Braz. j. med. biol. res ; 43(12): 1160-1166, Dec. 2010. ilus
Article in English | LILACS | ID: lil-569007

ABSTRACT

The main objective of the present study was to upgrade a clinical gamma camera to obtain high resolution tomographic images of small animal organs. The system is based on a clinical gamma camera to which we have adapted a special-purpose pinhole collimator and a device for positioning and rotating the target based on a computer-controlled step motor. We developed a software tool to reconstruct the target’s three-dimensional distribution of emission from a set of planar projections, based on the maximum likelihood algorithm. We present details on the hardware and software implementation. We imaged phantoms and heart and kidneys of rats. When using pinhole collimators, the spatial resolution and sensitivity of the imaging system depend on parameters such as the detector-to-collimator and detector-to-target distances and pinhole diameter. In this study, we reached an object voxel size of 0.6 mm and spatial resolution better than 2.4 and 1.7 mm full width at half maximum when 1.5- and 1.0-mm diameter pinholes were used, respectively. Appropriate sensitivity to study the target of interest was attained in both cases. Additionally, we show that as few as 12 projections are sufficient to attain good quality reconstructions, a result that implies a significant reduction of acquisition time and opens the possibility for radiotracer dynamic studies. In conclusion, a high resolution single photon emission computed tomography (SPECT) system was developed using a commercial clinical gamma camera, allowing the acquisition of detailed volumetric images of small animal organs. This type of system has important implications for research areas such as Cardiology, Neurology or Oncology.


Subject(s)
Animals , Male , Rats , Gamma Cameras/veterinary , Heart , Kidney , Models, Animal , Tomography, Emission-Computed, Single-Photon/veterinary , Algorithms , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Phantoms, Imaging , Rats, Wistar , Tomography, Emission-Computed, Single-Photon/instrumentation , Tomography, Emission-Computed, Single-Photon/methods
2.
Braz J Med Biol Res ; 43(12): 1160-6, 2010 Dec.
Article in English | MEDLINE | ID: mdl-21085887

ABSTRACT

The main objective of the present study was to upgrade a clinical gamma camera to obtain high resolution tomographic images of small animal organs. The system is based on a clinical gamma camera to which we have adapted a special-purpose pinhole collimator and a device for positioning and rotating the target based on a computer-controlled step motor. We developed a software tool to reconstruct the target's three-dimensional distribution of emission from a set of planar projections, based on the maximum likelihood algorithm. We present details on the hardware and software implementation. We imaged phantoms and heart and kidneys of rats. When using pinhole collimators, the spatial resolution and sensitivity of the imaging system depend on parameters such as the detector-to-collimator and detector-to-target distances and pinhole diameter. In this study, we reached an object voxel size of 0.6 mm and spatial resolution better than 2.4 and 1.7 mm full width at half maximum when 1.5- and 1.0-mm diameter pinholes were used, respectively. Appropriate sensitivity to study the target of interest was attained in both cases. Additionally, we show that as few as 12 projections are sufficient to attain good quality reconstructions, a result that implies a significant reduction of acquisition time and opens the possibility for radiotracer dynamic studies. In conclusion, a high resolution single photon emission computed tomography (SPECT) system was developed using a commercial clinical gamma camera, allowing the acquisition of detailed volumetric images of small animal organs. This type of system has important implications for research areas such as Cardiology, Neurology or Oncology.


Subject(s)
Gamma Cameras/veterinary , Heart/diagnostic imaging , Kidney/diagnostic imaging , Models, Animal , Tomography, Emission-Computed, Single-Photon/veterinary , Algorithms , Animals , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Male , Phantoms, Imaging , Rats , Rats, Wistar , Tomography, Emission-Computed, Single-Photon/instrumentation , Tomography, Emission-Computed, Single-Photon/methods
3.
Brain Res Bull ; 81(6): 595-9, 2010 Apr 05.
Article in English | MEDLINE | ID: mdl-20100550

ABSTRACT

The elevated plus-maze is an animal model used to study anxiety. In a second session, rats show a reduction in the exploratory behavior even when the two sessions are separated by intervals as large as 7 days. The aim of the present study was to investigate whether the reduction in the exploratory behavior is maintained after intervals larger than 7 days. Additionally, we aimed at investigating eventual correlations between behaviors in the plus-maze and activation of limbic structures as measured by Fos protein expression after the second session. Rats were tested for 5 min in the elevated plus-maze and re-tested 3, 9 or 33 days later. Other groups were tested only once. The rat brains were processed for immunohistochemical detection of Fos protein. The results show a decrease in the open arms exploration in the second trial with intervals of 3, 9 and 33 days. The expression of Fos protein in the piriform cortex, septal nucleus and paraventricular hypothalamic nucleus in the groups tested with intervals of 9 and 33 days were statistically different from the other groups. The alterations observed in exploratory behavior in the second session in the plus-maze did not correlate with Fos expression. In conclusion, although the specific test conditions were sufficient to evoke behavioral alterations in exploration in the elevated plus-maze, they were enough to induce significant Fos protein expression in piriform cortex, septal nucleus and thalamic and hypothalamic paraventricular nuclei but not in other areas such as dorsomedial nucleus of the hypothalamus and amygdala nuclei, known to be also active participants in circuits controlling fear and anxiety.


Subject(s)
Exploratory Behavior/physiology , Limbic System/metabolism , Maze Learning/physiology , Proto-Oncogene Proteins c-fos/metabolism , Analysis of Variance , Animals , Cell Count , Cell Nucleus/metabolism , Cerebral Cortex/metabolism , Immunohistochemistry , Male , Motor Activity/physiology , Neurons/metabolism , Paraventricular Hypothalamic Nucleus/metabolism , Psychomotor Performance/physiology , Rats , Rats, Wistar , Septal Nuclei/metabolism , Time Factors
4.
Braz J Med Biol Res ; 42(8): 692-9, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19649396

ABSTRACT

Single-photon emission computed tomography (SPECT) is a non-invasive imaging technique, which provides information reporting the functional states of tissues. SPECT imaging has been used as a diagnostic tool in several human disorders and can be used in animal models of diseases for physiopathological, genomic and drug discovery studies. However, most of the experimental models used in research involve rodents, which are at least one order of magnitude smaller in linear dimensions than man. Consequently, images of targets obtained with conventional gamma-cameras and collimators have poor spatial resolution and statistical quality. We review the methodological approaches developed in recent years in order to obtain images of small targets with good spatial resolution and sensitivity. Multipinhole, coded mask- and slit-based collimators are presented as alternative approaches to improve image quality. In combination with appropriate decoding algorithms, these collimators permit a significant reduction of the time needed to register the projections used to make 3-D representations of the volumetric distribution of target's radiotracers. Simultaneously, they can be used to minimize artifacts and blurring arising when single pinhole collimators are used. Representation images are presented, which illustrate the use of these collimators. We also comment on the use of coded masks to attain tomographic resolution with a single projection, as discussed by some investigators since their introduction to obtain near-field images. We conclude this review by showing that the use of appropriate hardware and software tools adapted to conventional gamma-cameras can be of great help in obtaining relevant functional information in experiments using small animals.


Subject(s)
Computer-Aided Design , Imaging, Three-Dimensional/veterinary , Models, Biological , Tomography, Emission-Computed, Single-Photon/veterinary , Animals , Image Enhancement , Imaging, Three-Dimensional/methods , Reproducibility of Results , Sensitivity and Specificity , Tomography, Emission-Computed, Single-Photon/methods
5.
Braz. j. med. biol. res ; 42(8): 692-699, Aug. 2009. ilus
Article in English | LILACS | ID: lil-520790

ABSTRACT

Single-photon emission computed tomography (SPECT) is a non-invasive imaging technique, which provides information reporting the functional states of tissues. SPECT imaging has been used as a diagnostic tool in several human disorders and can be used in animal models of diseases for physiopathological, genomic and drug discovery studies. However, most of the experimental models used in research involve rodents, which are at least one order of magnitude smaller in linear dimensions than man. Consequently, images of targets obtained with conventional gamma-cameras and collimators have poor spatial resolution and statistical quality. We review the methodological approaches developed in recent years in order to obtain images of small targets with good spatial resolution and sensitivity. Multipinhole, coded mask- and slit-based collimators are presented as alternative approaches to improve image quality. In combination with appropriate decoding algorithms, these collimators permit a significant reduction of the time needed to register the projections used to make 3-D representations of the volumetric distribution of target’s radiotracers. Simultaneously, they can be used to minimize artifacts and blurring arising when single pinhole collimators are used. Representation images are presented, which illustrate the use of these collimators. We also comment on the use of coded masks to attain tomographic resolution with a single projection, as discussed by some investigators since their introduction to obtain near-field images. We conclude this review by showing that the use of appropriate hardware and software tools adapted to conventional gamma-cameras can be of great help in obtaining relevant functional information in experiments using small animals.


Subject(s)
Animals , Computer-Aided Design , Imaging, Three-Dimensional/veterinary , Models, Biological , Tomography, Emission-Computed, Single-Photon/veterinary , Image Enhancement , Imaging, Three-Dimensional/methods , Reproducibility of Results , Sensitivity and Specificity , Tomography, Emission-Computed, Single-Photon/methods
6.
Neuroscience ; 125(3): 787-802, 2004.
Article in English | MEDLINE | ID: mdl-15099692

ABSTRACT

Audiogenic seizures are a model of generalized tonic-clonic brainstem-generated seizures. Repeated induction of audiogenic seizures, in audiogenic kindling (AuK) protocols, generates limbic epileptogenic activity. The present work evaluated associations between permanence of AuK-induced limbic epileptogenicity and changes in cell number/gluzinergic terminal reorganization in limbic structures in Wistar audiogenic rats (WARs). Additionally, we evaluated histological changes after only amygdala kindling (AmK) and only AuK, and longevity of permanence of AuK-induced limbic epileptogenicity, up to 160 days. WARs and Wistar non-susceptible rats were submitted to AuK (80 stimuli) followed by both 50 days without acoustic stimulation and AmK (16 stimuli), only AmK and only AuK. Cell counting and gluzinergic terminal reorganization were assessed, respectively, by using Nissl and neo-Timm histochemistries, 24 h after the last AmK stimulus. Evaluation of behavioral response to a single acoustic stimulus after AuK and up to 160 days without acoustic stimulation was done in another group. AuK-induced limbic epileptogenicity developed in parallel with a decrease in brainstem-type seizure severity during AuK. AmK was facilitated after AuK. Permanence of AuK-induced limbic epileptogenicity was associated with cell loss only in the rostral lateral nucleus of amygdala. Roughly 20 generalized limbic seizures induced by AuK were neither associated with hippocampal cell loss nor mossy fiber sprouting (MFS). AmK developed with cell loss in hippocampal and amygdala nuclei but not MFS. Main changes of gluzinergic terminals after kindling protocols were observed in amygdala, perirhinal and piriform cortices. AuK and AuK-AmK induced a similar number and type of seizures, higher than in AmK. AmK and AuK-AmK were associated with broader cell loss than AuK. Data indicate that permanent AuK-induced limbic epileptogenicity is mainly associated to gluzinergic terminal reorganization in amygdala but not in the hippocampus and with no hippocampal cell loss. Few AmK-induced seizures are associated to broader and higher cell loss than a higher number of AuK-induced seizures.


Subject(s)
Amygdala/physiopathology , Epilepsy, Reflex/physiopathology , Kindling, Neurologic/genetics , Limbic System/physiopathology , Nerve Degeneration/genetics , Neuronal Plasticity/genetics , Acoustic Stimulation/adverse effects , Amygdala/pathology , Animals , Cell Count , Disease Models, Animal , Disease Progression , Epilepsy, Reflex/genetics , Epilepsy, Tonic-Clonic/genetics , Epilepsy, Tonic-Clonic/physiopathology , Female , Genetic Predisposition to Disease , Glutamic Acid/metabolism , Hippocampus/pathology , Hippocampus/physiopathology , Kindling, Neurologic/pathology , Limbic System/pathology , Mossy Fibers, Hippocampal/metabolism , Mossy Fibers, Hippocampal/ultrastructure , Nerve Degeneration/pathology , Nerve Degeneration/physiopathology , Presynaptic Terminals/metabolism , Presynaptic Terminals/pathology , Rats , Rats, Mutant Strains , Rats, Wistar
7.
Epilepsy Res ; 39(3): 251-9, 2000 May.
Article in English | MEDLINE | ID: mdl-10771251

ABSTRACT

Repetitive high intensity (110 dB) sound stimulation induces a forebrain-kindling phenomenon in animals predisposed to sound induced seizures. Wistar audiogenic rats (WARs) have been reported to develop a mixed brainstem-limbic seizure pattern, after more than five to ten stimuli. Besides the original brainstem wild running and tonic-clonic seizures, new behavioral patterns appear resembling those of electrical amygdala kindling. Although audiogenic kindling is a well-known phenomenon, electrographic limbic recruitment during the kindling has never been reported. Our objective was to use electrophysiology to test the hypothesis of gradual and sequential involvement of the amygdala and then cortex during audiogenic kindling. We used video-EEG recordings with cortical and deep electrode implants (inferior colliculus and basolateral amygdaloid nuclei) during audiogenic kindling on eight WARs, and their respective controls, submitted to a protocol of three acoustic stimuli per day. A new design for 'on site' source follower circuits was used in order to minimize noise during the recording of EEG data from the wild running episode and the subsequent tonic-clonic or motor limbic seizures. The video-EEG equipment assembled allowed synchronous recordings of both behavior and EEG. WARs first recordings showed electrodecremental responses after seizure onset and a probable epileptiform activity, particularly in the inferior colliculus, during the tonic phase of seizure. All animals showed very similar polyspike-wave activity in the amygdala, after behavioral seizure patterns (Racine's scale) occurred. The morphology of such epileptiform EEG activity is very similar to that reported for electrical amygdala kindling. Also, when audiogenic kindling continued, both inferior colliculus and cortical electrodes presented high amplitude and synchronized epileptiform polyspike activity.


Subject(s)
Kindling, Neurologic/physiology , Limbic System/physiology , Recruitment, Neurophysiological/physiology , Acoustic Stimulation , Animals , Brain/anatomy & histology , Brain/physiology , Electroencephalography , Limbic System/anatomy & histology , Rats , Rats, Wistar