensitivity vector and TM surface shape. To computationally test this approach, Finite Element Methods (FEM) are applied to the study of artificial geometries.

16.
Proc IEEE Sens ; 2013: 1-4, 2013.
Article in English | MEDLINE | ID: mdl-25126153

ABSTRACT

Robot-assisted surgical procedures, taking advantage of the high soft tissue contrast and real-time imaging of magnetic resonance imaging (MRI), are developing rapidly. However, it is crucial to maintain tactile force feedback in MRI-guided needle-based procedures. This paper presents a Fabry-Perot interference (FPI) based system of an MRI-compatible fiber optic sensor which has been integrated into a piezoelectrically actuated robot for prostate cancer biopsy and brachytherapy in 3T MRI scanner. The opto-electronic sensing system design was minimized to fit inside an MRI-compatible robot controller enclosure. A flexure mechanism was designed that integrates the FPI sensor fiber for measuring needle insertion force, and finite element analysis was performed for optimizing the correct force-deformation relationship. The compact, low-cost FPI sensing system was integrated into the robot and calibration was conducted. The root mean square (RMS) error of the calibration among the range of 0-10 Newton was 0.318 Newton comparing to the theoretical model which has been proven sufficient for robot control and teleoperation.

17.
Scanning ; 33(5): 342-52, 2011.
Article in English | MEDLINE | ID: mdl-21898459

ABSTRACT

We describe a novel holographic otoscope system for measuring nanodisplacements of objects subjected to dynamic excitation. Such measurements are necessary to quantify the mechanical deformation of surfaces in mechanics, acoustics, electronics, biology, and many other fields. In particular, we are interested in measuring the sound-induced motion of biological samples, such as an eardrum. Our holographic otoscope system consists of laser illumination delivery (IS), optical head (OH), and image processing computer (IP) systems. The IS delivers the object beam (OB) and the reference beam (RB) to the OH. The backscattered light coming from the object illuminated by the OB interferes with the RB at the camera sensor plane to be digitally recorded as a hologram. The hologram is processed by the IP using the Fresnel numerical reconstruction algorithm, where the focal plane can be selected freely. Our holographic otoscope system is currently deployed in a clinic, and is packaged in a custom design. It is mounted in a mechatronic positioning system to increase its maneuverability degrees to be conveniently positioned in front of the object to be measured. We present representative results highlighting the versatility of our system to measure deformations of complex elastic surfaces in the wavelength scale including a copper foil membrane and postmortem tympanic membrane. SCANNING 33: 342-352, 2011. © 2011 Wiley Periodicals, Inc.


Subject(s)
Electronics, Medical/instrumentation , Holography/methods , Image Processing, Computer-Assisted/methods , Otoscopes/statistics & numerical data , Tympanic Membrane/physiology , Acoustics , Animals , Chinchilla , Electronics, Medical/methods , Equipment Design , Otolaryngology/methods , Sensitivity and Specificity , Vibration
18.
Otol Neurotol ; 32(9): 1559-67, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21956597

ABSTRACT

HYPOTHESIS: The sound-induced motion of the tympanic membrane has features that are most consistent with modal responses to a uniform stimulus. BACKGROUND: Conceptual models of the coupling of tympanic membrane motion to the ossicular chain can be classified as either modal responses to a uniform stimulation of the entire membrane or traveling wave models in which sound energy is captured at the membrane's rim and travels along the surface to the umbo. The stroboscopic holography technique we use can separate strongly modal or traveling wave-dominated motions of the tympanic membrane surface. METHODS: We use computer-aided optoelectronic holography with stroboscopic illumination to measure the magnitude and phase of the sound-induced motion of more than 40,000 points on the surface of the tympanic membrane in cadaveric human temporal bones. Our techniques are sensitive to motions of the membrane as small as 0.01 µm and allow determinations of membrane displacement at frequencies as large as 20 kHz. RESULTS: We report clear signs of both modal tympanic membrane responses and traveling waves on the human tympanic membrane. Modal responses are seen throughout the frequency range, whereas the traveling waves are most apparent between 2 and 8 kHz. In general, the magnitudes of the traveling waves are small compared with the modal magnitudes. CONCLUSION: Much of the motion of the tympanic membrane is well approximated by modal motions of the tympanic membrane surface. This conclusion has implications for eardrum pathology and its treatment.


Subject(s)
Models, Biological , Tympanic Membrane/physiology , Acoustic Stimulation , Holography , Humans , Sound , Stroboscopy , Vibration
19.
Hear Res ; 263(1-2): 78-84, 2010 May.
Article in English | MEDLINE | ID: mdl-19909803

ABSTRACT

Stroboscopic holography was used to quantify dynamic deformations of the tympanic membrane (TM) of the entire surface of the TM before and after cartilage tympanoplasty of the posterior or posterior-superior part of the TM. Cartilage is widely used in tympanoplasties to provide mechanical stability for the TM. Three human cadaveric temporal bones were used. A 6 mm x 3 mm oval cartilage graft was placed through the widely opened facial recess onto the medial surface of the posterior or posterior-superior part of the TM. The graft was either in contact with the bony tympanic rim and manubrium or not. Graft thickness was either 0.5 or 1.0mm. Stroboscopic holography produced displacement amplitude and phase maps of the TM surface in response to stimulus sound. Sound stimuli were 0.5, 1, 4 and 7 (or 8)kHz tones. Middle-ear impedance was measured from the motion of the entire TM. Cartilage placement generally produced reductions in the motion of the TM apposed to the cartilage, especially at 4 kHz and 7 or 8 kHz. Some parts of the TM showed altered motion compared to the control in all three cases. In general, middle-ear impedance was either unchanged or increased somewhat after cartilage reconstruction both at low (0.5 and 1 kHz) and high (4 and 7 kHz) frequencies. At 4 kHz, with the 1.0mm thick graft that was in contact with the bony tympanic rim, the impedance slightly decreased. While our earlier work with time-averaged holography allowed us to observe differences in the pattern of TM motion caused by application of cartilage to the TM, stroboscopic holography is more sensitive to TM motions and allowed us to quantify the magnitude and phase of motion of each point on the TM surface. Nonetheless, our results are similar to those of our earlier work: The placement of cartilage on the medial surface of TM reduces the motion of the TM that apposes the cartilage. These obvious local changes occur even though the cartilage had little effect on the sound-induced motion of the stapes.


Subject(s)
Cartilage/transplantation , Holography/methods , Stroboscopy/methods , Tympanic Membrane/physiology , Tympanic Membrane/surgery , Tympanoplasty/methods , Acoustic Impedance Tests , Acoustic Stimulation , Aged , Aged, 80 and over , Biomechanical Phenomena , Cadaver , Electric Impedance , Humans , In Vitro Techniques , Middle Aged , Movement/physiology , Vibration
20.
Hear Res ; 263(1-2): 66-77, 2010 May.
Article in English | MEDLINE | ID: mdl-20034549

ABSTRACT

Sound-induced motion of the surface of the human tympanic membrane (TM) was studied by stroboscopic holographic interferometery, which measures the amplitude and phase of the displacement at each of about 40,000 points on the surface of the TM. Measurements were made with tonal stimuli of 0.5, 1, 4 and 8 kHz. The magnitude and phase of the sinusoidal displacement of the TM at each driven frequency were derived from the fundamental Fourier component of the raw displacement data computed from stroboscopic holograms of the TM recorded at eight stimulus phases. The correlation between the Fourier estimates and measured motion data was generally above 0.9 over the entire TM surface. We used three data presentations: (i) plots of the phasic displacements along a single chord across the surface of the TM, (ii) phasic surface maps of the displacement of the entire TM surface, and (iii) plots of the Fourier derived amplitude and phase-angle of the surface displacement along four diameter lines that define and bisect each of the four quadrants of the TM. These displays led to some common conclusions: at 0.5 and 1kHz, the entire TM moved roughly in-phase with some small phase delay apparent between local areas of maximal displacement in the posterior half of the TM. At 4 and 8 kHz, the motion of the TM became more complicated with multiple local displacement maxima arranged in rings around the manubrium. The displacements at most of these maxima were roughly in-phase, while some moved out-of-phase. Superposed on this in- and out-of-phase behavior were significant cyclic variations in-phase with location of less than 0.2 cycles or occasionally rapid half-cycle step-like changes in-phase. The high frequency displacement amplitude and phase maps discovered in this study can not be explained by any single wave motion, but are consistent with a combination of low and higher order modal motions plus some small traveling-wave-like components. The observations of the dynamics of TM surface motion from this study will help us better understand the sound-receiving function of the TM and how it couples sound to the ossicular chain and inner ear.


Subject(s)
Holography/methods , Stroboscopy/methods , Tympanic Membrane/physiology , Acoustic Stimulation , Aged , Aged, 80 and over , Cadaver , Ear Ossicles/physiology , Female , Fourier Analysis , Holography/instrumentation , Holography/statistics & numerical data , Humans , In Vitro Techniques , Interferometry/instrumentation , Interferometry/methods , Interferometry/statistics & numerical data , Male , Middle Aged , Movement/physiology , Stroboscopy/instrumentation , Stroboscopy/statistics & numerical data , Vibration
SELECTION OF CITATIONS
SEARCH DETAIL
...