Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Main subject
Language
Publication year range
1.
Sensors (Basel) ; 24(8)2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38676237

ABSTRACT

In this work, we present a novel approach for improving the energy resolution from particles impinging on the interstrip regions of silicon strip detectors. We employed three double-sided strip detectors from the GRIT array and a triple α-source under laboratory conditions. The results showed that the interstrip resolution depends not only on the impinging side but also on whether it is a P- or an N-interstrip. We obtained the interstrip energy resolution down to 0.4%, and, depending on the scenario, the resolution was enhanced by a factor of 2. We believe that this new rotation method allows for the possibility of applying particle identification methods on interstrip events, which in most cases are dismissed during data recording.

2.
Sensors (Basel) ; 23(12)2023 Jun 07.
Article in English | MEDLINE | ID: mdl-37420550

ABSTRACT

This work deals with the characteristics of highly segmented double-sided silicon detectors. These are fundamental parts in many new state-of-the-art particle detection systems, and therefore they must perform optimally. We propose a test bench that can handle 256 electronic channels with off-the-shelf equipment, as well as a detector quality control protocol to ensure that the detectors meet the requirements. Detectors with a large number of strips bring new technological challenges and issues that need to be carefully monitored and understood. One of the standard 500 µm thick detectors of the GRIT array was investigated, undergoing studies that revealed its IV curve, charge collection efficiency, and energy resolution. From the data obtained, we calculated, among other things, the depletion voltage (110 V), the resistivity of the bulk material (9 kΩ·cm), and the electronic noise contribution (8 keV). We present, for the first time, a methodology called "the energy triangle'' to visualize the effect of charge sharing between two adjacent strips and to study the hit distribution with the interstrip-to-strip hit ratio (ISR).


Subject(s)
Silicon , Quality Control
3.
Phys Rev Lett ; 131(26): 262501, 2023 Dec 29.
Article in English | MEDLINE | ID: mdl-38215380

ABSTRACT

The excited states of unstable ^{20}O were investigated via γ-ray spectroscopy following the ^{19}O(d,p)^{20}O reaction at 8 AMeV. By exploiting the Doppler shift attenuation method, the lifetimes of the 2_{2}^{+} and 3_{1}^{+} states were firmly established. From the γ-ray branching and E2/M1 mixing ratios for transitions deexciting the 2_{2}^{+} and 3_{1}^{+} states, the B(E2) and B(M1) were determined. Various chiral effective field theory Hamiltonians, describing the nuclear properties beyond ground states, along with a standard USDB interaction, were compared with the experimentally obtained data. Such a comparison for a large set of γ-ray transition probabilities with the valence space in medium similarity renormalization group ab initio calculations was performed for the first time in a nucleus far from stability. It was shown that the ab initio approaches using chiral effective field theory forces are challenged by detailed high-precision spectroscopic properties of nuclei. The reduced transition probabilities were found to be a very constraining test of the performance of the ab initio models.

SELECTION OF CITATIONS
SEARCH DETAIL
...