Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Otol Neurotol ; 43(2): 206-211, 2022 02 01.
Article in English | MEDLINE | ID: mdl-34669684

ABSTRACT

OBJECTIVE: Demonstrate the ability of a novel steerable distal chip endoscope to traverse the Eustachian tube and provide diagnostic quality images of the human middle ear. PATIENTS: Three cadaveric temporal bone specimens were used in this work. INTERVENTION: Diagnostic transeustachian endoscopy of the middle ear was performed. MAIN OUTCOME MEASURE: Diagnostic image quality. RESULTS: A novel 1.62 mm steerable endoscope successfully cannulated the Eustachian tube of three human cadaveric temporal bone specimens to reveal intact middle ear anatomy with high optical clarity. CONCLUSIONS: A steerable endoscope can be designed to traverse the human Eustachian tube and provide diagnostic quality images of middle ear anatomy.


Subject(s)
Ear, Middle , Eustachian Tube , Cadaver , Ear, Middle/anatomy & histology , Ear, Middle/diagnostic imaging , Ear, Middle/surgery , Endoscopes , Endoscopy/methods , Eustachian Tube/diagnostic imaging , Eustachian Tube/surgery , Humans
2.
J Med Robot Res ; 6(1-2)2021.
Article in English | MEDLINE | ID: mdl-36017195

ABSTRACT

This paper presents a new mechanics model for unidirectional notched-tube continuum wrists, a class of mechanisms frequently used to implement distal steering in needle-sized surgical robotic instruments. Existing kinematic models available for these devices are based on the simplifying assumption that, during actuation, all the notches undergo the same amount of deflection, so that the shape of a wrist can be approximated by an arc of constant curvature. This approach is analytically attractive, but, as we show in this paper, it can sometimes fail to provide good tracking accuracy. In this article, we provide a new model that relaxes the assumption above, and we report experimental evidence showing its superior accuracy. We model wrist deflection using Castigliano's second theorem, with the addition of a capstan friction term that accounts for frictional losses on the actuation tendon. Because notched-tube wrists are typically made of Nickel-Titanium (Nitinol), which has nonlinear stress-strain characteristics, we use a technique to obtain a local linearized approximation of the material modulus, suitable for use in the deflection model. The result of our modeling is a system of nonlinear equations that can be solved numerically to predict the wrist configuration based on the applied actuation force. Experimental results on physical specimens show that this improved model provides a more accurate estimate of wrist kinematics than prior models assuming constant curvature bending.

3.
Int Symp Med Robot ; 2020: 188-194, 2020 Nov.
Article in English | MEDLINE | ID: mdl-36844884

ABSTRACT

This paper presents a computational framework to optimize the visual coverage attainable by a notched-tube continuum robotic endoscope inside the middle ear cavity. Our framework combines anatomically-accurate geometric (mesh) models of the middle ear with a sampling-based motion planning algorithm (RRT) and a ray-casting procedure to quantify what regions of the middle ear can be accessed and visualized by the endoscope. To demonstrate the use of this framework, we run computer simulations to investigate the effect of varying the distance between each pair of consecutive flexure elements (i.e., notches) in our robotic endoscope.

4.
Ann Biomed Eng ; 48(1): 181-191, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31342337

ABSTRACT

New robotic systems have recently emerged to assist with peripheral lung access, but a robotic system for rigid bronchoscopy has yet to be developed. We describe a new robotic system that can deliver thin robotic manipulators through the ports of standard rigid bronchoscopes. The manipulators bend and elongate to provide maneuverability of surgical tools at the endoscope tip, without endoscope motion. We describe an initial feasibility study on the use of this system to bronchoscopically treat a central airway obstruction (CAO). CAO is prevalent and can be life-threatening in patients with large tumors, and conventional rigid bronchoscopic treatments place patients at risk of complications including broken teeth, neck trauma and damage to oropharyngeal structures due to significant forces induced by bronchoscope tilting and manipulation. In this study, we used an ex vivo ovine airway model to demonstrate the ability of a physician using the robotic system to efficiently remove tissue and restore the airway. Pre- and post-operative CT scans showed that the robot was able to reduce the degree of airway obstruction stenosis from 75 to 14% on average for five CAO resections performed in an ex vivo animal model. Using cadaver experiments, we demonstrated the potential of the robotic system to substantially reduce the intraoperative forces applied to the patient's head and neck (from 80.6 to 4.1 N). These preliminary results illustrate that CAO removal is feasible with our new rigid bronchoscopy robot system, and that this approach has the potential to reduce forces applied to the patient due to bronchoscope angulation, and thereby reduce the risk of complications encountered during CAO surgery.


Subject(s)
Airway Obstruction/surgery , Bronchoscopy/instrumentation , Robotics , Animals , Cadaver , Feasibility Studies , Sheep
SELECTION OF CITATIONS
SEARCH DETAIL
...