Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
G Ital Nefrol ; 37(3)2020 Jun 10.
Article in Italian | MEDLINE | ID: mdl-32530148

ABSTRACT

Valle d'Aosta, Italy's smallest region, faced a Covid-19 epidemic trend of absolute relevance. In line with data concerning the local general population, the predominance of the illness among uremic patients has been high. The authors report here preliminary data on the spread of this disease within the region and on the clinical trend of the infected patients who needed to be hospitalised.


Subject(s)
Betacoronavirus , Coronavirus Infections/epidemiology , Pandemics , Pneumonia, Viral/epidemiology , Renal Dialysis , Aged , Aged, 80 and over , COVID-19 , Data Analysis , Female , Global Health/statistics & numerical data , Humans , Italy/epidemiology , Male , Middle Aged , Prevalence , SARS-CoV-2 , Treatment Outcome
2.
G Ital Nefrol ; 37(1)2020 Feb 12.
Article in Italian | MEDLINE | ID: mdl-32068363

ABSTRACT

Atrial fibrillation is the most common cardiac disorder among chronic nephropathic patients. Possible therapeutic approaches include the use of anticoagulants, which are able to reduce the risk of thromboembolism but lead to an increasing bleeding risk, especially in this cohort of patients. Also, novel oral anticoagulant agents (NAO), due to their mainly renal clearance, are a relative contraindication in advanced renal disease. As an alternative to the oral anticoagulant therapy, left atrial appendage occlusion seems a promising opportunity in high risk, difficult to manage patients. Since there is limited evidence of LAAO in advanced chronic renal disease or dialysis patients, we report here a monocenter experience on 12 patients (6 of which in regular dialytic treatment) with a median clinical follow-up of fourteen months (3-22 months).


Subject(s)
Atrial Appendage , Atrial Fibrillation/complications , Renal Insufficiency, Chronic/complications , Therapeutic Occlusion/instrumentation , Thromboembolism/prevention & control , Aged , Aged, 80 and over , Anticoagulants/adverse effects , Atrial Appendage/diagnostic imaging , Contraindications, Drug , Factor Xa Inhibitors/therapeutic use , Hemorrhage/chemically induced , Humans , Middle Aged , Prospective Studies , Prosthesis Design , Renal Dialysis , Renal Insufficiency, Chronic/therapy , Risk Assessment , Thromboembolism/etiology
3.
G Ital Nefrol ; 36(4)2019 Jul 24.
Article in Italian | MEDLINE | ID: mdl-31373468

ABSTRACT

In the last few years, the increasing awareness of the complex interaction between monoclonal component and renal damage has determined not only a new classification of the associated disorders, called Monoclonal Gammopathy of Renal Significance (MGRS), but has also contributed to emphasize the importance of an early diagnosis of the renal involvement, which is often hard to detect but can evolve towards terminal uraemia; it has also pointed at the need to treat these disorders with aggressive regimens, even if they are not strictly neoplastic. The case described here presented urinary abnormalities and renal failure secondary to a membranoproliferative glomerulonephritis (MPGN), with intensively positive immunofluorescence (IF) for monoclonal k light chain and C3, and in the absence of a neoplastic lympho-proliferative disorder documented on bone marrow biopsy. After the final diagnosis of MGRS, the patient was treated with several cycles of a therapy including dexamethasone, cyclophosphamide and bortezomib, showing a good functional and clinical response.


Subject(s)
Glomerulonephritis, Membranoproliferative/complications , Paraproteinemias/complications , Renal Insufficiency/etiology , Biopsy , Bortezomib/therapeutic use , Complement C3c , Cyclophosphamide/therapeutic use , Dexamethasone/therapeutic use , Early Diagnosis , Female , Glomerulonephritis, Membranoproliferative/diagnosis , Glomerulonephritis, Membranoproliferative/pathology , Glucocorticoids/therapeutic use , Humans , Immunoglobulin kappa-Chains , Kidney Glomerulus/pathology , Kidney Glomerulus/ultrastructure , Middle Aged , Paraproteinemias/drug therapy
4.
G Ital Nefrol ; 34(1)2017.
Article in Italian | MEDLINE | ID: mdl-28177096

ABSTRACT

Hyponatremia is the most common electrolyte disorder observed in hospitalized patients. The most severe forms are neurological and potentially fatal emergencies; yet increased morbidity, length of hospital stay and costs associated with less severe forms are aspects of major concern. Nephrologists are frequently consulted regarding the therapeutic management and the key pathophysiological issues of hyponatremia, as this latter aspect represents a true challenge in an emergency setting. We report a case of a woman admitted to the emergency room for gait instability caused by a very severe multifactorial hyponatremia with a favourable clinical outcome.


Subject(s)
Hyponatremia/etiology , Female , Humans , Hyponatremia/diagnosis , Middle Aged , Severity of Illness Index
5.
G Ital Nefrol ; 32(6)2015.
Article in Italian | MEDLINE | ID: mdl-26845210

ABSTRACT

Theophylline/aminophylline use for asthma and chronic obstructive pulmonary disease has declined over time, as new and safer therapies developed. However, theophylline/aminophylline overdose can occur. Hereby it is described an unusual case of severe aminophylline intoxication due to mesodermic injections treated with CVVHDF session.


Subject(s)
Aminophylline/poisoning , Acute Disease , Adult , Female , Humans
6.
G Ital Nefrol ; 31(6)2014.
Article in Italian | MEDLINE | ID: mdl-25504165

ABSTRACT

Lactic acidosis metformin-related is a potentially fatal complication. Reviews show a stable prevalence of this phenomenon, but nephrological experience is required since it is frequently involved in therapeutic management. Here we report the cases of two old patients with severe lactic acidosis and acute renal failure treated with hemodiafiltration.


Subject(s)
Acidosis, Lactic/chemically induced , Hypoglycemic Agents/adverse effects , Metformin/adverse effects , Aged, 80 and over , Female , Humans , Male
7.
J Nephrol ; 23(1): 111-8, 2010.
Article in English | MEDLINE | ID: mdl-20091494

ABSTRACT

BACKGROUND: The aim of clinical risk management is to improve the quality of care provided by health care organizations and to assure patients' safety. Failure mode and effect analysis (FMEA) is a tool employed for clinical risk reduction. We applied FMEA to chronic hemodialysis outpatients. METHODS: FMEA steps: (i) process study: we recorded phases and activities. (ii) Hazard analysis: we listed activity-related failure modes and their effects; described control measures; assigned severity, occurrence and detection scores for each failure mode and calculated the risk priority numbers (RPNs) by multiplying the 3 scores. Total RPN is calculated by adding single failure mode RPN. (iii) Planning: we performed a RPNs prioritization on a priority matrix taking into account the 3 scores, and we analyzed failure modes causes, made recommendations and planned new control measures. (iv) Monitoring: after failure mode elimination or reduction, we compared the resulting RPN with the previous one. RESULTS: Our failure modes with the highest RPN came from communication and organization problems. Two tools have been created to ameliorate information flow: "dialysis agenda" software and nursing datasheets. We scheduled nephrological examinations, and we changed both medical and nursing organization. Total RPN value decreased from 892 to 815 (8.6%) after reorganization. CONCLUSIONS: Employing FMEA, we worked on a few critical activities, and we reduced patients' clinical risk. A priority matrix also takes into account the weight of the control measures: we believe this evaluation is quick, because of simple priority selection, and that it decreases action times.


Subject(s)
Equipment Failure Analysis/methods , Renal Dialysis/instrumentation , Risk Management/methods , Equipment Failure , Humans , Italy , Outpatients
8.
J Nephrol ; 22(2): 232-40, 2009.
Article in English | MEDLINE | ID: mdl-19384841

ABSTRACT

BACKGROUND: Intradialytic morbid events (IMEs) during haemodialysis (HD), including symptomatic hypotension, are related to ultrafiltration (UF)-induced hypovolaemia. Blood volume monitoring and automatic feedback control of the UF rate were developed to limit the extent of hypovolaemia during dialysis. The present study investigated the effect of blood volume (BV)-controlled UF on the incidence of HD treatments with IMEs. METHODS: This prospective randomised crossover study included hypotension-prone patients, characterised by occurrence of IMEs in at least 33% of HD treatments during a 6-week screening phase. These patients underwent 2 treatment phases, each lasting 6 weeks, in randomised order. Each patient served as their own control, treated with standard HD in one phase and with BV-controlled UF in the other phase. RESULTS: Thirty-four patients from 9 HD centres were enrolled; 26 could be included in the analysis population. In comparison with standard HD, BV-controlled UF reduced the percentage of HD sessions complicated by IME significantly from 40%+/-27% to 32%+/-25% (p=0.02). A lower frequency of HD sessions with IME could be observed in 46% of the patients. The frequency of treatments with symptomatic hypotension was reduced from 32%+/-23% in standard HD to 24%+/-21% with BV-controlled UF (p=0.04). Changes in blood pressure and heart rate from start to end of the HD session were not different between the 2 treatment modes. CONCLUSIONS: This crossover study showed improved intradialytic stability with BV-controlled UF, compared with standard HD.


Subject(s)
Blood Volume/physiology , Fluid Therapy/methods , Hypotension, Orthostatic/physiopathology , Hypotension/physiopathology , Hypovolemia/physiopathology , Renal Dialysis/adverse effects , Aged , Blood Volume Determination , Cross-Over Studies , Female , Follow-Up Studies , Humans , Hypertonic Solutions/administration & dosage , Hypotension/etiology , Hypotension/prevention & control , Hypotension, Orthostatic/etiology , Hypotension, Orthostatic/prevention & control , Hypovolemia/complications , Hypovolemia/therapy , Infusions, Intravenous , Isotonic Solutions/administration & dosage , Male , Prospective Studies , Renal Dialysis/methods , Time Factors , Treatment Outcome
9.
Nephrol Dial Transplant ; 22(5): 1420-7, 2007 May.
Article in English | MEDLINE | ID: mdl-17299006

ABSTRACT

BACKGROUND: Automatic systems for stabilizing blood pressure (BP) during dialysis are few and only control those variables indirectly related to BP. Due to complex BP regulation under dynamic dialysis conditions, BP itself appears to be the most consistent input parameter for a device addressed to preventing dialysis hypotension (DH). METHODS: An automatic system (ABPS, automatic blood pressure stabilization) for BP control by fluid removal feedback regulation is implemented on a dialysis machine (Dialog Advanced, Braun). A fuzzy logic (FL) control runs in the system, using instantaneous BP as the input variable governing the ultrafiltration rate (UFR) according to the BP trend. The system is user-friendly and just requires the input of two data: critical BP (individually defined as the possible level of DH risk) and the highest UFR applicable (percentage of the mean UFR). We evaluated this system's capacity to prevent DH in 55 RDT hypotension-prone patients. Sessions with (treatment A) and without (treatment B) ABPS were alternated one-by-one for 30 dialysis sessions per patient (674 with ABPS vs 698 without). RESULTS: Despite comparable treatment times and UF volumes, severe DH appeared in 8.3% of sessions in treatment A vs 13.8% in treatment B (-39%, P=0.01). Mild DH fell non-significantly (-12.3%). There was a similar percentage of sessions in which the planned body weight loss was not achieved and dialysis time was prolonged. CONCLUSIONS: In conclusion, FL may be suited to interpreting and controlling the trend of a determined multi-variable parameter like BP. The medical knowledge of the patient and the consequent updating of input parameters depending on the patient's clinical conditions seem to be the main factors for obtaining optimal results.


Subject(s)
Fuzzy Logic , Hypotension/prevention & control , Renal Dialysis/adverse effects , Renal Dialysis/methods , Biofeedback, Psychology/physiology , Blood Pressure/physiology , Female , Humans , Hypotension/etiology , Hypotension/psychology , Kidney Failure, Chronic/physiopathology , Kidney Failure, Chronic/psychology , Kidney Failure, Chronic/therapy , Male , Middle Aged , Prospective Studies , Renal Dialysis/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...