1.
J Opt Microsyst ; 3(1)2023 Jan.
Article in English | MEDLINE | ID: mdl-38084130

ABSTRACT

Microendoscopes are commonly used in small lumens in the body, for which a focus near to the distal tip and ability to operate in an aqueous environment are paramount for navigation and disease detection. Commercially available distal optic systems below 1mm in diameter are severely limited, and custom micro lenses are generally very expensive. Gradient index of refraction (GRIN) singlets are available in small diameters but have limited optical performance adjustability. Three-dimensional (3D) printed monolithic optical systems are an emerging option that may be suitable for enabling high performance, close-focus imaging. In this manuscript, we compared the optical performance of three custom distal optic systems; a custom-pitch GRIN singlet, 3D-printed monolithic doublet, and 3D-printed monolithic triplet, with a nominal working distance (WD) of 1.5mm, 0.5mm and 0.4mm in 0.9% saline. These short WDs are ideal for microendoscopy in collapsed or flushed lumens such as pancreatic duct or fallopian tube. The GRIN singlet had performance limited only by the fiber bundle relay over 0.9mm to 1.6 mm depth of field (DOF). The 3D printed doublet was able to achieve a comparable DOF of 0.71mm, while the 3D printed triplet suffered the most limited DOF of 0.55mm. 3D printing enables flexible design of monolithic multi-element systems with aspheric surfaces of very short WDs and relative ease of integration.

2.
J Biomed Opt ; 28(12): 121206, 2023 12.
Article in English | MEDLINE | ID: mdl-37577082

ABSTRACT

Significance: High grade serous ovarian cancer is the most deadly gynecological cancer, and it is now believed that most cases originate in the fallopian tubes (FTs). Early detection of ovarian cancer could double the 5-year survival rate compared with late-stage diagnosis. Autofluorescence imaging can detect serous-origin precancerous and cancerous lesions in ex vivo FT and ovaries with good sensitivity and specificity. Multispectral fluorescence imaging (MFI) can differentiate healthy, benign, and malignant ovarian and FT tissues. Optical coherence tomography (OCT) reveals subsurface microstructural information and can distinguish normal and cancerous structure in ovaries and FTs. Aim: We developed an FT endoscope, the falloposcope, as a method for detecting ovarian cancer with MFI and OCT. The falloposcope clinical prototype was tested in a pilot study with 12 volunteers to date to evaluate the safety and feasibility of FT imaging prior to standard of care salpingectomy in normal-risk volunteers. In this manuscript, we describe the multiple modifications made to the falloposcope to enhance robustness, usability, and image quality based on lessons learned in the clinical setting. Approach: The ∼0.8 mm diameter falloposcope was introduced via a minimally invasive approach through a commercially available hysteroscope and introducing a catheter. A navigation video, MFI, and OCT of human FTs were obtained. Feedback from stakeholders on image quality and procedural difficulty was obtained. Results: The falloposcope successfully obtained images in vivo. Considerable feedback was obtained, motivating iterative improvements, including accommodating the operating room environment, modifying the hysteroscope accessories, decreasing endoscope fragility and fiber breaks, optimizing software, improving fiber bundle images, decreasing gradient-index lens stray light, optimizing the proximal imaging system, and improving the illumination. Conclusions: The initial clinical prototype falloposcope was able to image the FTs, and iterative prototyping has increased its robustness, functionality, and ease of use for future trials.


Subject(s)
Fallopian Tubes , Ovarian Neoplasms , Female , Humans , Pilot Projects , Ovarian Neoplasms/diagnostic imaging , Ovarian Neoplasms/pathology , Endoscopes
3.
J Eng Sci Med Diagn Ther ; 4(2): 021007, 2021 May 01.
Article in English | MEDLINE | ID: mdl-35832635

ABSTRACT

Piezoelectric tube actuators with cantilevered optical fibers have enabled the miniaturization of scanning image acquisition techniques for endoscopic implementation. To achieve raster scanning for such a miniaturized system, the first resonant frequency should be of the order of 10 s of Hz. We explore adding a mass at an intermediate location along the length of the fiber to alter the resonant frequencies of the system. We provide a mathematical model to predict resonant frequencies for a cantilevered beam with an intermediate mass. The theoretical and measured data match well for various fiber lengths, mass sizes, and mass attachment locations along the fiber.

4.
Article in English | MEDLINE | ID: mdl-36325111

ABSTRACT

We present the design and feasibility testing of a multimodal co-registered endoscope based on a dual-path optical system integrated with a scanning piezo. This endoscope incorporates three different imaging modalities. A large field of view reflectance imaging system enables visualization of objects several millimeters in front of the endoscope, while optical coherence microscopy and multiphoton microscopy are employed in contact with tissue to further analyze suspicious areas. The optical system allows multiple different imaging modalities by employing a dual optical path. One path features a low numerical aperture and wide field of view to allow reflectance imaging of distant objects. The other path features a high numerical aperture and short working distance to allow microscopy techniques such as optical coherence microscopy and multiphoton microscopy. Images of test targets were obtained with each imaging modality to verify and characterize the imaging capabilities of the endoscope. The reflectance modality was demonstrated with a 561 nm laser to allow high contrast with blood vessels. It achieved a lateral resolution of 24.8 µm at 5 mm and a working distance from 5 mm to 30 mm. Optical coherence microscopy (OCM) was performed with a 1300 nm super-luminescent diode since this wavelength experiences low relative scattering to allow for deeper tissue imaging. Measured OCM lateral and axial resolution was 4.0 µm and 14.2 µm, respectively. Multiphoton microscopy (MPM) was performed with a custom 1400 nm femtosecond fiber laser, a wavelength suitable for exciting multiple exogenous and some endogenous fluorophores, as well as providing information on tissue composition through harmonic generation processes. A 4.0 µm MPM lateral resolution was measured.