1.
Health Phys ; 82(4): 473-83, 2002 Apr.
Article in English | MEDLINE | ID: mdl-11906136

ABSTRACT

Electromagnetic field standards in the West are based on well-established acute biological effects that could be considered as signaling a potentially adverse health effect. The specific absorption rate, which is proportional to the tissue heating (thermal effects), represents the basic restriction of exposure to Radio-Frequency (RF) fields. On the other hand, Eastern European standards are designed to protect from potential non-thermal effects that might be caused by chronic exposure to very low intensities, where a so-called "power load" (a product of field intensity and duration of exposure) represents the basic limitation. Thus, electromagnetic field standards in Eastern European countries differ considerably from those which are proposed by the International Commission of Non-ionizing Radiation Protection and the Standards Coordinating Committee 28 of the Institute of Electrical and Electronics Engineers, Inc. In the present paper, the strategies for development of exposure limit values in electromagnetic fields standards currently in force in Eastern and Central European countries are discussed. Some differences as well as similarities of the national health and safety standards and the main obstacles to harmonization of these standards with those being established by Western national and international organizations and agencies are presented.


Subject(s)
Electromagnetic Fields , Environmental Exposure/prevention & control , Radio Waves , Europe , Europe, Eastern , Humans , International Cooperation , Maximum Allowable Concentration , Occupational Exposure
2.
Bioelectromagnetics ; 23(1): 37-48, 2002 Jan.
Article in English | MEDLINE | ID: mdl-11793404

ABSTRACT

Rapid increase in the use of numerical techniques to predict current density or specific absorption rate (SAR) in sophisticated three dimensional anatomical computer models of man and animals has resulted in the need to understand how numerical solutions of the complex electrodynamics equations match with empirical measurements. This aspect is particularly important because different numerical codes and computer models are used in research settings as a guide in designing clinical devices, telecommunication systems, and safety standards. To ensure compliance with safety guidelines during equipment design, manufacturing and maintenance, realistic and accurate models could be used as a bridge between empirical data and actual exposure conditions. Before these tools are transitioned into the hands of health safety officers and system designers, their accuracy and limitations must be verified under a variety of exposure conditions using available analytical and empirical dosimetry techniques. In this paper, empirical validation of SAR values predicted by finite difference time domain (FDTD) numerical code on sphere and rat is presented. The results of this study show a good agreement between empirical and theoretical methods and, thus, offer a relatively high confidence in SAR predictions obtained from digital anatomical models based on the FDTD numerical code.


Subject(s)
Computer Simulation , Electromagnetic Fields/adverse effects , Models, Biological , Animals , Body Temperature , Humans , Male , Models, Anatomic , Rats , Rats, Sprague-Dawley
3.
IEEE Trans Biomed Eng ; 48(10): 1169-77, 2001 Oct.
Article in English | MEDLINE | ID: mdl-11585041

ABSTRACT

The development and widespread use of advanced three-dimensional digital anatomical models to calculate specific absorption rate (SAR) values in biological material has resulted in the need to understand how model parameters (e.g., permittivity value) affect the predicted whole-body and localized SAR values. The application of the man dosimetry model requires that permittivity values (dielectric value and conductivity) be allocated to the various tissues at all the frequencies to which the model will be exposed. In the 3-mm-resolution man model, the permittivity values for all 39 tissue-types were altered simultaneously for each orientation and applied frequency. In addition, permittivity values for muscle, fat, skin, and bone marrow were manipulated independently. The finite-difference time-domain code was used to predict localized and whole-body normalized SAR values. The model was processed in the far-field conditions at the resonant frequency (70 MHz) and above (200, 400, 918, and 2060 MHz) for E orientation. In addition, other orientations (K, H) of the model to the incident fields were used where no substantial resonant frequency exists. Variability in permittivity values did not substantially influence whole-body SAR values, while localized SAR values for individual tissues were substantially affected by these changes. Changes in permittivity had greatest effect on localized SAR values when they were low compare to the whole-body SAR value or when errors involved tissues that represent a substantial proportion of the body mass (i.e., muscle). Furthermore, we establish the partial derivative of whole-body and localized SAR values with respect to the dielectric value and conductivity for muscle independently. It was shown that uncertainties in dielectric value or conductivity do not substantially influence normalized whole-body SAR. Detailed investigation on localized SAR ratios showed that conductivity presents a more substantial factor in absorption of energy in tissues than dielectric value for almost all applied exposure conditions.


Subject(s)
Electromagnetic Fields , Radiometry/methods , Absorption , Humans , Models, Anatomic , Organ Specificity , Radiation Dosage
4.
Bioelectromagnetics ; 22(6): 384-400, 2001 Sep.
Article in English | MEDLINE | ID: mdl-11536280

ABSTRACT

Specific absorption rate (SAR) value is dependent on permittivity value. However, variability in the published permittivity values for human and animal tissue and the development of sophisticated 3-dimensional digital anatomical models to predict SAR values has resulted in the need to understand how model parameters (permittivity value) affect the predicted whole body and localized SAR values. In this paper, we establish the partial derivative of whole body SARs and localized SAR values (defined as SAR for individual organs with respect to a change in the permittivity values of all tissue types, as well as for those tissues with the most variable permittivity values. Variations in the published permittivity values may substantially influence whole body and localized SAR values, but only under special conditions. Orientation of the exposed object to the incident electromagnetic wave is one of the most crucial factors. Published 2001 Wiley-Liss, Inc.


Subject(s)
Electromagnetic Fields , Radiation Dosage , Radio Waves , Animals , Male , Models, Anatomic , Muscle, Skeletal/radiation effects , Organ Specificity , Rats , Rats, Sprague-Dawley
SELECTION OF CITATIONS