Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Publication year range
1.
Gastroenterol. hepatol. (Ed. impr.) ; 47(3): 246-252, mar. 2024. ilus, tab, graf
Article in English | IBECS | ID: ibc-231205

ABSTRACT

Background and objectives There are few scales with prospective validation for the assessment of the upper gastrointestinal mucosal cleanliness during an esophagogastroduodenoscopy (EGD). The aim of this study was to develop a valid and reproducible cleanliness scale for use during an EGD. Methods We developed a cleanliness scale (Barcelona scale) with a score (0–2 points) of five segments of the upper gastrointestinal tract with thorough cleaning techniques (esophagus, fundus, body, antrum, and duodenum). First, 125 photos (25 of each area) were assessed, and a score was assigned to each image by consensus among 7 experts endoscopists. Subsequently, 100 of the 125 images were selected and the inter- and intra-observer variability of 15 previously trained endoscopists was evaluated using the same images at two different times. Results In total, 1500 assessments were performed. In 1336/1500 observations (89%) there was agreement with the consensus score, with a mean kappa value of 0.83 (0.45–0.96). In the second evaluation, in 1330/1500 observations (89%) there was agreement with the consensus score, with a mean kappa value of 0.82 (0.45–0.93). The intra-observer variability was 0.89 (0.76–0.99). Conclusions The Barcelona cleanliness scale is a valid measure and reproducible with minimal training. Its application in clinical practice is a significant step to standardize the quality of the EGD. (AU)


Introducción Existen pocas escalas validadas prospectivamente para evaluar la limpieza de la mucosa esofagogastroduodenal durante la endoscopia digestiva alta (EDA). El objetivo de este estudio fue desarrollar una escala válida y reproducible para su uso en la realización de una EDA. Métodos Desarrollamos una escala de limpieza (escala Barcelona) en la que se aplicó una puntuación de 0 a 2 a cinco áreas del tracto digestivo superior (esófago, fundus, cuerpo, antro y duodeno) después de haber realizado todas las maniobras de lavado necesarias. Inicialmente, se evaluaron 125 fotos (25 de cada área) y se asignó una puntuación (de 0 a 2) a cada una por consenso entre siete endoscopistas. Posteriormente, se seleccionaron 100 de las 125 fotografías y se evaluó la variabilidad inter e intraobservador de 15 endoscopistas previamente formados utilizando las mismas imágenes en dos momentos diferentes. Resultados Se efectuaron un total de 1.500 observaciones. En 1.336/1.500 de ellas (89%) hubo coincidencia con la puntuación del consenso, siendo el valor medio de kappa de 0,83 (0,45-0,96). En la segunda evaluación, en 1.330/1.500 observaciones (89%) hubo coincidencia con la puntuación del consenso, siendo el valor medio de kappa de 0,82 (mínimo 0,45 y máximo 0,93). La variabilidad intraobservador fue de 0,89 (0,76-0,99). Conclusiones La escala de limpieza Barcelona es una medida válida y reproducible con un mínimo entrenamiento. Su uso en la práctica clínica podría ser un paso significativo para estandarizar la calidad de la EDA. (AU)


Subject(s)
Endoscopy, Digestive System/methods , Endoscopy, Digestive System/statistics & numerical data , Prospective Studies
2.
Gastroenterol Hepatol ; 47(3): 246-252, 2024 Mar.
Article in English, Spanish | MEDLINE | ID: mdl-37236304

ABSTRACT

BACKGROUND AND OBJECTIVES: There are few scales with prospective validation for the assessment of the upper gastrointestinal mucosal cleanliness during an esophagogastroduodenoscopy (EGD). The aim of this study was to develop a valid and reproducible cleanliness scale for use during an EGD. METHODS: We developed a cleanliness scale (Barcelona scale) with a score (0-2 points) of five segments of the upper gastrointestinal tract with thorough cleaning techniques (esophagus, fundus, body, antrum, and duodenum). First, 125 photos (25 of each area) were assessed, and a score was assigned to each image by consensus among 7 experts endoscopists. Subsequently, 100 of the 125 images were selected and the inter- and intra-observer variability of 15 previously trained endoscopists was evaluated using the same images at two different times. RESULTS: In total, 1500 assessments were performed. In 1336/1500 observations (89%) there was agreement with the consensus score, with a mean kappa value of 0.83 (0.45-0.96). In the second evaluation, in 1330/1500 observations (89%) there was agreement with the consensus score, with a mean kappa value of 0.82 (0.45-0.93). The intra-observer variability was 0.89 (0.76-0.99). CONCLUSIONS: The Barcelona cleanliness scale is a valid measure and reproducible with minimal training. Its application in clinical practice is a significant step to standardize the quality of the EGD.


Subject(s)
Duodenum , Mucous Membrane , Humans , Consensus , Endoscopy, Digestive System
3.
Rev Esp Enferm Dig ; 2023 Nov 30.
Article in English | MEDLINE | ID: mdl-38031917

ABSTRACT

BACKGROUND: Older adults are increasing in number and frequently seeking hospital care for acute illness. We aimed to measure the utilization and safety of ERCP in patients aged 85 and older in our hospital. METHODS: This is a single-site, retrospective, observational and descriptive study. We obtained data about admissions and ERCP utilization from our hospital database. We reviewed medical and procedural records of patients aged 85 or older who underwent ERCP for choledocholithiasis between 2013 and 2019. We evaluated technical and medical adverse events after ERCP. RESULTS: 494 ERCP for choledocholithiasis were performed during this period and 154 (31%) were aged 85 or older. We identified 567 (4.8%) admissions for biliary tract diseases in the older population, and 27% of cases had required ERCP. In older patients, the rate of technical adverse events was around 10%. There was no statistical difference between the older and younger groups regarding technical complications (8.8 vs 9.7%; p=0.7). Besides, in 36% of cases, a medical event, decompensated comorbidity or geriatric syndromes appeared after ERCP. The overall mortality for any cause at six months was nearly 20%, and the survival rate was significantly lower in patients who develop adverse events (technical or medical). CONCLUSIONS: Our hospital experiences frequent utilization of ERCP by patients aged 85 and older. Although technical adverse event rates are similar to those of younger adults, medical events appear frequently. We plan to strengthen our care plans for older adults and hope to reduce the medical complications experienced post ERCP.

SELECTION OF CITATIONS
SEARCH DETAIL
...