Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Adv Lab Med ; 3(1): 51-66, 2022 Mar.
Article in English, Spanish | MEDLINE | ID: mdl-37359435

ABSTRACT

Objectives: We evaluated the prevalence of 25-hydroxyvitamin D (25-(OH)D) deficiency in our setting according to season, sex, and age. We also studied the association with parathyroid hormone (PTH) levels. Methods: The study population comprised all patients with requests for assessment of 25-(OH)D between January 1 and December 31, 2018, as registered in the database of the laboratory information system. Major exclusion criteria were pediatric samples (<18 years) and factors affecting 25-(OH)D and/or PTH levels (i.e., kidney injury, liver disease, PTH disorders). Results: Among 33,601 patients (24,028 women, 9,573 men), the prevalence of 25-(OH)D deficiency was 48%. Prevalence was greater in males than in females (53% vs. 46%). By age group, deficiency was more prevalent in quartile 1 (Q1, 74-87 years) and less prevalent in quartile 2 (Q2, 60-73 years). By season, deficiency was greater in spring (nonsignificant differences with respect to winter) and lower in summer. The association between 25-(OH)D and PTH was assessed in 9,368 persons. Linear regression analysis showed a weak association (coefficient - 0.303). Multiple logistic regression analysis revealed a significant association between 25-(OH)D deficiency and increased PTH (Odds ratio (OR), 1.63). Other risk factors for increased PTH include female sex (OR, 1.27), season (winter, OR 1.63, spring OR 1.16), and age (quartile 1, OR, 3). Conclusions: The prevalence of 25-(OH)D deficiency differed according to sex, age, and season of the year. Furthermore, elevation of PTH is mainly influenced by low 25-(OH)D, female sex, season, and age.

2.
J Emerg Nurs ; 40(1): 20-6, 2014 Jan.
Article in English | MEDLINE | ID: mdl-22766144

ABSTRACT

INTRODUCTION: Our aim was to evaluate the equivalence between analytic parameters from blood samples obtained from a saline solution lock device used for the infusion of drugs and those from venipuncture. In our emergency department, patients bearing a saline solution lock device have blood extracted by venipuncture to avoid possible contamination of the sample. METHODS: Adults from the emergency department with a saline solution lock device who required laboratory tests were selected as candidates for this cross-sectional observational study. Infusions were halted and flushed with 0.9% saline solution; 2 minutes later, 2 mL of blood was drawn and discarded, and the corresponding laboratory tubes were filled. Immediately after, another sample was withdrawn from the opposite extremity by venipuncture. Both samples were analyzed for hematology, biochemistry, venous blood gases, and coagulation parameters. Concordance was evaluated by use of the intraclass correlation coefficient with its 95% confidence intervals; Bland-Altman plots were used to illustrate the percentage of samples with differences exceeding 2 SDs. The mean differences were also checked to detect those exceeding the laboratory's systematic error. RESULTS: An intraclass correlation coefficient of over 0.9 was achieved for all parameters except for pH, partial pressure of carbon dioxide, and partial pressure of oxygen. Differences of over 2 SDs were found in fewer than 10% of all parameters. None of them exceeded 3 SDs, except for pH and venous blood gases. All parameters showed differences below the laboratory's accepted systematic error except for pH and venous blood gases. DISCUSSION: Blood samples extracted from a peripheral catheter with or without drug infusions are valid for the analysis of hematology, biochemistry, and coagulation parameters but not for venous blood gases. Nurses should know the benefits of using an existing peripheral catheter for drawing blood samples for laboratory analysis even when infusing commonly used drugs. Emergency nurses should consider collecting blood specimens from a venous access device regardless of the type of drug infusions administered, because it is a safe, simple, and fast technique, which is time efficient when treating patients with limited venous access sites. This procedure reduces patient discomfort and the risk of complications related to venipunctures.


Subject(s)
Catheterization, Peripheral/methods , Catheters, Indwelling/statistics & numerical data , Emergency Nursing/methods , Phlebotomy/methods , Adult , Catheterization, Peripheral/statistics & numerical data , Cross-Sectional Studies , Female , Humans , Male , Phlebotomy/statistics & numerical data , Prospective Studies , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...