Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Vasc Endovasc Surg ; 66(3): 313-321, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37406878

ABSTRACT

OBJECTIVE: To report outcomes of the Advanta V12 as a covered bridging stent in fenestrated and branched endovascular aneurysm repair (F/BEVAR). METHODS: Patients treated with F/BEVAR and followed in a single centre receiving the Advanta V12 as a covered bridging stent between January 2010 and May 2020 were included. RESULTS: A total of 636 patients (543 men) were analysed. A total of 1 675 target vessels (TVs) were bridged with the Advanta V12. Estimated TV patency at one, five, and eight years was 99.1% ± 0.2%, 96.9% ± 0.5% and 96.2% ± 0.7%, respectively. Estimated patency at eight years was 98.1% ± 0.5% for fenestrations and 87.3% ± 2.9% for branches (p < .001). Estimated patency of renal arteries was statistically significantly lower for those targeted with branches compared with fenestrations (p = .001). Multivariable analysis showed that targeting a TV with a branch compared with a fenestration was the only independent risk factor for occlusion during follow up (hazard ratio 6.41, 95% CI 3.4 - 11.9; p < .001). Estimated freedom from endoleak at one, five, and eight years was 99.4% ± 0.2%, 96.4% ± 0.6%, and 95.4% ± 0.8%, respectively. Estimated freedom from target vessel instability (TVI) at one, five, and eight years was 98.5% ± 0.3%, 93.0% ± 0.8%, and 91.3% ± 1%, respectively. Estimated freedom from TVI at eight years was 93.2% ± 0.9% for fenestrations and 82.7% ± 3.5% for branches (p < .001). Estimated freedom from TVI was statistically significantly lower for renal arteries targeted with branches compared with those targeted with fenestrations (p < .001) CONCLUSION: The Advanta V12 shows excellent technical success rates as a covered bridging stent in F/ΒEVAR. Late outcomes remain good with low rates of TV occlusion, endoleak, and re-intervention. Renal arteries targeted with branches demonstrated a higher risk of occlusion and instability compared with those targeted with fenestrations.

3.
Ann Vasc Surg ; 75: 445-454, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33823248

ABSTRACT

BACKGROUND: This study analyses limb occlusion rates after endovascular aneurysm repair (EVAR) with a strategy including stent-graft limb selection and liberal primary stenting (relining) in anatomies at higher risk for occlusion with uncovered self-expandable or balloon-expandable stents. METHODS: All patients undergoing elective EVAR with a bifurcated stent-graft between January 2010-August 2018 were included. A protocol involving personalized stent-graft selection and liberal primary relining based on preoperative imaging was followed during the whole period. Primary endpoints were technical success and primary limb patency during follow-up. Secondary endpoints included mortality and limb reintervention rates. Risk factors associated to limb patency and reintervention rates were analyzed. RESULTS: Six hundred and fifteen patients (548 males; mean age 72.9 ± 9 years) were included. Overall technical success was 98.5% (606/615). One (0.16%) patient died during the first 30 days. Of the 1230 limbs, 96 (8%) were deemed at risk for occlusion in view of the anatomy, and primarily relined in 62 patients. Estimated primary limb patency at 6 months, 1 year and 3 years was 99.5 ± 0.2%, 99.2 ± 0.3% and 98.5 ± 0.5%, respectively. Freedom from limb-related reintervention at 6 months, 1 year and 3 years was 98.1 ± 0.4%, 97.4 ± 0.5% and 95.6 ± 0.7%, respectively. Only one (1%) of the 96 relined limbs occluded during follow-up. No differences were found in terms of patency or freedom from reintervention between limbs at risk that were primary stented and limbs without adjunctive stents. Gore Excluder stent-grafts presented better patency (Breslow P = 0.005) and lower reintervention rates (Breslow P = 0.001) than other devices during follow-up. Peripheral artery disease was also a risk factor for reintervention (Breslow P = 0.015). CONCLUSION: Liberal use of primary limb relining in patients with iliac anatomy at higher risk for occlusion appears to be a safe and effective strategy to preserve limb patency after EVAR. Gore Excluder graft limbs present better patency and lower reintervention rates than other stent-graft types.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Graft Occlusion, Vascular/surgery , Iliac Artery/surgery , Stents , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/physiopathology , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Female , Graft Occlusion, Vascular/diagnostic imaging , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/physiopathology , Humans , Iliac Artery/diagnostic imaging , Iliac Artery/physiopathology , Male , Middle Aged , Prosthesis Design , Reoperation , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , Vascular Patency
4.
J Cardiovasc Surg (Torino) ; 61(4): 427-434, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32319276

ABSTRACT

BACKGROUND: Aneurysmal degeneration after acute dissection occurs in a significant proportion of patients. Fenestrated and branched stent-grafting (F/BEVAR) has been increasingly used to treat these post-dissection thoracoabdominal aortic aneurysms (PD-TAAA). The aim of this study was to report early and mid-term outcomes of F/BEVAR in PD-TAAA. METHODS: Retrospective single center analysis of a prospectively maintained database including all patients undergoing F/BEVAR for PD-TAAA between October 2010-February 2020. RESULTS: Fifty-five patients (45 males, mean age 66±10 years) were included. Technical success was achieved in all patients. Thirty-day mortality was two (3.6%) patients. Major perioperative complications were noted in nine (16.4%) patients including five (9.1%) with transient spinal cord ischemia (SCI) and one (1.8%) with permanent paraplegia. Mean follow-up was 24 months (1-76 months). Cumulative survival rates at 12, 24 and 36 months were 87±5.5%, 83.5±6.3% and 72.2±8.1%, respectively. Estimated freedom from reintervention at 12, 24 and 36 months was 82.2±6.7%, 60.1±9.2% and 55.9±9.5%, respectively. Main reasons for reintervention were endoleaks from target vessels and common iliac arteries. Estimated target vessel patency at 12, 24 and 36 months was 97.8±1.2%, 95.4±2.1%, and 94.1±2.4%, respectively. Mean aneurysm sac regression during follow-up was 7.9±7.1 mm, with complete false lumen thrombosis in 80% of patients. No ruptures occurred during follow-up. CONCLUSIONS: F/BEVAR for PD-TAAA is associated with low perioperative mortality and morbidity in a large volume endovascular center. Mid-term results demonstrate a high rate of aneurysm sac regression. Extended sealing with longer bridging stents for target vessels is recommended.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis , Endovascular Procedures , Aged , Chronic Disease , Female , Humans , Male , Postoperative Complications , Retrospective Studies , Stents
SELECTION OF CITATIONS
SEARCH DETAIL
...