Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Article in English | MEDLINE | ID: mdl-34711531

ABSTRACT

OBJECTIVE: as scarce literature on the topic is available, we aimed to compare diagnostic utility of semi-quantitative versus visual analysis in labelled white blood cell scintigraphy (WBCS) for osteoarticular infection. One-day and two-day protocols were assessed, particularly in orthopaedic devices. MATERIAL AND METHODS: prospective study of 79 consecutive patients with suspected osteoarticular infection. In all patients, WBCS were performed at 30min, 4h, 8h and 24h. Images were analysed by grouping in two protocols: one-day-protocol (experts evaluated 30min, 4h and 8h planar images) and two-day-protocol (experts evaluated 30min, 4h and 24h planar images). Planar images were interpreted qualitative and semiquantitatively and also were compared grouping patients with and without orthopaedic devices. To find which cut-off value of the percentage variation could predict of osteoarticular infection, multiple cut-off values were calculated in both protocols from the Youden index. Three blinded readers analysed the images. RESULTS: Comparing final diagnosis visual analysis of the one-day-protocol provided better results with sensitivity of 95.5%, specificity of 93% and diagnostic accuracy of 93.7% (p<001) than the two-day-protocol with values of 86.4%, 94.7% and 92.4%, respectively (p<001). For semi-quantitative analysis, the one-day-protocol also obtained better results with sensitivity of 72.7%, specificity of 78.9% and accuracy of 77.2% (p<001) than two-day-protocol (no significant results; p=0.14), especially in the group of patients with orthopaedic devices (sensitivity of 100%, specificity of 79.5% and accuracy of 82.7%; p<001). CONCLUSIONS: most accurate approach in the diagnosis of osteoarticular infection corresponded to visual analysis in one-day-protocol that showed greater sensitivity and specificity than semi-quantitative analysis. Semi-quantitative analysis only could be useful when visual analysis is doubtful. In patients with joint prostheses, an increase in percentage variation above 9% obtained maximum sensitivity and negative predictive value.


Subject(s)
Leukocytes , Humans , Predictive Value of Tests , Prospective Studies , Sensitivity and Specificity
3.
Sci Rep ; 9(1): 10640, 2019 07 23.
Article in English | MEDLINE | ID: mdl-31337779

ABSTRACT

The present work investigates the influence of different biological and physical parameters on image quality (IQ) perception of the abdominal area in a modern PET scanner, using new reconstruction algorithms and testing the utility of a radiomics approach. Scans of 112 patients were retrospectively included. Images were reconstructed using both OSEM + PSF and BSRM methods, and IQ of the abdominal region was subjectively evaluated. First, 22 IQ related parameters were obtained (including count rate and biological or mixed parameters) and compared to the subjective IQ scores by means of correlations and logistic regression. Second, an additional set of radiomics features was extracted, and a model was constructed by means of an elastic-net regression. For the OSEM + PSF and especially for the BSRM reconstructions, IQ parameters presented only at best moderated correlations with the subjective IQ. None of the studied parameters presented a good predictive power for IQ, while a simple radiomics model increased the performance of the IQ prediction. These results suggest the necessity of changing the standard parameters to evaluate IQ, particularly when a BSRM algorithm is involved. Furthermore, it seems that a simple radiomics model can outperform the use of any single parameter to assess IQ.


Subject(s)
Abdomen/diagnostic imaging , Neoplasms/diagnostic imaging , Positron-Emission Tomography/methods , Adult , Aged , Aged, 80 and over , Algorithms , Female , Fluorodeoxyglucose F18/administration & dosage , Humans , Image Processing, Computer-Assisted/methods , Male , Middle Aged , Retrospective Studies , Young Adult
4.
Clin Nucl Med ; 44(3): 194-200, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30562193

ABSTRACT

OBJECTIVE: Medullary thyroid carcinoma (MTC) is a rare malignancy. Location of residual, recurrent, or metastatic disease is crucial to treatment management and outcome. We aimed to evaluate the use of F-FDG PET/CT in localizing MTC foci in patients with biochemical relapse. METHODS: This is a retrospective cohort study. Review of 51 FDG PET/CT studies of 45 patients referred to restage MTC due to increased calcitonin (Ctn) and carcinoembryonic antigen (CEA) values at follow-up. FDG PET/CT diagnostic accuracy was determined through a patient-based analysis, using histology as criterion standard when available, or other imaging studies and clinical follow-up otherwise (mean, 4 years). RESULTS: There were 25 positive scans. Sensitivity, specificity, positive and negative predictive values, diagnostic accuracy, and positive likelihood ratio were 66.7%, 83.3%, 88.0%, 57.7%, 72.5%, and 4.0, respectively. Using a Ctn cutoff of 1000 pg/mL, sensitivity increased to 76.9%. There were significant differences of Ctn and CEA values between positive and negative FDG PET/CT (P < 0.05). Regarding true-positive studies, average SUVmax comparing locoregional and metastatic disease was at the limit of significance (P = 0.046). CONCLUSIONS: PET/CT can be useful to restage patients with biochemical relapse of MTC, with a better performance in higher Ctn levels. Its high positive predictive value (88%) may impact in the therapeutic management, although its low negative predictive value (57.7%) makes strict follow-up mandatory in examinations without pathologic findings.


Subject(s)
Carcinoma, Neuroendocrine/diagnostic imaging , Carcinoma, Neuroendocrine/pathology , Fluorodeoxyglucose F18 , Positron Emission Tomography Computed Tomography , Thyroid Neoplasms/diagnostic imaging , Thyroid Neoplasms/pathology , Adult , Aged , Aged, 80 and over , Calcitonin/metabolism , Carcinoembryonic Antigen/metabolism , Carcinoma, Neuroendocrine/metabolism , Female , Humans , Male , Middle Aged , Neoplasm Metastasis , Neoplasm, Residual , Recurrence , Retrospective Studies , Sensitivity and Specificity , Thyroid Neoplasms/metabolism , Young Adult
5.
Med Phys ; 45(7): 3214-3222, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29782657

ABSTRACT

INTRODUCTION: The aim of this study was to evaluate the behavior of a penalized-likelihood image reconstruction method (Q.Clear) under different count statistics and lesion-to-background ratios (LBR) on a BGO scanner, in order to obtain an optimum penalization factor (ß value) to study and optimize for different acquisition protocols and clinical goals. METHODS: Both phantom and patient images were evaluated. Data from an image quality phantom were acquired using different Lesion-to-Background ratios and acquisition times. Then, each series of the phantom was reconstructed using ß values between 50 and 500, at intervals of 50. Hot and cold contrasts were obtained, as well as background variability and contrast-to-noise ratio (CNR). Fifteen 18 F-FDG patients (five brain scans and 10 torso acquisitions) were acquired and reconstructed using the same ß values as in the phantom reconstructions. From each lesion in the torso acquisition, noise, contrast, and signal-to-noise ratio (SNR) were computed. Image quality was assessed by two different nuclear medicine physicians. Additionally, the behaviors of 12 different textural indices were studied over 20 different lesions. RESULTS: Q.Clear quantification and optimization in patient studies depends on the activity concentration as well as on the lesion size. In the studied range, an increase on ß is translated in a decrease in lesion contrast and noise. The net product is an overall increase in the SNR, presenting a tendency to a steady value similar to the CNR in phantom data. As the activity concentration or the sphere size increase the optimal ß increases, similar results are obtained from clinical data. From the subjective quality assessment, the optimal ß value for torso scans is in a range between 300 and 400, and from 100 to 200 for brain scans. For the recommended torso ß values, texture indices present coefficients of variation below 10%. CONCLUSIONS: Our phantom and patients demonstrate that improvement of CNR and SNR of Q.Clear algorithm which depends on the studied conditions and the penalization factor. Using the Q.Clear reconstruction algorithm in a BGO scanner, a ß value of 350 and 200 appears to be the optimal value for 18F-FDG oncology and brain PET/CT, respectively.


Subject(s)
Image Processing, Computer-Assisted , Phantoms, Imaging , Positron Emission Tomography Computed Tomography/instrumentation , Brain/diagnostic imaging , Humans , Likelihood Functions , Signal-To-Noise Ratio , Torso/diagnostic imaging
6.
J Nucl Med ; 58(7): 1155-1161, 2017 07.
Article in English | MEDLINE | ID: mdl-28302761

ABSTRACT

The aim of this study was to assess the physical performance of a new PET/CT system, the Discovery IQ with 5-ring detector blocks. Methods: Performance was measured using the National Electrical Manufacturers Association NU2-2012 methodology. Image quality was extended by accounting for different acquisition parameters (lesion-to-background ratios [8:1, 4:1, and 2:1] and acquisition times) and reconstruction algorithms (VUE-point HD [VPHD], VPHD with point-spread-function modeling [VPHD-S], and Q.Clear). Tomographic reconstruction was also assessed using a Jaszczak phantom. Additionally, 30 patient lesions were analyzed to account for differences in lesion volume and SUV quantification between reconstruction algorithms. Results: Spatial resolution ranged from 4.2 mm at 1 cm to 8.5 mm at 20 cm. Sensitivity measured at the center and at 10 cm was 22.8 and 20.4 kps/kBq, respectively. The noise-equivalent counting rate peak was 124 kcps at 9.1 kBq/cm3 The scatter fraction was 36.2%. The accuracy of correction for count losses and randoms was 3.9%. In the image quality test, contrast recovery for VPHD, VPHD-S, and Q.Clear ranged from 18%, 18%, and 13%, respectively (hot contrast; 10-mm sphere diameter; ratio, 2:1), to 68%, 67%, and 81%, respectively (cold contrast; 37-mm sphere diameter; ratio, 8:1). Background variability ranged from 3.4%, 3.0%, and 2.1%, respectively (ratio, 2:1), to 5.5%, 4.8%, and 3.7%, respectively (ratio, 8:1). On Q.Clear reconstruction, the decrease in the penalty term (ß) increased the contrast recovery coefficients and background variability. With the Jaszczak phantom, image quality increased overall when a reconstruction algorithm modeling the point-spread function was used, and use of Q.Clear increased the signal-to-noise ratio. Lesions analyzed using VPHD-S and Q.Clear had an SUVmean of 6.5 ± 3 and 7 ± 3, respectively (P < 0.01), and an SUVmax of 11 ± 4.8 and 12 ± 4, respectively (P < 0.01). No significant difference in mean lesion volume was found between algorithms. Conclusion: Among the various Discovery bismuth germanium oxide-based PET/CT scanners, the IQ with 5-ring detector blocks has the highest overall performance, with improved sensitivity and counting rate performance. Q.Clear reconstruction improves the PET image quality, with higher recovery coefficients and lower background variability.


Subject(s)
Neoplasms/diagnostic imaging , Positron Emission Tomography Computed Tomography/instrumentation , Whole Body Imaging/instrumentation , Equipment Design , Equipment Failure Analysis , Humans , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity , Signal-To-Noise Ratio
7.
Article in English | MEDLINE | ID: mdl-27559300

ABSTRACT

Computed tomography (CT) has been used as the reference imaging technique for the initial staging of diffuse large B-cell lymphoma until recent days, when the introduction of positron emission tomography (PET)/CT imaging as a hybrid technique has become of routine use. However, the performance of both examinations is still common. The aim of this work was to compare the findings between low-dose 2-deoxy-2-((18)F)fluoro-d-glucose ((18)F-FDG) PET/CT and full-dose contrast-enhanced CT (ceCT) in 28 patients with localized diffuse large B-cell lymphoma according to PET/CT findings, in order to avoid the performance of ceCT. For each technique, a comparison in the number of nodal and extranodal involved regions was performed. PET/CT showed more lesions than ceCT in both nodal (41 vs. 36) and extranodal localizations (16 vs. 15). Disease staging according to both techniques was concordant in 22 patients (79%) and discordant in 6 patients (21%), changing treatment management in 3 patients (11%). PET/CT determined a better staging and therapeutic approach, making the performance of an additional ceCT unnecessary.

10.
PET Clin ; 9(2): 117-27, 2014 Apr.
Article in English | MEDLINE | ID: mdl-25030277

ABSTRACT

There is a growing interest in using quantification in FDG-PET/CT in oncology, especially for evaluating response to therapy. Complex full quantitative procedures with blood sampling and dynamic scanning have been clinically replaced by the use of standardized uptake value measurements that provide an index of regional tracer uptake normalized to the administered dose of FDG. Some approaches have been proposed for assessing quantitative metabolic response, such as EORTC and PERCIST criteria in solid tumors. When using standardized uptake value in clinical routine and multicenter trials, standardization of protocols and quality control procedures of instrumentation is required.


Subject(s)
Fluorodeoxyglucose F18 , Multimodal Imaging/standards , Neoplasms/diagnostic imaging , Positron-Emission Tomography/standards , Radiopharmaceuticals , Tomography, X-Ray Computed/standards , Calibration , Equipment Failure , Humans , Medical Errors , Multimodal Imaging/methods , Neoplasm Staging , Neoplasms/pathology , Positron-Emission Tomography/instrumentation , Positron-Emission Tomography/methods , Quality Control , Radiometry , Tomography, X-Ray Computed/methods , Treatment Outcome
11.
Clin Nucl Med ; 39(1): e46-52, 2014 Jan.
Article in English | MEDLINE | ID: mdl-23640215

ABSTRACT

PURPOSE: The evaluation of bone marrow infiltration (BMI) is of crucial importance in the staging of lymphoma. Although bone marrow biopsy (BMB) is the reference standard for the evaluation of BMI, it has limitations. PET/CT has become an excellent tool in staging of lymphoma, and bone marrow uptake is correlated with the involvement of lymphoma. The aim of this study was to assess the utility of PET/CT and its concordance with BMB in the detection of BMI in patients with diffuse large B-cell lymphoma (DLBCL) and Hodgkin lymphoma (HL). PATIENTS AND METHODS: One hundred forty-seven patients with DLBCL (84) and HL (63) were referred for a PET/CT and a BMB (unilateral) at the initial staging. The reference standard was BMB. RESULTS: Bone marrow infiltration was detected by PET/CT in 39 (26%) and by BMB in 21 (14%) cases. There was concordance between PET/CT and BMB in 128 patients (87%) (74 DLBCL, 54 HL), 21 with positive PET/CT and BMB results and 107 with negative PET/CT and BMB results. Discordant results were observed in 19 patients (14%); 18 of them with positive PET/CT and negative standard BMB results (not performed in active sites). The sensitivity, specificity, accuracy, as well as positive and negative predictive values of FDG-PET/CT for the detection of BMI were 95%, 86%, 87%, 54%, and 99%, respectively. CONCLUSIONS: PET/CT detects more bone marrow involvement in DLBCL and HL compared with BMB. Its good concordance with BMB makes it a complementary technique, as it helps select the biopsy site in cases with negative results.


Subject(s)
Bone Marrow/pathology , Fluorodeoxyglucose F18 , Lymphoma, Large B-Cell, Diffuse/pathology , Multimodal Imaging , Neoplasm Staging/methods , Positron-Emission Tomography , Tomography, X-Ray Computed , Adolescent , Adult , Aged , Female , Humans , Lymphoma, Large B-Cell, Diffuse/diagnostic imaging , Male , Middle Aged , Young Adult
12.
Am J Med ; 123(6): 558-62, 2010 Jun.
Article in English | MEDLINE | ID: mdl-20569766

ABSTRACT

OBJECTIVE: To determine the value of whole-body [(18)F] fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) for diagnosing occult malignant disease in patients with myositis compared with broad conventional cancer screening. METHODS: We prospectively studied 55 consecutive patients with a recent diagnosis of myositis in 3 teaching hospitals over a 3-year period by whole-body FDG-PET/CT and compared the results with those of conventional cancer screening, which included thoracoabdominal CT, mammography, gynecologic examination, ultrasonography, and tumor marker analysis. Comparisons were made using predictive values and their 95% confidence intervals. RESULTS: A total of 9 of 55 patients were diagnosed with paraneoplastic myositis. FDG uptake was positive in 7 patients (1 false-positive), negative in 44 patients (3 false-negative), and inconclusive in 4 patients. Positive and negative predictive values of FDG-PET/CT for the diagnosis of cancer were 85.7% and 93.8%, respectively. Conventional screening was cancer-positive in 9 patients (2 false-positive) and negative in the remaining 46 patients (2 false-negative). Positive and negative predictive values were 77.8% and 95.7%, respectively. The overall predictive value of broad conventional screening was the same as that of FDG-PET/CT (92.7 vs 92.7). CONCLUSION: The performance of FDG-PET/CT, a single imaging study, for diagnosing occult malignant disease in patients with myositis was comparable to that of broad conventional screening, which includes multiple tests.


Subject(s)
Dermatomyositis/diagnosis , Mass Screening/methods , Paraneoplastic Syndromes/diagnosis , Polymyositis/diagnosis , Aged , Dermatomyositis/complications , Dermatomyositis/epidemiology , Diagnosis, Differential , Female , Follow-Up Studies , Humans , Incidence , Male , Mammography , Middle Aged , Paraneoplastic Syndromes/complications , Paraneoplastic Syndromes/epidemiology , Polymyositis/complications , Polymyositis/epidemiology , Positron-Emission Tomography , Predictive Value of Tests , Prospective Studies , Spain/epidemiology , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...