Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Oper Dent ; 49(2): 119-126, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38349853

ABSTRACT

When restoring anterior teeth using resin composites, the use of silicone guide matrices obtained from diagnostic wax-ups is recommended, as this technique facilitates layering and optimizes working time. This is particularly important in polychromatic layering and when more than one anterior tooth is to be restored with resin composites. However, in cases of fractured anterior teeth, it is often not feasible to perform a previous impression and waxing. In these cases, due to trauma and related psychological aspects, patients usually seek immediate esthetic solutions. Therefore, an interesting restorative approach that can simplify the restorative technique is the creation of a silicone guide matrix obtained from the patient's fractured tooth, without the need for prior waxing. This type of personalized matrix was initially proposed by Bertholdo, Ricci, and Barrote. Thus, the purpose of the present work is to demonstrate a modification of the technique for making this type of custom-made matrix for the restoration of two upper central incisors of a 14-year-old patient who fractured his teeth in a bicycle accident.


Subject(s)
Dental Restoration, Permanent , Tooth Fractures , Humans , Adolescent , Dental Restoration, Permanent/methods , Composite Resins/therapeutic use , Tooth Fractures/therapy , Incisor/injuries , Dental Care
2.
J Dent Res ; 101(6): 647-654, 2022 06.
Article in English | MEDLINE | ID: mdl-35001681

ABSTRACT

In this study, an acrylamide-based adhesive was combined with a thiourethane-based composite to improve bond stability and reduce polymerization stress, respectively, of simulated composite restorations. The stability testing was conducted under physiologic conditions, combining mechanical and bacterial challenges. Urethane dimethacrylate was combined with a newly synthesized triacrylamide (TMAAEA) or HEMA (2-hydroxyethyl-methacrylate; control) to produce a 2-step total-etch adhesive system. Methacrylate-based composites (70 wt% silanized filler) were formulated, containing thiourethane oligomers at 0 (control) or 20 wt%. Standardized preparations in human third molars were restored; then, epoxy replicas were obtained from the occlusal surfaces before and after 7-d storage in water or with Streptococcus mutans biofilm, which was tested after storage in an incubator (static) or the bioreactor (mechanical challenge). Images were obtained from the replicas (scanning electron microscopy) and cross sections of the samples (confocal laser scanning microscopy) and then analyzed to obtain measurements of gap, bacterial infiltration, and demineralization. Microtensile bond strength of specimens stored in water or biofilm was assessed in 1-mm2 stick specimens. Data were analyzed with analysis of variance and Tukey's test (α = 0.05). HEMA-based materials had greater initial gap measurements, indicating more efficient bonding for the acrylamide materials. When tested in water, the triacrylamide-based adhesive had smaller gaps in the incubator or bioreactor. In the presence of biofilm, there was less difference among materials, but the acrylamide/thiourethane combination led to statistically lower gap formation in the bioreactor. HEMA and TMAAEA-based adhesives produced statistically similar microtensile bond strengths after being stored in water for 7 d, but after the same period with biofilm-challenged specimens, the TMAAEA-based adhesives were the only ones to retain the initial bond strength values. The use of a stable multiacrylamide-based adhesive led to the preservation of the resin-dentin bonded interface after a physiologically relevant challenge. Future studies will include a multispecies biofilm model.


Subject(s)
Dental Bonding , Dentin-Bonding Agents , Acrylamides , Composite Resins/chemistry , Dental Cements/chemistry , Dentin , Dentin-Bonding Agents/chemistry , Humans , Materials Testing , Methacrylates/chemistry , Resin Cements/chemistry , Tensile Strength , Water
3.
Oper Dent ; 43(2): 113-120, 2018.
Article in English | MEDLINE | ID: mdl-29148913

ABSTRACT

The restoration of single discolored maxillary anterior teeth is still a difficult task, as not only shape and surface characterization play an important role in the success of the treatment, but the propagation of light throughout the restorative material does as well. In some cases, small changes in morphology, color, and brightness will be noticeable. These factors are sometimes very tricky, and shade guides alone are difficult to use for color selection. This article proposes a protocol of employing cross-polarization imaging for improving the accuracy of the shade selection of resin composites. The step-by-step technique is presented for the restoration of a single discolored tooth.


Subject(s)
Composite Resins/chemistry , Dental Restoration, Permanent , Photography/methods , Prosthesis Coloring , Tooth Discoloration/therapy , Adult , Esthetics, Dental , Female , Humans , Incisor , Maxilla , Tooth Bleaching
4.
Oper Dent ; 43(1): 31-37, 2018.
Article in English | MEDLINE | ID: mdl-29284097

ABSTRACT

The present in vivo randomized, triple-blinded, and split-mouth clinical study evaluated the effectiveness of a hybrid light (HL) source on the color change, stability, and tooth sensitivity in patients submitted to different in-office bleaching techniques. Twenty volunteers were divided into two groups and four subgroups. A split-mouth design was conducted to compare two in-office bleaching techniques (with and without light activation): 35% Lase Peroxide Sensy (LPS) + HL: 35% hydrogen peroxide (HP) + HL; 35% LPS: 35% HP; 25% LPS + HL: 25% HP + HL; and 35% Whiteness HP (WHP): 35% HP. For the groups activated with HL, the HP was applied on the enamel surface three consecutive times using a 3 × 2-minute protocol (three HL activations for two minutes each, with a 30-second interval for a total of seven minutes and 30 seconds) for each gel application, totaling 22 minutes and 30 seconds. For the other groups, HP was applied 3 × 15 minutes, totaling 45 minutes. A spectrophotometer was used to measure the color change (ΔE) before the treatment and 24 hours, one week, and one, 12, and 36 months after. A visual analog scale was used to evaluate the tooth sensitivity before the treatment, immediately following treatment, 24 hours, and one week after. Analysis of variance, Tukey's, Kruskall-Wallis, and Wilcoxon tests, all with α = 0.05 were performed. Statistical analysis did not reveal any significant differences (ΔE) between the in-office bleaching techniques with or without HL in the periods evaluated; the activation with HL required 50% less time to achieve such results. The groups without HL presented statistical differences for ΔE when comparing 24 hours with the other follow-up times (intergroup) and an increase in tooth sensitivity in the initial periods. All techniques and bleaching agents were effective on bleaching during a 36-month evaluation of color stability. The groups activated with HL presented lower sensitivity and required a lower activation time.


Subject(s)
Laser Therapy/methods , Tooth Bleaching/methods , Adolescent , Adult , Dentin Sensitivity , Double-Blind Method , Humans , Hydrogen Peroxide/administration & dosage , Hydrogen Peroxide/therapeutic use , Time Factors , Tooth Bleaching Agents/administration & dosage , Tooth Bleaching Agents/therapeutic use , Young Adult
5.
Oper Dent ; 42(3): 335-341, 2017.
Article in English | MEDLINE | ID: mdl-28467265

ABSTRACT

OBJECTIVE: The objective of this study was to evaluate the influence of adhesives with different 10-MDP concentrations on the shear bond strength of a resin cement to zirconia. METHODS AND MATERIALS: Six experimental adhesives were prepared with the following composition: camphorquinone, 1,2-diaminobenzene, butylhydroxytoluene, diphenyliodonium hexafluorophosphate, 2-hydroxyethyl methacrylate triethylene glycol dimethacrylate, ethoxylated bisphenol A glycol dimethacrylate, urethane dimethacrylate, bisphenol A diglycidyl methacrylate, and ethanol. The 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) monomer was added at 0wt%, 3wt%, 6wt%, 9wt%, 12wt%, or 15wt%. Three commercially available adhesives were evaluated: Single Bond Universal, Single Bond 2, and Signum Zirconia Bond. Resin cement cylinders made with RelyX Ultimate were bonded to yttria-stabilized tetragonal zirconia polycrystal with one of the evaluated adhesives and were subjected to the shear bond strength evaluation. Failure modes were analyzed with a stereoscopic loupe. Statistical analyses were performed with one-way analysis of variance and the Tukey's Honestly Significant Difference test (α=0.05). Pearson's was used to correlate the percentage of 10-MDP in the experimental adhesives and shear bond strength. RESULTS: There were significant differences between adhesives (p<0.00001). The highest shear bond strength values were obtained with the Signum Zirconia Bond and Single Bond Universal. Single Bond 2 showed the lowest values. There were no differences between experimental adhesives. All groups showed adhesives failures. A nonlinear correlation was found between bond strength and percentage of 10-MDP in experimental adhesives (r=0.872). CONCLUSIONS: The commercially available adhesives indicated for bonding to zirconia showed the highest bonding values.


Subject(s)
Dental Bonding/methods , Dental Cements/chemistry , Dental Materials/chemistry , Methacrylates/chemistry , Zirconium/chemistry , Bisphenol A-Glycidyl Methacrylate , Composite Resins , Dental Stress Analysis , Materials Testing , Shear Strength , Surface Properties
6.
Oper Dent ; 36(3): 274-80, 2011.
Article in English | MEDLINE | ID: mdl-21834710

ABSTRACT

OBJECTIVE: To evaluate, through the application of different dentin bonding systems, the influence of wetness on shear bond strength in enamel. METHODS: This study evaluated three etch-and-rinse adhesive systems (Scotchbond MP [used with and without primer]; Singlebond; and Prime&Bond 2.1) and two self-etching adhesive systems (Clearfil SE Bond; and Xeno IV). Flat bovine enamel surfaces were either air-dried for 30 seconds or blotted with absorbent paper after acid-etching for the conventional bonding agents or before the application of self-etching bonding agents. The resin composite EsthetX was bonded to flat surfaces that had been treated with one of the adhesives, following the manufacturer's instructions. After being stored in water at 37°C for one week, bonded specimens were broken in shear. Data were evaluated with two-way analysis of variance (ANOVA) and Student-Newman-Keuls tests (α=0.05). For comparing each condition individually, regardless of the adhesive or wetness condition, a one-way ANOVA and a Student-Newman-Keuls test (α=0.05) were applied. RESULTS: The two-way ANOVA showed significant differences among adhesive systems. An interaction effect was also observed (p<0.05), but wetness did not influence shear bond strength (p=0.98). The one-way ANOVA showed that the all-in-one adhesive was the only material influenced by the presence of water at the enamel's surface. CONCLUSION: The all-in-one adhesive behaved differently depending on whether the enamel surface was dry or wet.


Subject(s)
Dental Bonding , Dental Enamel/ultrastructure , Dentin-Bonding Agents/chemistry , Water/chemistry , Acetone/chemistry , Acid Etching, Dental/methods , Air , Animals , Bisphenol A-Glycidyl Methacrylate/chemistry , Cattle , Composite Resins/chemistry , Dental Materials/chemistry , Dental Stress Analysis/instrumentation , Desiccation , Materials Testing , Paper , Polymethacrylic Acids/chemistry , Resin Cements/chemistry , Shear Strength , Stress, Mechanical , Temperature , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...