Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
Add more filters










Publication year range
1.
ACS Appl Nano Mater ; 7(5): 5598-5609, 2024 Mar 08.
Article in English | MEDLINE | ID: mdl-38481750

ABSTRACT

Au trisoctahedrons (TOHs) with sharp tips and high-index facets have exceptional properties for diverse applications, such as plasmon-enhanced spectroscopies, catalysis, sensing, and biomedicine. However, the synthesis of Au TOHs remains challenging, and most reported synthetic methods are time-consuming or involve complex steps, hindering the exploration of their potential applications. Herein, we present a facile and fast approach to prepare Au TOHs with high uniformity and good control over the final size and shape, all within less than 10 min of synthesis, for surface-enhanced Raman spectroscopy (SERS) and refractive index sensing. The size of the Au TOHs can be easily tailored over a wide range, from 39 to 268 nm, allowing a tuning of the plasmon resonance at wavelengths from visible to near-infrared regions. The exposed facets of the Au TOHs can also be varied by controlling the growth temperatures. The wide tunability of size and exposed facets of Au TOHs can greatly broaden the range of their applications. We have also encapsulated Au TOHs with zeolite imidazolate framework (ZIF-8), obtaining core-shell hybrid structures. With the ability to tune Au TOH size, we further assessed their SERS performances in function of their size by detecting 2-NaT in solution, exhibiting enhancement factors of the order of 105 with higher values when the LSPR is blue-shifted from the laser excitation wavelength. Au TOHs have been also compared for refractive index sensing applications against Au nanospheres, revealing Au TOHs as better candidates. Overall, this facile and fast method for synthesizing Au TOHs with tunable size and exposed facets simplifies the path toward the exploration of properties and applications of this highly symmetrical and high-index nanostructure.

2.
Acc Chem Res ; 49(9): 2041-8, 2016 09 20.
Article in English | MEDLINE | ID: mdl-27501067

ABSTRACT

Carbon materials have a long history of use as electrodes in electrochemistry, from (bio)electroanalysis to applications in energy technologies, such as batteries and fuel cells. With the advent of new forms of nanocarbon, particularly, carbon nanotubes and graphene, carbon electrode materials have taken on even greater significance for electrochemical studies, both in their own right and as components and supports in an array of functional composites. With the increasing prominence of carbon nanomaterials in electrochemistry comes a need to critically evaluate the experimental framework from which a microscopic understanding of electrochemical processes is best developed. This Account advocates the use of emerging electrochemical imaging techniques and confined electrochemical cell formats that have considerable potential to reveal major new perspectives on the intrinsic electrochemical activity of carbon materials, with unprecedented detail and spatial resolution. These techniques allow particular features on a surface to be targeted and models of structure-activity to be developed and tested on a wide range of length scales and time scales. When high resolution electrochemical imaging data are combined with information from other microscopy and spectroscopy techniques applied to the same area of an electrode surface, in a correlative-electrochemical microscopy approach, highly resolved and unambiguous pictures of electrode activity are revealed that provide new views of the electrochemical properties of carbon materials. With a focus on major sp(2) carbon materials, graphite, graphene, and single walled carbon nanotubes (SWNTs), this Account summarizes recent advances that have changed understanding of interfacial electrochemistry at carbon electrodes including: (i) Unequivocal evidence for the high activity of the basal surface of highly oriented pyrolytic graphite (HOPG), which is at least as active as noble metal electrodes (e.g., platinum) for outer-sphere redox processes. (ii) Demonstration of the high activity of basal plane HOPG toward other reactions, with no requirement for catalysis by step edges or defects, as exemplified by studies of proton-coupled electron transfer, redox transformations of adsorbed molecules, surface functionalization via diazonium electrochemistry, and metal electrodeposition. (iii) Rationalization of the complex interplay of different factors that determine electrochemistry at graphene, including the source (mechanical exfoliation from graphite vs chemical vapor deposition), number of graphene layers, edges, electronic structure, redox couple, and electrode history effects. (iv) New methodologies that allow nanoscale electrochemistry of 1D materials (SWNTs) to be related to their electronic characteristics (metallic vs semiconductor SWNTs), size, and quality, with high resolution imaging revealing the high activity of SWNT sidewalls and the importance of defects for some electrocatalytic reactions (e.g., the oxygen reduction reaction). The experimental approaches highlighted for carbon electrodes are generally applicable to other electrode materials and set a new framework and course for the study of electrochemical and interfacial processes.

3.
ACS Appl Mater Interfaces ; 8(12): 8008-16, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26953499

ABSTRACT

A new method for transferring chemical vapor deposition (CVD)-grown monolayer graphene to a variety of substrates is described. The method makes use of an organic/aqueous biphasic configuration, avoiding the use of any polymeric materials that can cause severe contamination problems. The graphene-coated copper foil sample (on which graphene was grown) sits at the interface between hexane and an aqueous etching solution of ammonium persulfate to remove the copper. With the aid of an Si/SiO2 substrate, the graphene layer is then transferred to a second hexane/water interface to remove etching products. From this new location, CVD graphene is readily transferred to arbitrary substrates, including three-dimensional architectures as represented by atomic force microscopy (AFM) tips and transmission electron microscopy (TEM) grids. Graphene produces a conformal layer on AFM tips, to the very end, allowing easy production of tips for conductive AFM imaging. Graphene transferred to copper TEM grids provides large-area, highly electron-transparent substrates for TEM imaging. These substrates can also be used as working electrodes for electrochemistry and high-resolution wetting studies. By using scanning electrochemical cell microscopy, it is possible to make electrochemical and wetting measurements at either a freestanding graphene film or a copper-supported graphene area and readily determine any differences in behavior.

4.
Phys Chem Chem Phys ; 17(17): 11827-38, 2015 May 07.
Article in English | MEDLINE | ID: mdl-25869656

ABSTRACT

The electron transfer (ET) kinetics of three redox couples in aqueous solution, IrCl6(2-/3-), Ru(NH3)6(3+/2+) and Fe(CN)6(4-/3-), on different grades of highly oriented pyrolytic graphite (HOPG) have been investigated in a droplet-cell setup. This simple configuration allows measurements to be made on a very short time scale after cleavage of HOPG, so as to minimise possible effects from (atmospheric) contamination, and with minimal, if any, change to the HOPG surface. However, the droplet-cell geometry differs from more conventional electrochemical setups and is more prone to ohmic drop effects. The magnitude of ohmic drop is elucidated by modelling the electric field in a typical droplet configuration. These simulations enable ohmic effects to be minimised practically by optimising the positions of the counter and reference electrodes in the droplet, and by using a concentration ratio of electrolyte to redox species that is higher than used conventionally. It is shown that the ET kinetics for all of the redox species studied herein is fast on all grades of HOPG and lower limits for ET rate constants are deduced. For IrCl6(2-/3-) and Fe(CN)6(4-/3-), ET on HOPG is at least as fast as on Pt electrodes, and for Ru(NH3)6(3+/2+) ET kinetics on HOPG is comparable to Pt electrodes. Given the considerable difference in the density of electronic states (DOS) between graphite and metal electrodes, the results tend to suggest that the DOS of the electrode does not play an important role in the ET kinetics of these outer-sphere redox couples over the range of values encompassing HOPG and metals. This can be rationalised because the DOS of all of these different electrode materials is orders of magnitude larger than those of the redox species in solution, so that with strong electronic coupling between the redox couple and electrode (adiabatic electron transfer) the electronic structure of the electrode becomes a relatively unimportant factor in the ET kinetics.

5.
ACS Nano ; 9(4): 3558-71, 2015 Apr 28.
Article in English | MEDLINE | ID: mdl-25758160

ABSTRACT

The electrochemical (EC) behavior of mechanically exfoliated graphene and highly oriented pyrolytic graphite (HOPG) is studied at high spatial resolution in aqueous solutions using Ru(NH3)6(3+/2+) as a redox probe whose standard potential sits close to the intrinsic Fermi level of graphene and graphite. When scanning electrochemical cell microscopy (SECCM) data are coupled with that from complementary techniques (AFM, micro-Raman) applied to the same sample area, different time-dependent EC activity between the basal planes and step edges is revealed. In contrast, other redox couples (ferrocene derivatives) whose potential is further removed from the intrinsic Fermi level of graphene and graphite show uniform and high activity (close to diffusion-control). Macroscopic voltammetric measurements in different environments reveal that the time-dependent behavior after HOPG cleavage, peculiar to Ru(NH3)6(3+/2+), is not associated particularly with any surface contaminants but is reasonably attributed to the spontaneous delamination of the HOPG with time to create partially coupled graphene layers, further supported by conductive AFM measurements. This process has a major impact on the density of states of graphene and graphite edges, particularly at the intrinsic Fermi level to which Ru(NH3)6(3+/2+) is most sensitive. Through the use of an improved voltammetric mode of SECCM, we produce movies of potential-resolved and spatially resolved HOPG activity, revealing how enhanced activity at step edges is a subtle effect for Ru(NH3)6(3+/2+). These latter studies allow us to propose a microscopic model to interpret the EC response of graphene (basal plane and edges) and aged HOPG considering the nontrivial electronic band structure.

6.
Anal Chem ; 87(7): 3566-73, 2015 Apr 07.
Article in English | MEDLINE | ID: mdl-25719392

ABSTRACT

The fabrication and use of a multifunctional electrochemical probe incorporating two independent carbon working electrodes and two electrolyte-filled barrels, equipped with quasi-reference counter electrodes (QRCEs), in the end of a tapered micrometer-scale pipet is described. This "quad-probe" (4-channel probe) was fabricated by depositing carbon pyrolytically into two diagonally opposite barrels of a laser-pulled quartz quadruple-barrelled pipet. After filling the open channels with electrolyte solution, a meniscus forms at the end of the probe and covers the two working electrodes. The two carbon electrodes can be used to drive local electrochemical reactions within the meniscus while a bias between the QRCEs in the electrolyte channels provides an ion conductance signal that is used to control and position the meniscus on a surface of interest. When brought into contact with a surface, localized high resolution amperometric imaging can be achieved with the two carbon working electrodes with a spatial resolution defined by the meniscus contact area. The substrate can be an insulating material or (semi)conductor, but herein, we focus mainly on conducting substrates that can be connected as a third working electrode. Studies using both aqueous and ionic liquid electrolytes in the probe, together with gold and individual single walled carbon nanotube samples, demonstrate the utility of the technique. Substrate generation-dual tip collection measurements are shown to be characterized by high collection efficiencies (approaching 100%). This hybrid configuration of scanning electrochemical microscopy (SECM) and scanning electrochemical cell microscopy (SECCM) should be powerful for future applications in electrode mapping, as well as in studies of insulating materials as demonstrated by transient spot redox-titration measurements at an electrostatically charged Teflon surface and at a pristine calcite surface, where a functionalized probe is used to follow the immediate pH change due to dissolution.


Subject(s)
Electrochemical Techniques/instrumentation , Ions/chemistry , Microscopy/instrumentation , Electrodes , Electrolytes/chemistry , Equipment Design , Gold/chemistry , Hydrogen-Ion Concentration , Ionic Liquids/chemistry , Nanotubes, Carbon/ultrastructure
9.
Faraday Discuss ; 172: 439-55, 2014.
Article in English | MEDLINE | ID: mdl-25427004

ABSTRACT

The electrochemical (EC) oxidation of the neurotransmitter, serotonin, at individual single-walled carbon nanotubes (SWNTs) is investigated at high resolution using a novel platform that combines flow-aligned SWNTs with atomic force microscopy, Raman microscopy, electronic conductance measurements, individual SWNT electrochemistry and high-resolution scanning electrochemical cell microscopy (SECCM). SECCM has been used to visualise the EC activity along side-wall sections of metallic SWNTs to assess the extent to which side-walls promote the electrochemistry of this complex multi-step process. Uniform and high EC activity is observed that is consistent with significant reaction at the side-wall, rather than electrochemistry being driven by defects alone. By scanning forward and reverse (trace and retrace) over the same region of a SWNT, it is also possible to assess any blocking of EC activity by serotonin oxidation reaction products. At a physiologically relevant concentration (5 µM), there is no detectable blocking of SWNTs, which can be attributed, at least in part, to the high diffusion rate to an individual, isolated SWNT in the SECCM format. At higher serotonin concentration (2 mM), oligomer formation from oxidation products is much more significant and major blocking of the EC process is observed from line profiles recorded as the SECCM meniscus moves over an SWNT. The SECCM line profile morphology is shown to be highly diagnostic of whether blocking occurs during EC processes. The studies herein add to a growing body of evidence that various EC processes at SWNTs, from simple outer sphere redox reactions to complex multi-step processes, occur readily at pristine SWNTs. The platform described is of general applicability to various types of nanostructures and nanowires.


Subject(s)
Nanotubes, Carbon/chemistry , Serotonin/chemistry , Electrochemical Techniques , Microscopy/methods , Oxidation-Reduction
10.
J Am Chem Soc ; 136(32): 11252-5, 2014 Aug 13.
Article in English | MEDLINE | ID: mdl-25061694

ABSTRACT

There is a prevailing and widely adopted view that carbon nanotubes, which are finding considerable application in energy, healthcare, and electronics applications, are highly (electro)catalytically inert unless modified, doped, or defected. By visualizing the electrochemical reduction of oxygen (hydrogen peroxide generation) at high resolution along pristine (defect-free) regions of individual single-walled carbon nanotubes, we show that there is, in fact, significant activity comparable to that of standard gold electrocatalysts. Moreover, the activity is greatly enhanced at strained (kinked) sites and regions modified by oxidation. Single-walled carbon nanotubes are thus effective electrocatalysts in their own right and not just supports for other materials.

11.
Nano Lett ; 14(1): 220-4, 2014 Jan 08.
Article in English | MEDLINE | ID: mdl-24274402

ABSTRACT

We introduce a multiprobe platform for the investigation of single-walled carbon nanotubes (SWNTs) that allows the electrochemical response of an individual SWNT to be mapped at high spatial resolution and correlated directly with the intrinsic electronic and structural properties. With this approach, we develop a detailed picture of the factors controlling electrochemistry at SWNTs and propose a definitive model that has major implications for future architectures of SWNT electrode devices.


Subject(s)
Conductometry/methods , Materials Testing/methods , Microelectrodes , Microscopy, Scanning Probe/methods , Nanotechnology/instrumentation , Nanotubes, Carbon/chemistry , Electric Conductivity , Equipment Design , Equipment Failure Analysis , Nanotechnology/methods
12.
J Am Chem Soc ; 136(1): 36-9, 2014 Jan 08.
Article in English | MEDLINE | ID: mdl-24325138

ABSTRACT

Interest in the controlled chemical functionalization of sp(2) carbon materials using diazonium compounds has been recently reignited, particularly as a means to generate a band gap in graphene. We demonstrate local diazonium modification of pristine sp(2) carbon surfaces, with high control, at the micrometer scale through the use of scanning electrochemical cell microscopy (SECCM). Electrochemically driven diazonium patterning is investigated at a range of driving forces, coupled with surface analysis using atomic force microscopy (AFM) and Raman spectroscopy. We highlight how the film density, level of sp(2)/sp(3) rehybridization and the extent of multilayer formation can be controlled, paving the way for the use of localized electrochemistry as a route to controlled diazonium modification.

13.
Chem Commun (Camb) ; 49(50): 5657-9, 2013 Jun 25.
Article in English | MEDLINE | ID: mdl-23680678

ABSTRACT

Boron doped diamond (BDD) disk ultramicroelectrodes have been used to sense single nanoparticle (NP) electrocatalytic collision events. BDD serves as an excellent support electrode due to its electrocatalytic inactivity and low background currents and thus can be used to detect the electroactivity of a wide range of colliding NPs, with high sensitivity. In particular, single NP collisions for hydrazine oxidation at Au and Pt NPs were shown to be markedly different.

14.
Article in English | MEDLINE | ID: mdl-23560932

ABSTRACT

Scanning electrochemical cell microscopy (SECCM) is a new pipette-based imaging technique purposely designed to allow simultaneous electrochemical, conductance, and topographical visualization of surfaces and interfaces. SECCM uses a tiny meniscus or droplet, at the end of a double-barreled (theta) pipette, for high-resolution functional imaging and nanoscale electrochemical measurements. Here we introduce this technique and provide an overview of its principles, instrumentation, and theory. We discuss the power of SECCM in resolving complex structure-activity problems and provide considerable new information on electrode processes by referring to key example systems, including graphene, graphite, carbon nanotubes, nanoparticles, and conducting diamond. The many longstanding questions that SECCM has been able to answer during its short existence demonstrate its potential to become a major technique in electrochemistry and interfacial science.

15.
Chem Commun (Camb) ; 48(60): 7435-7, 2012 Aug 04.
Article in English | MEDLINE | ID: mdl-22614748

ABSTRACT

The electrochemical properties of the closed ends and sidewalls of pristine carbon nanotube forests are investigated directly using a nanopipet electrochemical cell. Both are shown to promote fast electron transfer, without any activation or processing of the carbon nanotube material required, in contrast to the current model in the literature.

16.
Proc Natl Acad Sci U S A ; 109(29): 11487-92, 2012 Jul 17.
Article in English | MEDLINE | ID: mdl-22635266

ABSTRACT

Carbon nanotubes have attracted considerable interest for electrochemical, electrocatalytic, and sensing applications, yet there remains uncertainty concerning the intrinsic electrochemical (EC) activity. In this study, we use scanning electrochemical cell microscopy (SECCM) to determine local heterogeneous electron transfer (HET) kinetics in a random 2D network of single-walled carbon nanotubes (SWNTs) on an Si/SiO(2) substrate. The high spatial resolution of SECCM, which employs a mobile nanoscale EC cell as a probe for imaging, enables us to sample the responses of individual portions of a wide range of SWNTs within this complex arrangement. Using two redox processes, the oxidation of ferrocenylmethyl trimethylammonium and the reduction of ruthenium (III) hexaamine, we have obtained conclusive evidence for the high intrinsic EC activity of the sidewalls of the large majority of SWNTs in networks. Moreover, we show that the ends of SWNTs and the points where two SWNTs cross do not show appreciably different HET kinetics relative to the sidewall. Using finite element method modeling, we deduce standard rate constants for the two redox couples and demonstrate that HET based solely on characteristic defects in the SWNT side wall is highly unlikely. This is further confirmed by the analysis of individual line profiles taken as the SECCM probe scans over an SWNT. More generally, the studies herein demonstrate SECCM to be a powerful and versatile method for activity mapping of complex electrode materials under conditions of high mass transport, where kinetic assignments can be made with confidence.


Subject(s)
Electrochemical Techniques/methods , Nanotubes, Carbon/chemistry , Computer Simulation , Electrochemistry , Electrodes , Electron Transport/physiology , Finite Element Analysis , Microscopy/methods , Oxidation-Reduction , Silicon Dioxide/chemistry
17.
J Am Chem Soc ; 134(17): 7258-61, 2012 May 02.
Article in English | MEDLINE | ID: mdl-22486239

ABSTRACT

As a new form of carbon, graphene is attracting intense interest as an electrode material with widespread applications. In the present study, the heterogeneous electron transfer (ET) activity of graphene is investigated using scanning electrochemical cell microscopy (SECCM), which allows electrochemical currents to be mapped at high spatial resolution across a surface for correlation with the corresponding structure and properties of the graphene surface. We establish that the rate of heterogeneous ET at graphene increases systematically with the number of graphene layers, and show that the stacking in multilayers also has a subtle influence on ET kinetics.

18.
Anal Chem ; 84(5): 2483-91, 2012 Mar 06.
Article in English | MEDLINE | ID: mdl-22279955

ABSTRACT

Scanning electrochemical cell microscopy (SECCM) is a high resolution electrochemical scanning probe technique that employs a dual-barrel theta pipet probe containing electrolyte solution and quasi-reference counter electrodes (QRCE) in each barrel. A thin layer of electrolyte protruding from the tip of the pipet ensures that a gentle meniscus contact is made with a substrate surface, which defines the active surface area of an electrochemical cell. The substrate can be an electrical conductor, semiconductor, or insulator. The main focus here is on the general case where the substrate is a working electrode, and both ion-conductance measurements between the QRCEs in the two barrels and voltammetric/amperometric measurements at the substrate can be made simultaneously. In usual practice, a small perpendicular oscillation of the probe with respect to the substrate is employed, so that an alternating conductance current (ac) develops, due to the change in the dimensions of the electrolyte contact (and hence resistance), as well as the direct conductance current (dc). It is shown that the dc current can be predicted for a fixed probe by solving the Nernst-Planck equation and that the ac response can also be derived from this response. Both responses are shown to agree well with experiment. It is found that the pipet geometry plays an important role in controlling the dc conductance current and that this is easily measured by microscopy. A key feature of SECCM is that mass transport to the substrate surface is by diffusion and, for charged analytes, ion migration which can be controlled and varied quantifiably via the bias between the two QRCEs. For a working electrode substrate this means that charged redox-active analytes can be transported to the electrode/solution interface in a well-defined and controllable manner and that relatively fast heterogeneous electron transfer kinetics can be studied. The factors controlling the voltammetric response are determined by both simulation and experiment. Experiments demonstrate the realization of simultaneous quantitative voltammetric and ion conductance measurements and also identify a general rule of thumb that the surface contacted by electrolyte is of the order of the pipet probe dimensions.


Subject(s)
Electrochemical Techniques , Ions/chemistry , Microscopy , Models, Theoretical , Electric Conductivity , Electrodes , Electrolytes/chemistry , Electron Transport
19.
Phys Chem Chem Phys ; 12(34): 10108-14, 2010 Sep 14.
Article in English | MEDLINE | ID: mdl-20689900

ABSTRACT

The characteristics of three different carbon electrodes, glassy carbon (GC), oxygen-terminated polycrystalline boron-doped diamond (pBDD) and "pristine" carbon nanotube networks (CNTN) as voltammetric sensors for detection of the neurotransmitter serotonin have been investigated. For each electrode, detection sensitivity was determined using cyclic voltammetry (CV), a technique often used to provide information on chemical identity in electrochemical assays. The CNTN electrodes were found to exhibit background current densities ca. two orders of magnitude smaller than the GC electrode and ca. twenty times smaller than pBDD, as a consequence of their "pristine" low capacitance and low surface coverage. This was a major factor in determining serotonin detection limits from CV, of 10 nM for the CNTN electrode, 500 nM for pBDD and 2 microM for GC. The two most sensitive electrodes (CNTN and pBDD) were further investigated in terms of resistance to electrode fouling. CV analysis showed that fouling was less on the pBDD electrode compared to the CNTN and, furthermore, for the case of pBDD could be significantly minimised by careful selection of the CV potential limits, in particular by scanning the electrode potential to suitably cathodic values after oxidation of the serotonin.


Subject(s)
Boron/chemistry , Diamond/chemistry , Electrochemistry/methods , Glass/chemistry , Nanotubes, Carbon/chemistry , Serotonin/analysis , Catalysis , Electric Conductivity , Electrodes , Limit of Detection , Oxidation-Reduction , Serotonin/chemistry , Volatilization , Water/chemistry
20.
Nano Lett ; 8(9): 3017-22, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18712931

ABSTRACT

The resistance, R, of single gold nanowires was measured in situ during electrooxidation in aqueous 0.10 M sulfuric acid. Electrooxidation caused the formation of a gold oxide that is approximately 0.8 monolayers (ML) in thickness at +1.1 V vs saturated mercurous sulfate reference electrode (MSE) based upon coulometry and ex situ X-ray photoelectron spectroscopic analysis. As the gold nanowires were electrooxidized, R increased by an amount that depended on the wire thickness, ranging from Delta R/ R 0.10V = 14% for a 63 nm (h) x 200 nm (w) wire to 57% for an 18 nm (h) x 95 nm (w) wire at +1.1 V. These nanowires were millimeters in total length, but just 46 microm lengths were exposed to the electrolyte solution. The oxidation process and the accompanying increase in R were reversible: Reduction of the oxide at +0.10 V resulted in recovery of the reduced wire R except for a small resistance offset caused by the dissolution of approximately 0.4 ML of gold during each oxidation/reduction cycle. The measured increase in R during oxidation exceeds by a factor of 4 the predicted increases in R associated with the reduction in cross-sectional area of the nanowire and the expected decrease in the specular scattering parameter, p, at the gold-oxide interface at wire surfaces. We propose that this anomalous increase in R is caused by infiltration of the oxide into the nanowire at grain boundaries.

SELECTION OF CITATIONS
SEARCH DETAIL
...