Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
Add more filters










Publication year range
1.
BMC Oral Health ; 24(1): 619, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38807138

ABSTRACT

PURPOSE: The aim of this in vitro study was to evaluate the changes the rheological properties of some soft lining materials, to compare the rheological properties and viscoelastic behaviour at different temperatures. MATERIALS AND METHODS: Five soft lining materials (acrylic and silicone based) were used. the storage modulus (G'), loss modulus (G"), tan delta (tan δ) and complex viscosity (η') were chosen and for each material, measurements were repeated at 23, 33 and 37  °C, using an oscillating rheometer. All data were statistically analyzed using the Mann Whitney U test, Kruskal Wallis test and Conover's Multiple Comparison test at the significance level of 0.05. RESULTS: Soft lining materials had different viscoelastic properties and most of the materials showed different rheological behavior at 23, 33 and 37  °C. At the end of the test (t¹5), at all the temperatures, Sofreliner Tough M had the highest storage modulus values while Visco Gel had the highest loss Tan delta values. CONCLUSIONS: There were significant changes in the rheological parameters of all the materials. Also temperature affected the initial rheological properties, and polymerization reaction of all the materials, depending on temperature increase. CLINICAL IMPLICATIONS: Temperature affected the initial rheological properties, and polymerization reaction of soft denture liner materials, and clinical inferences should be drawn from such studies conducted. It can be recommended to utilize viscoelastic acrylic-based temporary soft lining materials with lower storage modulus, higher tan delta value, and high viscosity in situations where pain complaint persists and tissue stress is extremely significant, provided that they are replaced often.


Subject(s)
Acrylic Resins , Materials Testing , Rheology , Temperature , Viscosity , Acrylic Resins/chemistry , Elasticity , Denture Liners , Elastic Modulus , Dental Cavity Lining , Silicones/chemistry , Polymerization , Humans , Oscillometry
2.
Biomed Tech (Berl) ; 67(5): 419-428, 2022 Oct 26.
Article in English | MEDLINE | ID: mdl-35972416

ABSTRACT

This study's purpose is to assess the stress distribution in the peri-implant bone, implants, and prosthetic framework using two different posterior implant angles. All-on-four maxillary prostheses fabricated from feldspathic-ceramic-veneered zirconia-reinforced lithium silicate (ZLS) and feldspathic-ceramic-veneered cobalt-chromium (CoCr) were designed with 17 or 30-degree-angled posterior implants. Posterior cantilever and frontal vertical loads were applied to all models. The distribution of maximum and minimum principal stresses (σmax and σmin) and von Mises stress (σVM) was evaluated. Under posterior cantilever load, with an increase in posterior implant angle, σmax decreased by 4 and 7 MPa in the cortical bone when ZLS and CoCr were used as a prosthetic framework, respectively. Regardless of the framework material, 17-degree-angled posterior implants showed the highest σVM (541.36 MPa under posterior cantilever load; 110.79 MPa under frontal vertical load) values. Regardless of the posterior implant angle, ZLS framework showed the highest σVM (91.59 MPa under posterior cantilever load; 218.99 MPa under frontal vertical load) values. Increasing implant angle from 17 to 30° caused a decrease in σmax values in the cortical bone. Designs with 30-degree posterior implant angles and ZLS framework material may be preferred in All-on-four implant-supported fixed complete dentures.


Subject(s)
Dental Implants , Dental Prosthesis , Ceramics , Dental Prosthesis Design , Dental Prosthesis, Implant-Supported , Dental Stress Analysis , Finite Element Analysis , Maxilla/surgery , Stress, Mechanical
3.
Biomed Tech (Berl) ; 67(4): 307-315, 2022 Aug 26.
Article in English | MEDLINE | ID: mdl-35587648

ABSTRACT

The study aimed to evaluate the biomechanical behaviors of different prosthetic materials and posterior implant angles in All-on-4 implant-supported fixed maxillary prostheses with three-dimensional (3D) finite element analysis. The model of complete edentulous maxilla was created using the Rhinoceros and VRMesh Studio programs. Anterior vertical and 17°- and 30°-angled posterior implants were positioned with All-on-4 design. Straigth and angled multi-unit abutments scanned using a 3D scanner. Two different prosthetic superstructures (monolithic zirconia framework and lithium disilicate veneer (ZL) and monolithic zirconia-reinforced lithium silicate (ZLS)) were modeled. Four models designed according to the prosthetic structure and posterior implant angles. Posterior vertical bilateral loading and frontal oblique loading was performed. The principal stresses (bone tissues-Pmax and Pmin) and von Mises equivalent stresses (implant and prosthetic structures) were analyzed. In all models, the highest Pmax stress values were calculated under posterior bilateral loading in cortical bone. The highest von Mises stress levels occured in the posterior implants under posterior bilateral load (260.33 and 219.50 MPa) in the ZL-17 and ZL-30 models, respectively. Under both loads, higher stress levels in prosthetic structures were shown in the ZLS models compared with ZL models. There was no difference between posterior implant angles on stress distribution occurred in implant material and alveolar bone tissue. ZLS and ZL prosthetic structures can be reliably used in maxillary All-on-4 rehabilitation.


Subject(s)
Dental Implants , Maxilla , Biomechanical Phenomena , Dental Prosthesis, Implant-Supported , Dental Stress Analysis , Finite Element Analysis , Maxilla/surgery , Prostheses and Implants , Stress, Mechanical
4.
Int J Comput Dent ; 21(4): 335-344, 2018.
Article in English | MEDLINE | ID: mdl-30539176

ABSTRACT

This clinical report describes a digital workflow using an intraoral digital impression and cone beam computed tomography (CBCT) volumetric data to create a three-dimensional (3D) virtual model of the dentition, defect area, and soft and hard tissue of a patient who had undergone a hemimaxillectomy. Stereolithography (SLA) 3D printing technology was used to produce a resin mold, from which an obturator prosthesis was fabricated through a conventional technique.


Subject(s)
Cone-Beam Computed Tomography , Dental Impression Technique , Dental Prosthesis Design , Palatal Obturators , Printing, Three-Dimensional , Computer-Aided Design , Female , Humans , Imaging, Three-Dimensional , Jaw, Edentulous, Partially/therapy , Maxilla/surgery , Middle Aged
5.
J Oral Implantol ; 40(1): 76-83, 2014 Feb.
Article in English | MEDLINE | ID: mdl-22150347

ABSTRACT

The present study compared the use of cone beam computerized tomography (CBCT) images and intra-oral radiographs in the placement of final implant drills in terms of nerve damage to cadaver mandibles. Twelve cadaver hemimandibles obtained from 6 cadavers were used. Right hemimandibles were imaged using peri-apical radiography and left hemimandibles using CBCT, and the images obtained were used in treatment planning for the placement of implant drills (22 for each modality, for a total of 44 final drills). Specimens were dissected, and the distances between the apex of the final implant drill and the inferior alveolar neurovascular bundle and incisive nerve were measured using a digital calliper. Nerves were assessed as damaged or not damaged, and the Chi-square test was used to compare nerve damage between modalities (P < 0.05). Nerve damage occurred with 7 final drills placed based on peri-apical radiography (31.8%) and 1 final drill placed using CBCT images (4.5%). The difference in nerve damage between imaging modalities was statistically significant (P = 0.023), with CBCT outperforming intraoral film in the placement of final implant drills ex vivo. In order to prevent nerve damage, CBCT is recommended as the principal imaging modality for pre-implant assessment.


Subject(s)
Dental Implantation, Endosseous/adverse effects , Mandible/surgery , Mandibular Nerve/diagnostic imaging , Trigeminal Nerve Injuries/etiology , Cadaver , Cone-Beam Computed Tomography/methods , Dental Implantation, Endosseous/instrumentation , Humans , Incisor/blood supply , Incisor/innervation , Mandible/blood supply , Mandibular Nerve/pathology , Patient Care Planning , Radiography, Bitewing/methods , Trigeminal Nerve Injuries/diagnostic imaging
6.
Dent Mater J ; 32(3): 367-75, 2013.
Article in English | MEDLINE | ID: mdl-23718995

ABSTRACT

The purpose of this study was to evaluate the effect of denture cleansers on the surface roughness, hardness and color stability of two polyamides (Valpast, Deflex), a butadiene styrene copolymer PMMA (Rodex), and PMMA polymer as a control group (Paladent). Each material was divided into 5 sub-groups (n=7) as two control and three test groups. Three test groups were immersed for 20 days in commercially available three denture cleansers (CO-Corega, PR-Protefix, VA-Valclean). Two-way analysis of variance and Tukey's post hoc HSD test were used to evaluate surface roughness and hardness data (α=0.05). ΔE, ΔL*, Δa*and Δb* mean values were used for ANOVA, Tamhane test was used as post hoc. Polyamides showed low hardness and high roughness before and after immersion. A significant decrease in hardness was observed for all resins except Rodex after immersion (p<0.05). The denture cleansers changed the roughness, hardness and color of some resins.


Subject(s)
Denture Bases , Denture Cleansers , Nylons , Polymethyl Methacrylate , Resins, Synthetic , Color , Hardness , Materials Testing , Surface Properties
7.
J Prosthodont ; 22(1): 69-73, 2013 Jan.
Article in English | MEDLINE | ID: mdl-22985354

ABSTRACT

PURPOSE: Oxygenating agents like carbamide peroxide or H(2) O(2) are commonly used whitening agents. They have varying influence on the color and surface roughness of resin-based restorative materials and teeth. The aim of this study was to evaluate the effect of an at-home peroxide whitening agent applied through a whitening strip on the color and surface roughness of a nanofilled composite resin and an ormocer-based resin. MATERIALS AND METHODS: Disc-shaped (2 mm thick, 10 mm diameter) nanofilled resin composite (n = 10) and ormocer (n = 10) specimens were prepared. All specimens were treated with a whitening strip. Whitening procedures were performed applying a 6.5% hydrogen peroxide whitening strip (Crest White Strips Professional) for 30 minutes twice each day for a period of 21 consecutive days. During the test intervals, the specimens were rinsed under running distilled water for 1 minute to remove the whitening agents and immersed in 37°C distilled water until the next treatment. Surface roughness and color of the specimens were measured with a profilometer and a colorimeter, respectively, before and after whitening. Color changes were calculated (ΔE) using L*, a*, and b* coordinates. Repeated measures of variance analysis and Duncan test were used for statistical evaluation (α= 0.05). RESULTS: The average surface roughness of composite increased from 1.4 Ra to 2.0 Ra, and from 0.8 Ra to 0.9 Ra for the ormocer material; however, these changes in roughness after whitening were not significant (p > 0.05). Also, when two materials were compared, the surface roughness of restorative materials was not different before and after whitening (p > 0.05). L* and b* values for each material changed significantly after whitening (p < 0.05). ΔE values (before/after whitening) calculated for composite (11.9) and ormocer (16.1) were not significantly different from each other (p > 0.05). CONCLUSIONS: The tested whitening agent did not affect the surface roughness of either resin-based restorative material. Both materials became brighter after whitening. The behavior of the materials in the yellow/blue axis was opposite to each other after whitening. Each material had clinically unacceptable color change after whitening (ΔE > 5.5); however, the magnitude of the color change of materials was similar (p > 0.05). According to the results of this study, with the use of materials tested, patients should be advised that existing composite restorations may bleach along with the natural teeth, and replacement of these restorations after whitening may not be required.


Subject(s)
Composite Resins , Organically Modified Ceramics , Prosthesis Coloring , Tooth Bleaching Agents , Bisphenol A-Glycidyl Methacrylate , Color , Dental Restoration, Permanent , Hydrogen Peroxide , Materials Testing , Nanocomposites , Polyethylene Glycols , Polymethacrylic Acids , Surface Properties
8.
J Oral Implantol ; 39(5): 609-14, 2013 Oct.
Article in English | MEDLINE | ID: mdl-21942399

ABSTRACT

This case report details a 65-year-old male patient who underwent mandibular resection and radiotherapy as treatment for squamous cell carcinoma of the right mandible. The patient was rehabilitated with an implant-supported fixed partial denture and a maxillary occlusal ramp. The patient has been wearing his prosthesis for 2 years with no complaints.


Subject(s)
Carcinoma, Squamous Cell/rehabilitation , Dental Implantation, Endosseous , Dental Prosthesis, Implant-Supported , Mandible/surgery , Mandibular Neoplasms/rehabilitation , Aged , Carcinoma, Squamous Cell/radiotherapy , Carcinoma, Squamous Cell/surgery , Denture, Partial, Fixed , Humans , Male , Mandibular Neoplasms/radiotherapy , Mandibular Neoplasms/surgery , Osseointegration
9.
Eur J Dent ; 6(2): 212-7, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22509126

ABSTRACT

The majority of maxillary defects can be rehabilitated with conventional simple obturator prosthesis. However, inadequate retention, stability and support may be associated with the use of an obturator. Precision attachments have been used to retain obturators for some time. The use of precision attachments in a dentate maxillectomy patient can yield significant functional improvement while maintaining the obturator's aesthetic advantages. This clinical report describes the prosthetic rehabilitation of two maxillary defects with an obturator retained using extracoronal resilient precision attachments.

10.
J Appl Biomater Funct Mater ; 10(1): 37-42, 2012 Jun 26.
Article in English | MEDLINE | ID: mdl-22328342

ABSTRACT

INTRODUCTION: Microwave and water bath postpolymerization have been suggested as methods to improve the mechanical properties of heat and autopolymerizing acrylic resins. However, the effects of autoclave heating on the fracture properties of autopolymerizing acrylic resins have not been investigated. PURPOSE: The aim of this study was to assess the effectiveness of various autoclave postpolymerization methods on the fracture properties of 3 different autopolymerizing acrylic resins. METHODS: Forty-two specimens of 3 different autopolymerizing acrylic resins (Orthocryl, Paladent RR and Futurajet) were fabricated (40x8x4mm), and each group was further divided into 6 subgroups (n=7). Control group specimens remained as processed (Group 1). The first test group was postpolymerized in a cassette autoclave at 135°C for 6 minutes and the other groups were postpolymerized in a conventional autoclave at 130°C using different time settings (5, 10, 20 or 30 minutes). Fracture toughness was then measured with a three-point bending test. Data were analyzed by ANOVA followed by the Duncan test (α=0.05). RESULTS: The fracture toughness of Orthocryl and Paladent-RR acrylic resins significantly increased following conventional autoclave postpolymerization at 130°C for 10 minutes (P<.05). However, the fracture toughness of autoclave postpolymerized Futurajet was not significantly different than its control specimens (P<.05). The fracture toughness of Futurajet was significantly less than Paladent RR and Orthocryl specimens when autoclaved at 130°C for 10 minutes. CONCLUSIONS: Within the limitations of this study, it can be suggested that autoclave postpolymerization is an effective method for increasing the fracture toughness of tested autoploymerized acrylic resins.


Subject(s)
Acrylic Resins/chemistry , Resins, Synthetic/chemistry , Hot Temperature , Polymerization , Shear Strength , Sterilization
11.
Cleft Palate Craniofac J ; 48(3): 342-7, 2011 May.
Article in English | MEDLINE | ID: mdl-20815722

ABSTRACT

This case study reports on the prosthetic rehabilitation of a patient with an unrepaired bilateral cleft lip and palate using osseointegrated implants, extracoronal resilient attachments, a combination of metal-ceramic cement-retained fixed partial restorations, and removable prosthesis. Preoperative clinical examination of a 32-year-old woman with bilateral cleft lip and palate revealed a large oronasal communication, hyperplastic soft tissue surrounding the hard palate defect, and a severely resorbed alveolar ridge. A maxillary obturator prosthesis supported by implants and retained with an extracoronal resilient attachment was designed to cover the oronasal communication in the hard palate and fulfill the patient's functional and aesthetic requirements. The patient has been wearing the prosthesis for 1 year. Her speech quality has greatly improved, and her aesthetic and functional expectations have been met.


Subject(s)
Cleft Lip/complications , Cleft Palate/complications , Dental Implantation, Endosseous/methods , Dental Implants , Jaw, Edentulous, Partially/rehabilitation , Palatal Obturators , Adult , Crowns , Female , Humans , Jaw, Edentulous, Partially/etiology , Maxilla , Radiography, Panoramic
12.
J Craniofac Surg ; 21(5): 1538-41, 2010 Sep.
Article in English | MEDLINE | ID: mdl-20856044

ABSTRACT

Adult patients who did not receive proper treatment for cleft palate are challenging for clinicians in terms of prosthetic rehabilitation. Moreover, during the late stages of adulthood when patients become edentulous, prosthetic reconstruction becomes even more challenging. This clinical report describes the prosthetic rehabilitation of 2 edentulous geriatric patients with unrepaired cleft palate by placement of dental implants after closure of the oronasal communications.


Subject(s)
Cleft Palate/surgery , Dental Implants , Denture, Complete , Denture, Overlay , Jaw, Edentulous/surgery , Humans , Male , Middle Aged , Treatment Outcome
13.
Quintessence Int ; 39(3): e134-8, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18618029

ABSTRACT

OBJECTIVE: To evaluate retentive strength and film thickness of complete metal crowns cemented to overtapered teeth with 3 different cements after the application of airborne-particle abrasion. METHOD AND MATERIALS: Sixty extracted maxillary molar teeth were embedded in autopolymerizing resin. Crowns were prepared with 30-degree overtapered axial walls and a 1-mm shoulder margin using a water-cooled cylindrical airborne-particle abrasion device. Then, 60 complete crowns were made from a nickel-chromium alloy. Teeth and crowns were assigned to 2 groups, 30 to the control group and 30 to the experimental group to undergo airborne-particle abrasion. In the first part of study, 30 teeth from the experimental group were submitted to the silicon-replica technique and their buccolingual cross sections were measured so that cement film thickness could be measured before airborne-particle abrasion. Three measurements using a light microscope were made in 7 regions of each tooth. In the second part of study, complete metal crowns with and without airborne-particle abrasion were distributed into 3 groups with 10 teeth each to be cemented with zinc phosphate, polycarboxylate, or resin-modified glass ionomer. All specimens were subjected to a tensile bond test in an universal testing machine at a crosshead speed of 0.1 mm/min until failure. The results were then evaluated with Student t test at a 5% level of significance. RESULTS: The film thickness showed no statistically significant differences among groups (P > .05). There was a significant difference between the control and experimental groups, with an increase in all 3 cements after airborne-particle abrasion (P < .05). The highest retentive strength in the control group was found with resin-modified glass ionomer (141.4 +/- 56.7 N), but there was no significant difference between the resin-modified glass ionomer (141.4 +/- 56.7 N) and zinc phosphate (121.4 +/- 24.2 N) (P > .05). Retentive strength of polycarboxylate was the lowest (78.03 +/- 16 N) (P < .05). For the experimental group, the difference among the zinc phosphate (220.5 +/- 83.8 N), polycarboxylate (185.4 +/- 60.8 N), and resin-modified glass ionomer (228.9 +/- 62.4 N) was not statistically significant (P > .05). CONCLUSION: Airborne-particle abrasion had a positive effect on the retention of complete metal crowns when the crowns were cemented with zinc phosphate cement, polycarboxylate cement, or resin-modified glass-ionomer cement.


Subject(s)
Air Abrasion, Dental , Cementation/methods , Crowns , Dental Prosthesis Retention , Tooth Preparation, Prosthodontic/methods , Chromium Alloys , Dental Stress Analysis , Glass Ionomer Cements , Humans , Molar , Polycarboxylate Cement , Tensile Strength , Zinc Phosphate Cement
14.
Eur J Dent ; 2(2): 96-101, 2008 Apr.
Article in English | MEDLINE | ID: mdl-19212518

ABSTRACT

OBJECTIVES: The aim of this study was to investigate the effects of fiber-reinforced resin burs on the surface roughness of a nanofilled composite. METHODS: Average surface roughness values (Ra, mum) were measured using a surface profilometer and surface textures after finishing procedures were evaluated using a scanning electron microscope (SEM). Thirty cylindrical specimens were prepared using sectional teflon molds. A nanofilled composite was chosen. After the preparation specimens were divided into three subgroups randomly. After profilometric measurements, representative samples of the mentioned finishing procedures were selected and SEM analyses were carried out. RESULTS: Mylar strip group was statistically different from the other two groups (P<.05). The smoothest surfaces occurred when composite resin samples were light cured against the strips. On the other hand there was no statistical difference between fiber-reinforced resin burs and Sof-Lex discs (P>.05). For fiber-reinforced resin burs scratches and pitting which may be due to plucking of the filler particles during finishing were observed on the surface topography of the composite resin material. On the other hand, for the Sof-Lex discs although scratches were noticed on the surface topography, no pitting was observed. CONCLUSIONS: Fiber-reinforced resin burs can be preferred for the grinding of composite surplus in interproximal surfaces, where the use of Sof-Lex discs can be harmful to soft tissues.

15.
Quintessence Int ; 35(8): 655-6, 2004 Sep.
Article in English | MEDLINE | ID: mdl-15366532

ABSTRACT

A nasal prosthesis can reestablish esthetic form and anatomic contours for midfacial defects often more effectively than can surgical reconstruction. This case report describes the clinical and laboratory procedures for fabricating a nasal prosthesis.


Subject(s)
Nose Neoplasms/rehabilitation , Nose , Prostheses and Implants , Aged , Carcinoma, Basal Cell/rehabilitation , Dimethylpolysiloxanes , Humans , Male , Prosthesis Design , Silicones
SELECTION OF CITATIONS
SEARCH DETAIL
...