Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Language
Publication year range
1.
Cir. plást. ibero-latinoam ; 42(3): 227-232, jul.-sept. 2016. ilus
Article in Spanish | IBECS | ID: ibc-157044

ABSTRACT

Antecedentes y Objetivos. El concepto de marcación abdominal o six packs ha incrementado su demanda entre los pacientes que consultan por remodelación corporal. El uso en liposucción del ultrasonido quirúrgico de tercera generación permite mejorar los resultados y lograr mayor definición de las zonas tratadas. Sin embargo, no está exento de complicaciones como quemaduras cutáneas. Nos planteamos demostrar la potencia y el tiempo de contacto cutáneo perjudicial para la piel. Material y Método. Desarrollamos un estudio experimental sobre 15 piezas de dermolipectomía empleando potencias de ultrasonido del 70% y del 100%, sometiendo las áreas predeterminadas a 15, 30, 45 y 60 segundos de acción sobre la dermis, y estudiándolas después por histopatología. Resultados. A potencia del 100% y más de 15 segundos próximos a la piel se desarrollaron áreas de epidermólisis (quemaduras de 2º grado), mientras que observamos rangos de seguridad, sin cambios histológicos, con el uso al 70% y 60 segundos en contacto directo con la dermis. Conclusiones. Este trabajo pretende, a través de un estudio experimental, dar parámetros de seguridad que ofrezcan tranquilidad al cirujano plástico cuando emplea el ultrasonido quirúrgico para liposucción en zonas próximas a la dermis (AU)


Background and Objectives. The concept of abdominal marking or six packs has increased its demand among patients who consult for body contouring. The use of ultrasound assisted lipoplasty third generation has improved results in body contouring and has achieved greater definition of the treated areas. But this is not exempt of complications, such as skin burns. Our aim is to demonstrate the power and time of detrimental cutaneous contact with the patient's skin. Methods. We developed an experimental study in 15 dermolipectomy specimens using powers of ultrasound at 70 y 100% and modifying action on the dermis exposure time from 15 to 30, 45 and 60 seconds These areas were studied by histopathology. Results. Our data showed that at 100% power and 15 seconds next to the skin, epidermolysis (2 degree burns) was developed, while the safety ranges (no histological changes) were observed using 70% power and 60 seconds in direct contact with the dermis. Conclusions. This paper intends, through an experimental study, giving security settings when using surgical ultrasound for liposuction in the proximity of cutaneous areas (AU)


Subject(s)
Humans , Lipectomy/methods , Ultrasonic Surgical Procedures/methods , Obesity, Abdominal/surgery , Plastic Surgery Procedures/methods , Body Fat Distribution , Patient Safety , Epidermolysis Bullosa Acquisita/epidemiology , Postoperative Complications/epidemiology
2.
Rev. argent. cir. plást ; 19(4): 83-89, 20130000.
Article in Spanish | LILACS, BINACIS | ID: biblio-1553685

ABSTRACT

En este trabajo se revaloriza el uso de videoendoscopia para el tratamiento de lesiones benignas frontales, con la presentación de 13 casos


In this paper, the use of video endoscopy revalued for the treatment of benign front tumors, with the presentation of 13 cases


Subject(s)
Humans , Male , Female , Video-Assisted Surgery/methods , Endoscopy/methods , Facial Injuries/surgery , Forehead/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...