Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Artif Organs ; 45(7): 696-705, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33350485

ABSTRACT

Despite improved outcomes of modern continuous-flow left ventricular assist devices (CF-LVADs), device exchange is still needed for various indications. While the majority of CF-LVADs are exchanged to the same model, exchange to a different pump model is occasionally warranted. In this meta-analysis, we sought to consolidate the existing evidence to better elucidate the indications and outcomes in these cases. A comprehensive systematic search of adult patient cohorts who underwent CF-LVAD exchange to a different CF-LVAD model was performed. Study-level data from 10 studies comprising 98 patients were extracted and pooled for analysis. Mean patient age was 58 (95% CI: 48-65) and 81% were male. Indication for initial CF-LVAD was ischemic cardiomyopathy in 45% (34-57). Initial device was HeartMate II LVAD (HMII) in 93 (94.9%) and HeartWare HVAD (HW) in 5 (5.1%) patients. After mean CF-LVAD support time of 18.8 (15.2-22.4) months, exchange indications included thrombosis in 71% (43-89), infection in 21% (8-47) and device malfunction in 12% (7-21). HMII to HW exchange occurred in 53 (54.1%) patients, HMII to HeartMate III (HM3) in 32 (32.7%), and HM II to either HW or HM3 in 13 (13.2%) patients. Postoperatively, right ventricular assist device was required in 16% (8-32). Overall, 20% (8-40) of patients experienced a stroke, while HW patients had a significantly higher stroke incidence than HM3 patients (HW: 21% (8-47) vs. HM3: 5% (1-24), P < .01). Overall 30-day mortality was 10% (6-17), while HW had a significantly worse 30-day mortality than HM3 (HW: 13% (7-24) vs. HM3: 5% (1-24), P = .03). Following device exchange from a different CF-LVAD model, HM3 is associated with lower stroke and higher survival when compared to HW.


Subject(s)
Device Removal , Heart-Assist Devices/adverse effects , Equipment Failure , Heart Failure/therapy , Humans , Infections/complications , Stroke/etiology , Thrombosis/complications
2.
Artif Organs ; 45(6): 559-568, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33190331

ABSTRACT

Modern extracorporeal life-support (ECLS) technology has been successfully utilized to treat patients with diffuse alveolar damage (DAD) and diffuse alveolar hemorrhage (DAH); however, reports in the literature remain scarce. We sought to pool existing evidence to better characterize ECLS use in these patients. An electronic search was conducted to identify all studies in the English literature reporting the use of ECLS for DAD/DAH. Thirty-two articles consisting of 38 patients were selected, and patient-level data were extracted and pooled for analysis. Median patient age was 36 [IQR: 27, 48] years, and the majority (63.2%) were female. Most common etiological factors included granulomatosis with polyangiitis (8/38, 21.1%), systemic lupus erythematosus (8/38, 21.1%), Goodpasture's syndrome (4/38, 10.5%), and microscopic polyangiitis (4/38, 10.5%). Immunologic markers included anti-neutrophil cytoplasmic antibody (ANCA) in 15/38 (39.5%), anti-nuclear antibody (ANA) in 6/38 (15.8%), and anti-glomerular basement membrane (anti-GBM) antibodies in 4/38 (10.5%). DAH was present in 32/38 (84.2%) of cases and DAD without evidence of DAH was present in 6/38 (15.8%) of cases. ECLS strategies included extracorporeal membrane oxygenation of veno-venous type (VV-ECMO) in 28/38 (73.7%), veno-arterial type (VA-ECMO) in 5/38 (13.2%), and one case of right ventricular assist device with oxygenator (RVAD-ECMO). Heparin was utilized in 18/38 (47.4%) of cases with no difference in use between DAH versus no DAH (P = .46) or VA- versus VV-ECLS (P = 1). Median duration of ECLS was 10 [5, 14] days. Pre- versus post-ECLS comparison of blood gases showed improvement in median PaO2 (49 [45, 59] mm Hg vs. 80 [70, 99] mm Hg, P < .001), PaO2:FiO2 ratio (48.2 [41.4, 54.8] vs. 182.0 [149.4, 212.2], P < .01), and pulse oximetry values (76% [72, 80] vs. 96% [94, 97], P = .086). Overall, 94.7% (36/38) of patients survived to decannulation while 30-day mortality was 10.5% (4/38) with no differences between VA- and VV-ECMO (P = 1 and P = .94, respectively). DAD/DAH occurs in a younger, predominantly female population, and tends to be associated with systemic autoimmune processes. ECLS, independent of its type, appears to result in favorable short-term survival.


Subject(s)
Extracorporeal Membrane Oxygenation , Hemorrhage/therapy , Lung Diseases/therapy , Pulmonary Alveoli/pathology , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...