Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Front Cardiovasc Med ; 8: 678812, 2021.
Article in English | MEDLINE | ID: mdl-34336946

ABSTRACT

Objectives: Coronary sinus (CS) based mitral annuloplasty using the Carillon device is a therapeutic option for the treatment of functional mitral valve regurgitation (FMR). Background: Little is known about the change of CS and mitral valve annulus (MVA) planes following Carillon implantation and how they are modulated by the tension applied on the device. Methods: In a retrospective single-center analysis, 10 patients underwent Carillon device implantation and received CT-angiography (CTA) prior and post CS based percutaneous mitral valve repair. Patients were assigned to responders or non-responders according to the 3-month transthoracic echocardiographic follow-up. A prototype software was used to assess distance and angulation of both CS (pre) or Carillon-device (post) and mitral annulus planes. Results: Comparison of the distance and angulation of the CS plane or Carillon device plane and the MVA plane prior and post intervention showed significant reduction of distance and unchanged angulation in responders while angulation was increased and distance reduced in non-responders without statistical significance. Furthermore, in FMR responders MVA perimeter, anterior-posterior diameter, intercommisural diameter and MVA area were decreased following successful indirect mitral valve annuloplasty, while in FMR non-responders Carillon device implantation had no effect on MVA geometry. Conclusions: Insufficient reduction of FMR following indirect mitral valve annuloplasty is associated with device malposition in relation to the mitral valve annulus. Patient selection using CTA-derived distance and angulation of CS to MVA planes is one option to increase effectiveness of indirect mitral valve annuloplasty.

2.
Catheter Cardiovasc Interv ; 98(7): 1393-1401, 2021 12 01.
Article in English | MEDLINE | ID: mdl-34169643

ABSTRACT

OBJECTIVES: Coronary sinus (CS) based mitral annuloplasty using the Carillon device could be limited by compromise of the left circumflex artery (Cx). BACKGROUND: Computed tomography (CT) might be a feasible tool for preprocedural planning of indirect mitral valve annuloplasty. METHODS: In a retrospective analysis, 25 patients underwent Carillon device implantation and received CT-angiography (CTA) analysis prior to CS based percutaneous mitral valve repair. We used a retrospective approach with preprocedural CTA and intraprocedural coronary sinus angiography (CSA) measurements to determine the CS to Cx distance at the occlusion or compression point or in the distal landing zone in absence of Cx compromise. RESULTS: According to left coronary artery angiography, we identified 7 patients with Cx occlusion, 7 with Cx compression and 11 without Cx compromise. No difference in minimal CS to Cx distance between the three groups could be obtained. Also, neither distal CS diameter nor distal Carillon anchor size were related to Cx impingement. However, ROC analysis identified a CS to Cx distance of <8.6 mm specifically in the distal device landing zone to predict Cx compromise. Furthermore, CTA was accurate in assessing device length in comparison to CSA, but failed predicting Carillon device anchor size. CONCLUSIONS: CTA derived CS to Cx distance in the device landing zone might be helpful to predict Cx occlusion during Carillon device implantation. Furthermore, CTA predicted CS length but not anchor size correctly. Therefore, CT-angiographic procedural planning might help improving the results of percutaneous CS-based mitral valve repair.


Subject(s)
Mitral Valve Annuloplasty , Mitral Valve Insufficiency , Coronary Angiography , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Annuloplasty/adverse effects , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Retrospective Studies , Tomography, X-Ray Computed , Treatment Outcome
3.
Open Heart ; 8(1)2021 05.
Article in English | MEDLINE | ID: mdl-34006505

ABSTRACT

OBJECTIVES: The presence of coronary artery disease (CAD) in patients hospitalised with paroxysmal or first diagnosed atrial fibrillation (AF) has major implications for antithrombotic therapy and cardiovascular event rate. Coronary CT angiography (CCTA) is a feasible tool to identify patients with concealed CAD. We aimed to evaluate the diagnostic role of early CCTA in patients hospitalised with paroxysmal or first diagnosed AF. METHODS: In a 5-year single-centre retrospective analysis, 566 patients with paroxysmal or first diagnosed AF who underwent CCTA were enrolled to investigate the presence of CAD. RESULTS: In patients with paroxysmal or first diagnosed AF, CCTA revealed CAD (coronary artery stenosis ≥50%) in 39.2%. Cardiac catheterisation was performed in 31.6%, confirming CAD in 13.1% of all patients. In 8.0% percutaneous coronary intervention and in 0.5% coronary artery bypass grafting was performed. In patients with paroxysmal or first diagnosed AF: (1) angina pectoris per se does not predict CAD; (2) multivariable regression analysis revealed age, male sex and diabetes as risk factors for CAD in AF; (3) Framingham Risk Score for coronary heart disease and CHA2DS2-VASc-Score were relevant risk scores of CAD and (4) the classification of Coronary Artery Calcium score reference values according to the Multi-Ethnic Study of Atherosclerosis was a predictor of CAD. CONCLUSION: Patients with paroxysmal or first diagnosed AF are at risk for CAD, while CCTA is a feasible diagnostic tool for CAD. We recommend to integrate CT calcium scoring and CCTA into the diagnostic workup of patients with new-onset or paroxysmal AF.


Subject(s)
Atrial Fibrillation/diagnosis , Computed Tomography Angiography/methods , Coronary Angiography/methods , Coronary Artery Disease/diagnosis , Risk Assessment/methods , Tachycardia, Paroxysmal/diagnosis , Aged , Atrial Fibrillation/complications , Coronary Artery Disease/complications , Feasibility Studies , Female , Follow-Up Studies , Humans , Male , Retrospective Studies , Risk Factors
5.
Catheter Cardiovasc Interv ; 97(3): 495-502, 2021 02 15.
Article in English | MEDLINE | ID: mdl-32602976

ABSTRACT

OBJECTIVES: Coronary sinus (CS) based mitral annuloplasty using the Carillon device is effective in reducing functional mitral valve regurgitation (FMR). However, this positive effect might be dependent on the relation between CS and the mitral annulus. BACKGROUND: Computed tomography (CT) assessment prior to mitral valve interventions is an emerging technique to optimize patient selection. METHODS: In a retrospective analysis 30 patients underwent Carillon device implantation and received CT-angiography prior to CS based percutaneous mitral valve repair. Patients were assigned to responders or non-responders according to the 3-month transthoracic echocardiographic follow-up including quantitative mitral valve regurgitation assessment. A prototype software for CS reconstruction was used to assess distance and angle of both CS and mitral annulus planes. RESULTS: Comparison of the distance and angle of the CS plane and the mitral valve annulus plane showed a significant shorter distance and lower angle in the responder group implicating an impact on procedure success. Our results suggest a CS plane and MV annulus plane with a favorably distance of <7.8 mm and an optimal angle of <14.2° could be considered favorably for mitral annuloplasty using a Carillon device. CONCLUSIONS: Distance and angle of mitral annulus and CS planes determined by three-dimensional reconstructions of CT-angiography might predict a reduction in echocardiographic FMR using Carillon Mitral Contour System.


Subject(s)
Mitral Valve Annuloplasty , Mitral Valve Insufficiency , Coronary Angiography , Humans , Mitral Valve Annuloplasty/adverse effects , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Retrospective Studies , Tomography, X-Ray Computed , Treatment Outcome
8.
Clin Cardiol ; 41(12): 1528, 2018 12.
Article in English | MEDLINE | ID: mdl-30259541

Subject(s)
Thrombocytopenia , Humans
9.
Clin Cardiol ; 41(12): 1521-1526, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30144122

ABSTRACT

BACKGROUND: Little is known about heparin-induced thrombocytopenia (HIT), a pro-thrombotic, potentially life-threatening immune-mediated reaction to heparin exposure, in conservative and interventional cardiovascular medicine. HYPOTHESIS: The 4T score, validated for prediction of HIT in surgical patients before, is also suitable for assessing HIT probability in cardiovascular patients with unclear thrombocytopenia. METHODS: A total of 403 consecutive patients from our Department of Cardiology, Angiology and Pneumology in whom a HIT screening test was performed between 2009 and 2016 were identified. All 72 patients with a positive screening test were subjected to a functional confirmation test (heparin-induced platelet activation test, HIPA), resulting in 23 patients with serologically confirmed HIT (positive screening test, positive HIPA) and 49 patients with nonconfirmed HIT (positive screening test, negative HIPA). RESULTS: The 4TScore had a sensitivity of 82.6% and a specificity of 28.6% in our patients, suggesting that it might not sufficiently predict the clinical probability of HIT in cardiovascular patients. In both confirmed and nonconfirmed HIT, intrahospital mortality was high without a significant difference (30% in confirmed HIT vs 43% in nonconfirmed HIT). Bacteremia was more often found in patients with nonconfirmed HIT, suggesting infection as a frequent differential diagnosis of thrombocytopenia in these patients (49% vs 17%, P = 0.0185). CONCLUSION: HIT screening should be initiated in cardiovascular patients with unclear thrombocytopenia despite a low 4Tscore in order to distinguish patients requiring alternative anticoagulants from those with other causes such as infections. Further research is needed to specify the risk profile for HIT in cardiovascular patients.


Subject(s)
Cardiovascular Diseases/complications , Heparin/adverse effects , Inpatients , Thrombocytopenia/chemically induced , Aged , Anticoagulants/adverse effects , Cardiovascular Diseases/diagnosis , Cardiovascular Diseases/mortality , Female , Follow-Up Studies , Germany/epidemiology , Hospital Mortality/trends , Humans , Male , Middle Aged , Prognosis , Reproducibility of Results , Retrospective Studies , Survival Rate/trends , Thrombocytopenia/complications , Thrombocytopenia/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL
...