Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Med Image Anal ; 97: 103276, 2024 Jul 17.
Article in English | MEDLINE | ID: mdl-39068830

ABSTRACT

Radiation therapy plays a crucial role in cancer treatment, necessitating precise delivery of radiation to tumors while sparing healthy tissues over multiple days. Computed tomography (CT) is integral for treatment planning, offering electron density data crucial for accurate dose calculations. However, accurately representing patient anatomy is challenging, especially in adaptive radiotherapy, where CT is not acquired daily. Magnetic resonance imaging (MRI) provides superior soft-tissue contrast. Still, it lacks electron density information, while cone beam CT (CBCT) lacks direct electron density calibration and is mainly used for patient positioning. Adopting MRI-only or CBCT-based adaptive radiotherapy eliminates the need for CT planning but presents challenges. Synthetic CT (sCT) generation techniques aim to address these challenges by using image synthesis to bridge the gap between MRI, CBCT, and CT. The SynthRAD2023 challenge was organized to compare synthetic CT generation methods using multi-center ground truth data from 1080 patients, divided into two tasks: (1) MRI-to-CT and (2) CBCT-to-CT. The evaluation included image similarity and dose-based metrics from proton and photon plans. The challenge attracted significant participation, with 617 registrations and 22/17 valid submissions for tasks 1/2. Top-performing teams achieved high structural similarity indices (≥0.87/0.90) and gamma pass rates for photon (≥98.1%/99.0%) and proton (≥97.3%/97.0%) plans. However, no significant correlation was found between image similarity metrics and dose accuracy, emphasizing the need for dose evaluation when assessing the clinical applicability of sCT. SynthRAD2023 facilitated the investigation and benchmarking of sCT generation techniques, providing insights for developing MRI-only and CBCT-based adaptive radiotherapy. It showcased the growing capacity of deep learning to produce high-quality sCT, reducing reliance on conventional CT for treatment planning.

2.
Med Phys ; 51(4): 2499-2509, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37956266

ABSTRACT

BACKGROUND: Deep learning has shown promising results to generate MRI-based synthetic CTs and to enable accurate proton dose calculations on MRIs. For clinical implementation of synthetic CTs, quality assurance tools that verify their quality and reliability are required but still lacking. PURPOSE: This study aims to evaluate the predictive value of uncertainty maps generated with Monte Carlo dropout (MCD) for verifying proton dose calculations on deep-learning-based synthetic CTs (sCTs) derived from MRIs in online adaptive proton therapy. METHODS: Two deep-learning models (DCNN and cycleGAN) were trained for CT image synthesis using 101 paired CT-MR images. sCT images were generated using MCD for each model by performing 10 inferences with activated dropout layers. The final sCT was obtained by averaging the inferred sCTs, while the uncertainty map was obtained from the HU variance corresponding to each voxel of 10 sCTs. The resulting uncertainty maps were compared to the observed HU-, range-, WET-, and dose-error maps between the sCT and planning CT. For range and WET errors, the generated uncertainty maps were projected along the 90-degree angle. To evaluate the dose distribution, a mask based on the 5%-isodose curve was applied to only include voxels along the beam paths. Pearson's correlation coefficients were calculated to determine the correlation between the uncertainty maps and HUs, range, WET, and dose errors. To evaluate the dosimetric accuracy of synthetic CTs, clinical proton treatment plans were recalculated and compared to the pCTs RESULTS: Evaluation of the correlation showed an average of r = 0.92 ± 0.03 and r = 0.92 ± 0.03 for errors between uncertainty-HU, r = 0.66 ± 0.09 and r = 0.62 ± 0.06 between uncertainty-range, r = 0.64 ± 0.06 and r = 0.58 ± 0.07 between uncertainty-WET, and r = 0.65 ± 0.09 and r = 0.67 ± 0.07 between uncertainty and dose difference for DCNN and cycleGAN model, respectively. Dosimetric comparison for target volumes showed an average 3%/3 mm gamma pass rate of 99.76 ± 0.43 (DCNN) and 99.10 ± 1.27 (cycleGAN). CONCLUSION: The observed correlations between uncertainty maps and the various metrics (HU, range, WET, and dose errors) demonstrated the potential of MCD-based uncertainty maps as a reliable QA tool to evaluate the accuracy of deep learning-based sCTs.


Subject(s)
Deep Learning , Proton Therapy , Tomography, X-Ray Computed/methods , Proton Therapy/methods , Protons , Feasibility Studies , Reproducibility of Results , Uncertainty , Radiotherapy Planning, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Radiotherapy Dosage , Image Processing, Computer-Assisted/methods
3.
Med Phys ; 50(7): 4664-4674, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37283211

ABSTRACT

PURPOSE: Medical imaging has become increasingly important in diagnosing and treating oncological patients, particularly in radiotherapy. Recent advances in synthetic computed tomography (sCT) generation have increased interest in public challenges to provide data and evaluation metrics for comparing different approaches openly. This paper describes a dataset of brain and pelvis computed tomography (CT) images with rigidly registered cone-beam CT (CBCT) and magnetic resonance imaging (MRI) images to facilitate the development and evaluation of sCT generation for radiotherapy planning. ACQUISITION AND VALIDATION METHODS: The dataset consists of CT, CBCT, and MRI of 540 brains and 540 pelvic radiotherapy patients from three Dutch university medical centers. Subjects' ages ranged from 3 to 93 years, with a mean age of 60. Various scanner models and acquisition settings were used across patients from the three data-providing centers. Details are available in a comma separated value files provided with the datasets. DATA FORMAT AND USAGE NOTES: The data is available on Zenodo (https://doi.org/10.5281/zenodo.7260704, https://doi.org/10.5281/zenodo.7868168) under the SynthRAD2023 collection. The images for each subject are available in nifti format. POTENTIAL APPLICATIONS: This dataset will enable the evaluation and development of image synthesis algorithms for radiotherapy purposes on a realistic multi-center dataset with varying acquisition protocols. Synthetic CT generation has numerous applications in radiation therapy, including diagnosis, treatment planning, treatment monitoring, and surgical planning.


Subject(s)
Image Processing, Computer-Assisted , Radiotherapy, Image-Guided , Humans , Child, Preschool , Child , Adolescent , Young Adult , Adult , Middle Aged , Aged , Aged, 80 and over , Image Processing, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Cone-Beam Computed Tomography , Pelvis , Radiotherapy, Image-Guided/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Magnetic Resonance Imaging/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...