Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Front Neurosci ; 15: 796203, 2021.
Article in English | MEDLINE | ID: mdl-34955740

ABSTRACT

Technological advancements in electronics and micromachining now allow the development of discrete wireless brain implantable micro-devices. Applications of such devices include stimulation or sensing and could enable direct placement near regions of interest within the brain without the need for electrode leads or separate battery compartments that are at increased risk of breakage and infection. Clinical use of leadless brain implants is accompanied by novel risks, such as migration of the implant. Additionally, the encapsulation material of the implants plays an important role in mitigating unwanted tissue reactions. These risks have the potential to cause harm or reduce the service of life of the implant. In the present study, we have assessed post-implantation tissue reaction and migration of borosilicate glass-encapsulated micro-implants within the cortex of the brain. Twenty borosilicate glass-encapsulated devices (2 × 3.5 × 20 mm) were implanted into the parenchyma of 10 sheep for 6 months. Radiographs were taken directly post-surgery and at 3 and 6 months. Subsequently, sheep were euthanized, and GFAP and IBA-1 histological analysis was performed. The migration of the implants was tracked by reference to two stainless steel screws placed in the skull. We found no significant difference in fluoroscopy intensity of GFAP and a small difference in IBA-1 between implanted tissue and control. There was no glial scar formation found at the site of the implant's track wall. Furthermore, we observed movement of up to 4.6 mm in a subset of implants in the first 3 months of implantation and no movement in any implant during the 3-6-month period of implantation. Subsequent histological analysis revealed no evidence of a migration track or tissue damage. We conclude that the implantation of this discrete micro-implant within the brain does not present additional risk due to migration.

2.
Micromachines (Basel) ; 11(10)2020 Sep 27.
Article in English | MEDLINE | ID: mdl-32992656

ABSTRACT

This paper presents a capacitive pressure sensor interface circuit design in 180 nm XH018 CMOS technology for an implantable capacitive pressure sensor, which has a wireless power supply and wireless data transfer function. It integrates full-bridge rectifiers, shorting control switches, low-dropout regulators, bandgap references, analog front end, single slope analog to digital converter (ADC), I2C, and an RC oscillator. The low-dropout regulators regulate the wireless power supply coming from the rectifier and provide a stable and accurate 1.8 V DC voltage to other blocks. The capacitance of the pressure sensor is sampled to a discrete voltage by the analog front end. The single slope ADC converts the discrete voltage into 11 bits of digital data, which is then converted into 1 kbps serial data out by the I2C block. The "1" of serial data is modulated to a 500 kHz digital signal that is used to control the shorting switch for wireless data transfer via inductive back scatter. This capacitive pressure sensor interface IC has a resolution of 0.98 mmHg (1.4 fF), average total power consumption of 7.8 mW, and ±3.2% accuracy at the worst case under a -20 to 80 °C temperature range, which improves to ±0.86% when operated between 20 and 60 °C.

SELECTION OF CITATIONS
SEARCH DETAIL
...