1.
PLoS One ; 15(11): e0233586, 2020.
Article in English | MEDLINE | ID: mdl-33232326

ABSTRACT

BACKGROUND: Three-dimensional (3D) scanning is an established method of breast volume estimation. However, this method can never be entirely precise, since the thoracic wall cannot be imaged by the surface scanner. Current methods rely on interpolation of the posterior breast border from the surrounding thoracic wall. Here, we present a novel method to calculate the posterior border and increase the accuracy of the measurement. METHODS: Using principal component analysis, computed tomography images were used to build a statistical shape model (SSM) of the thoracic wall. The model was fitted to 3D images and the missing thoracic wall curvature interpolated (indirect volumetry). The calculations were evaluated by ordinary least squares regression between the preoperative and postoperative volume differences and the resection weights in breast reduction surgery (N = 36). Also, an SSM of the breast was developed, allowing direct volumetry. Magnetic-resonance images (MRI) and 3D scans were acquired from 5 patients in order to validate the direct 3D volumetry. RESULTS: Volumetry based on a SSM exhibited a higher determination coefficient (R2 = 0,737) than the interpolation method (R2 = 0,404). The methods were not equivalent (p = 0.75), suggesting that the methods significantly differ. There was no influence of BMI on the correlation in either method. The MRI volumetry had a strong correlation with the 3D volumetry (R2 = 0,978). CONCLUSION: The SSM-based method of posterior breast border calculation is reliable and superior to the currently used method of interpolation. It should serve as a basis of software applications aiming at calculation of breast volume from 3D surface scanning data.


Subject(s)
Breast/diagnostic imaging , Breast/surgery , Imaging, Three-Dimensional/methods , Adult , Cytoreduction Surgical Procedures , Female , Humans , Magnetic Resonance Imaging , Middle Aged , Models, Statistical , Principal Component Analysis
3.
PLoS One ; 10(10): e0139763, 2015.
Article in English | MEDLINE | ID: mdl-26496192

ABSTRACT

INTRODUCTION: Recent advances have enabled fast magnetic resonance imaging (MRI) of solid materials. This development has opened up new applications for MRI, but, at the same time, uncovered new challenges. Previously, MRI-invisible materials like the housing of MRI detection coils are now readily depicted and either cause artifacts or lead to a decreased image resolution. In this contribution, we present versatile, multi-nuclear single and dual-tune MRI coils that stand out by (1) a low hydrogen content for high-resolution MRI of dry solids without artifacts; (2) a modular approach with exchangeable inductors of variable volumes to optimally enclose the given object; (3) low cost and low manufacturing effort that is associated with the modular approach; (4) accurate sample placement in the coil outside of the bore, and (5) a wide, single- or dual-tune frequency range that covers several nuclei and enables multinuclear MRI without moving the sample. MATERIALS AND METHODS: The inductors of the coils were constructed from self-supporting copper sheets to avoid all plastic materials within or around the resonator. The components that were mounted at a distance from the inductor, including the circuit board, coaxial cable and holder were manufactured from polytetrafluoroethylene. RESULTS AND CONCLUSION: Residual hydrogen signal was sufficiently well suppressed to allow 1H-MRI of dry solids with a minimum field of view that was smaller than the sensitive volume of the coil. The SNR was found to be comparable but somewhat lower with respect to commercial, proton-rich quadrature coils, and higher with respect to a linearly-polarized commercial coil. The potential of the setup presented was exemplified by 1H/23Na high-resolution zero echo time (ZTE) MRI of a model solution and a dried human molar at 9.4 T. A full 3D image dataset of the tooth was obtained, rich in contrast and similar to the resolution of standard cone-beam computed tomography.


Subject(s)
Hydrogen/chemistry , Magnetic Resonance Imaging/instrumentation , Animals , Calibration , Electricity , Houseflies , Imaging, Three-Dimensional , Signal Processing, Computer-Assisted , Signal-To-Noise Ratio , Time Factors