Sci Rep ; 14(1): 8592, 2024 04 13.
Article in English | MEDLINE | ID: mdl-38615153

ABSTRACT

Multifocal contact lenses (MCLs) are one of the solutions to correct presbyopia, but their adoption is not widespread. To address this situation, visual simulators can be used to refine the adaptation process. This study aims to obtain accurate simulations for a visual simulator (SimVis Gekko; 2EyesVision) of daily soft MCL designs from four manufacturers. In-vitro characterization of these MCLs-several powers and additions- was obtained using NIMO TR-1504. From the averaged relative power profiles across powers, phase maps were reconstructed and the Through-Focus Visual Strehl metric was calculated for each MCL design. The SimVis Gekko simulation corresponding to each MCL design was obtained computationally and bench-validated. Finally, the MCL simulations were clinically validated involving presbyopic patients. The clinical validation results show a good agreement between the SimVis Gekko simulations and the real MCLs for through-focus visual acuity (TF-VA) curves and VA at three real distances. All MCL designs showed a partial correlation higher than 0.90 and a Root Mean Square Error below 0.07 logMAR between the TF-VA of simulations and Real MCLs across subjects. The validity of the simulation approach using SimVis Gekko and in-vitro measurements was confirmed in this study, opening the possibility to accelerate the adaptation of MCLs.


Subject(s)
Contact Lenses, Hydrophilic , Lizards , Presbyopia , Humans , Animals , Computer Simulation , Presbyopia/therapy , Visual Acuity
2.
Biomed Opt Express ; 14(9): 4468-4484, 2023 Sep 01.
Article in English | MEDLINE | ID: mdl-37791284

ABSTRACT

Whole-eye optical coherence tomography (OCT) imaging is a promising tool in ocular biometry for cataract surgery planning, glaucoma diagnostics and myopia progression studies. However, conventional OCT systems are set up to perform either anterior or posterior eye segment scans and cannot easily switch between the two scan configurations without adding or exchanging optical components to account for the refraction of the eye's optics. Even in state-of-the-art whole-eye OCT systems, the scan configurations are pre-selected and cannot be dynamically reconfigured. In this work, we present the design, optimization and experimental validation of a reconfigurable and low-cost optical beam scanner based on three electro-tunable lenses, capable of non-mechanically controlling the beam position, angle and focus. We derive the analytical theory behind its control. We demonstrate its use in performing alternate anterior and posterior segment imaging by seamlessly switching between a telecentric focused beam scan to an angular collimated beam scan. We characterize the corresponding beam profiles and record whole-eye OCT images in a model eye and in an ex vivo rabbit eye, observing features comparable to those obtained with conventional anterior and posterior OCT scanners. The proposed beam scanner reduces the complexity and cost of other whole-eye scanners and is well suited for 2-D ocular biometry. Additionally, with the added versatility of seamless scan reconfiguration, its use can be easily expanded to other ophthalmic applications and beyond.

3.
Sci Rep ; 13(1): 1575, 2023 Jan 28.
Article in English | MEDLINE | ID: mdl-36709218

ABSTRACT

Most tunable lenses (TLs) are affected by deviations in optical power induced by external temperature changes or due to internal heating while in use. This study proposes: (1) An experimental characterization method to evaluate the magnitude of the optical power deviations due to internal temperature shifts; (2) three different mathematical models (experimental, polynomial, and optimized) to describe the response of the lens with temperature; (3) predictions of the internal temperature shifts while using the lens in time frames of minutes, seconds, and milliseconds and; (4) a real time optical power compensation tool based on the implementation of the models on a custom voltage electronic driver. The compensation methods were successfully applied to two TL samples in static and dynamic experiments and in hysteresis cycles. After 40 min at a static nominal power of 5 diopters (dpt), the internal temperature exponentially increased by 17 °C, producing an optical power deviation of 1.0 dpt (1.5 dpt when the lens cools down), representing a 20% distortion for heating and 30% for cooling. Modelling and compensation reduced the deviations to 0.2 dpt when heating (0.35 dpt when cooling) and the distortions to 4% and 7%. Similar levels of improvement were obtained in dynamic and hysteresis experiments. Compensation reduced temperature effects by more than 75%, representing a significant improvement in the performance of the lens.

4.
Biomed Opt Express ; 14(12): 6521-6541, 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-38420323

ABSTRACT

Optical biometers are routinely used to measure intraocular distances in ophthalmic applications such as cataract surgery planning or myopia monitoring. However, due to their high cost and reduced transportability, access to them for screening and surgical planning is still limited in low-resource and remote settings. To increase patients' access to optical biometry we propose a novel low-cost frequency-domain optical delay line (FD-ODL) based on an inexpensive stepper motor spinning a tilted mirror, for integration into a time-domain (TD)-biometer, amenable to a compact footprint. In the proposed FD-ODL, the axial scan range and the A-scan rate are decoupled from one another, as the former only depends on the spinning mirror tilt angle, while the A-scan rate only depends on the motor shaft rotational speed. We characterized the scanning performance and specifications for two spinning mirror tilt angles, and compared them to those of the standard, more expensive FD-ODL implementation, employing a galvanometric scanner for group delay generation. A prototype of the low-cost FD-ODL with a 1.5 deg tilt angle, resulting in an axial scan range of 6.61 mm and an A-scan rate of 10 Hz was experimentally implemented and integrated in a dual sample beam optical low-coherence reflectometry (OLCR) setup with a detour unit to replicate the measurement window around the anterior segment and the retina. The intraocular distances of a model eye were measured with the proposed low-cost biometer and found to be in good agreement with those acquired by a custom swept-source optical coherence tomography (SS-OCT) system and two commercial biometers, validating our novel design.

5.
Appl Opt ; 61(27): 8091-8099, 2022 Sep 20.
Article in English | MEDLINE | ID: mdl-36255931

ABSTRACT

Tunable lenses (TLs) are optical devices that can change their optical power in response to an electrical signal. In many applications, they are often pushed to or beyond their temporal limits. Fast periodic and/or abrupt variations of the optical power induce undesired distortions in their transient response and produce a decrease in their performance. A low-cost focimetry system, along with a custom closed-loop iterative optimization algorithm, was developed to (1) characterize a TL's response at high speed and (2) optimize their performance in realistic TL working conditions. A significant lens performance improvement was found in about 23 iterations with a decrease in the area under the error curve and an improved effective time. Applying the closed-loop optimization algorithm in a depth scanning experiment enhanced the image quality. Quantitatively, the image quality was evaluated using the structural similarity index metric that improves in individual frames, on average, from 0.345 to 0.895.

6.
Cont Lens Anterior Eye ; 45(6): 101716, 2022 12.
Article in English | MEDLINE | ID: mdl-35606298

ABSTRACT

PURPOSE: The purpose of this study is to compare the binocular visual perception of participants wearing multifocal contact lenses and these same lens designs viewed through a temporal multiplexing visual simulator. METHODS: Visual performance and perceived visual quality at various distances were obtained in 37 participants wearing soft M-CLs and through the SimVis Gekko programmed with the same lenses. In a pilot study (n = 10) visual performance was measured in terms of LogMAR visual acuity (VA) at far (4 m), intermediate (64 cm) and near (40 cm) distances and through-focus VA (TFVA) curves with the simulated M-CLs. In the follow-up study (n = 27), LogMAR VA at far, intermediate and near distances were measured both with the actual and simulated M-CLs. Perceived visual quality was measured in both studies using the Multifocal Acceptance Score (MAS-2EV), and a Participants Reported Outcomes Vision questionnaire. Differences between the metrics obtained with simulated and actual lenses were obtained. RESULTS: Both actual and simulated M-CLs increased depth-of-focus by a similar amount. Mean LogMAR VA differences with actual and simulated M-CLs ranged between 4 and 6 letters (0.08 ± 0.01, 0.12 ± 0.01 and 0.10 ± 0.01, for far, intermediate and near distances, respectively). MAS-2EV average score differences with actual and simulated M-CLs ranged between -1.00 and + 4.25. Average MAS-2EV scores were not correlated significantly with VA. However, MAS-2EV (average and individual scores) were highly correlated to visual quality questionnaire responses (p < 0.005). CONCLUSIONS: A simultaneous vision simulator accurately represented vision with M-CLs both VA at various distances and perceived visual quality, as measured in a clinical setting. The MAS-2EV metric accurately captured participant reported outcomes of standard vision questionnaires. The combination of SimVis Gekko and MAS-2EV has the potential to largely reduce chair time in M-CLs fitting.


Subject(s)
Contact Lenses , Presbyopia , Humans , Presbyopia/therapy , Contrast Sensitivity , Follow-Up Studies , Pilot Projects , Vision, Binocular/physiology
7.
Sci Rep ; 11(1): 1397, 2021 01 14.
Article in English | MEDLINE | ID: mdl-33446794

ABSTRACT

We present a new metric (Multifocal Acceptance Score, MAS-2EV) to evaluate vision with presbyopic corrections. The MAS-2EV is based on a set of images representing natural visual scenes at day and night conditions projected in far and near displays, and a near stereo target. Subjects view and score the images through different binocular corrections (monofocal corrections at far; bifocal corrections; monovision and modified monovision) administered with soft contact lenses (in cyclopleged young subjects) or with a binocular simultaneous vision simulator (in presbyopic and cyclopleged young subjects). MAS-2EV scores are visually represented in the form of polygons, and quantified using different metrics: overall visual quality, visual degradation at far, visual benefit at near, near stereo benefit, visual imbalance near-far, overall visual imbalance and a combined overall performance metric. We have found that the MAS-2EV has sufficient repeatability and sensitivity to allow differentiation across corrections with only two repetitions, and the duration of the psychophysical task (3 min for subject/condition/correction) makes it useable in the clinic. We found that in most subjects binocular bifocal corrections produce the lowest visual imbalance, and the highest near stereo benefit. 46.67% of the subjects ranked binocular bifocal corrections first, and 46.67% of the subjects ranked monovision first. MAS-2EV, particularly in combination with visual simulators, can be applied to select prospective presbyopic corrections in patients prior to contact lens fitting or intraocular lens implantation.

8.
Transl Vis Sci Technol ; 9(10): 20, 2020 09.
Article in English | MEDLINE | ID: mdl-33005478

ABSTRACT

Purpose: As multifocal contact lenses (MCLs) expand as a solution for presbyopia correction, a better understanding of their optical and visual performance becomes essential. Also, providing subjects with the experience of multifocal vision before contact lens fitting becomes critical, both to systematically test different multifocal designs and to optimize selection in the clinic. In this study, we evaluated the ability of a simultaneous vision visual simulator (SimVis) to represent MCLs. Methods: Through focus (TF) optical and visual quality with a center-near aspheric MCL (low, medium and high near adds) were measured using a multichannel polychromatic Adaptive Optics visual simulator equipped with double-pass, SimVis (temporal multiplexing), and psychophysical channels to allow measurements on-bench and in vivo. On bench TF optical quality of SimVis-simulated MCLs was obtained from double-pass (DP) images and images of an E-stimulus using artificial eyes. Ten presbyopic subjects were fitted with the MCL. Visual acuity (VA) and DP retinal images were measured TF in a 4.00 D range with the MCL on eye, and through SimVis simulations of the same MCLs on the same subjects. Results: TF optical (on bench and in vivo) and visual (in vivo) quality measurements captured the expected broadening of the curves with increasing add. Root mean square difference between real and SimVis-simulated lens was 0.031/0.025 (low add), 0.025/0.015 (medium add), 0.019/0.011 (high add), for TF DP and TF LogMAR VA, respectively. A shape similarity metric shows high statistical values (lag κ = 0), rho = 0.811/0.895 (low add), 0.792/0.944 (medium add), and 0.861/0.915 (high add) for TF DP/LogMAR VA, respectively. Conclusions: MCLs theoretically and effectively expand the depth of focus. A novel simulator, SimVis, captured the through-focus optical and visual performance of the MCL in most of the subjects. Visual simulators allow subjects to experience vision with multifocal lenses prior to testing them on-eye. Translational Relevance: Simultaneous visual simulators allow subjects to experience multifocal vision non-invasively. We demonstrated equivalency between real multifocal contact lenses and SimVis-simulated lenses. The results suggest that SimVis is a suitable technique to aid selection of presbyopic corrections in the contactology practice.


Subject(s)
Contact Lenses , Presbyopia , Eyeglasses , Humans , Presbyopia/therapy , Vision, Ocular , Visual Acuity
9.
Opt Express ; 27(3): 2085-2100, 2019 Feb 04.
Article in English | MEDLINE | ID: mdl-30732252

ABSTRACT

Tunable lenses are becoming ubiquitous, in applications including microscopy, optical coherence tomography, computer vision, quality control, and presbyopic corrections. Many applications require an accurate control of the optical power of the lens in response to a time-dependent input waveform. We present a fast focimeter (3.8 KHz) to characterize the dynamic response of tunable lenses, which was demonstrated on different lens models. We found that the temporal response is repetitive and linear, which allowed the development of a robust compensation strategy based on the optimization of the input wave, using a linear time-invariant model. To our knowledge, this work presents the first procedure for a direct characterization of the transient response of tunable lenses and for compensation of their temporal distortions, and broadens the potential of tunable lenses also in high-speed applications.

10.
Biomed Opt Express ; 9(12): 6302-6317, 2018 Dec 01.
Article in English | MEDLINE | ID: mdl-31065430

ABSTRACT

The Simultaneous Vision simulator (SimVis) is a visual demonstrator of multifocal lens designs for prospective intraocular lens replacement surgery patients and contact lens wearers. This programmable device employs a fast tunable lens and works on the principle of temporal multiplexing. The SimVis input signal is tailored to mimic the optical quality of the multifocal lens using the theoretical SimVis temporal profile, which is evaluated from the through-focus Visual Strehl ratio metric of the multifocal lens. In this paper, for the first time, focimeter-verified on-bench validations of multifocal simulations using SimVis are presented. Two steps are identified as being critical to accurate SimVis simulations. Firstly, a new iterative approach is presented that improves the accuracy of the theoretical SimVis temporal profile for three different multifocal intraocular lens designs - diffractive trifocal, refractive segmented bifocal, and refractive extended depth of focus, while retaining a low sampling. Secondly, a fast focimeter is used to measure the step response of the tunable lens, and the input signal is corrected to include the effects of the transient behavior of the tunable lens. It was found that the root-mean-square of the difference between the estimated through-focus Visual Strehl ratio of the multifocal lens and SimVis is not greater than 0.02 for all the tested multifocal designs.

11.
Biomed Opt Express ; 8(7): 3410-3425, 2017 Jul 01.
Article in English | MEDLINE | ID: mdl-28717577

ABSTRACT

Fast tunable lenses allow an effective design of a portable simultaneous vision simulator (SimVis) of multifocal corrections. A novel method of evaluating the temporal profile of a tunable lens in simulating different multifocal intraocular lenses (M-IOLs) is presented. The proposed method involves the characteristic fitting of the through-focus (TF) optical quality of the multifocal component of a given M-IOL to a linear combination of TF optical quality of monofocal lenses viable with a tunable lens. Three different types of M-IOL designs are tested, namely: segmented refractive, diffractive and refractive extended depth of focus. The metric used for the optical evaluation of the temporal profile is the visual Strehl (VS) ratio. It is shown that the time profiles generated with the VS ratio as a metric in SimVis resulted in TF VS ratio and TF simulated images that closely matched the TF VS ratio and TF simulated images predicted with the M-IOL. The effects of temporal sampling, varying pupil size, monochromatic aberrations, longitudinal chromatic aberrations and temporal dynamics on SimVis are discussed.

12.
Biomed Opt Express ; 4(9): 1595-609, 2013.
Article in English | MEDLINE | ID: mdl-24049680

ABSTRACT

Custom high-resolution high-speed anterior segment spectral domain Optical Coherence Tomography (OCT) provided with automatic quantification and distortion correction algorithms was used to characterize three-dimensionally (3-D) the human crystalline lens in vivo in four subjects, for accommodative demands between 0 to 6 D in 1 D steps. Anterior and posterior lens radii of curvature decreased with accommodative demand at rates of 0.73 and 0.20 mm/D, resulting in an increase of the estimated optical power of the eye of 0.62 D per diopter of accommodative demand. Dynamic fluctuations in crystalline lens radii of curvature, anterior chamber depth and lens thickness were also estimated from dynamic 2-D OCT images (14 Hz), acquired during 5-s of steady fixation, for different accommodative demands. Estimates of the eye power from dynamical geometrical measurements revealed an increase of the fluctuations of the accommodative response from 0.07 D to 0.47 D between 0 and 6 D (0.044 D per D of accommodative demand). A sensitivity analysis showed that the fluctuations of accommodation were driven by dynamic changes in the lens surfaces, particularly in the posterior lens surface.

13.
Biomed Opt Express ; 3(10): 2471-88, 2012 Oct 01.
Article in English | MEDLINE | ID: mdl-23082289

ABSTRACT

Custom high-resolution high-speed anterior segment spectral domain optical coherence tomography (OCT) was used to characterize three-dimensionally (3-D) the human crystalline lens in vivo. The system was provided with custom algorithms for denoising and segmentation of the images, as well as for fan (scanning) and optical (refraction) distortion correction, to provide fully quantitative images of the anterior and posterior crystalline lens surfaces. The method was tested on an artificial eye with known surfaces geometry and on a human lens in vitro, and demonstrated on three human lenses in vivo. Not correcting for distortion overestimated the anterior lens radius by 25% and the posterior lens radius by more than 65%. In vivo lens surfaces were fitted by biconicoids and Zernike polynomials after distortion correction. The anterior lens radii of curvature ranged from 10.27 to 14.14 mm, and the posterior lens radii of curvature ranged from 6.12 to 7.54 mm. Surface asphericities ranged from -0.04 to -1.96. The lens surfaces were well fitted by quadrics (with variation smaller than 2%, for 5-mm pupils), with low amounts of high order terms. Surface lens astigmatism was significant, with the anterior lens typically showing horizontal astigmatism ([Formula: see text] ranging from -11 to -1 µm) and the posterior lens showing vertical astigmatism ([Formula: see text] ranging from 6 to 10 µm).

14.
Optom Vis Sci ; 89(5): E709-18, 2012 May.
Article in English | MEDLINE | ID: mdl-22466105

ABSTRACT

PURPOSE: To propose a method to correct optical coherence tomography (OCT) images of posterior surface of the crystalline lens incorporating its gradient index (GRIN) distribution and explore its possibilities for posterior surface shape reconstruction in comparison to existing methods of correction. METHODS: Two-dimensional images of nine human lenses were obtained with a time-domain OCT system. The shape of the posterior lens surface was corrected using the proposed iterative correction method. The parameters defining the GRIN distribution used for the correction were taken from a previous publication. The results of correction were evaluated relative to the nominal surface shape (accessible in vitro) and compared with the performance of two other existing methods (simple division, refraction correction: assuming a homogeneous index). Comparisons were made in terms of posterior surface radius, conic constant, root mean square, peak to valley, and lens thickness shifts from the nominal data. RESULTS: Differences in the retrieved radius and conic constant were not statistically significant across methods. However, GRIN distortion correction with optimal shape GRIN parameters provided more accurate estimates of the posterior lens surface in terms of root mean square and peak values, with errors <6 and 13 µm, respectively, on average. Thickness was also more accurately estimated with the new method, with a mean discrepancy of 8 µm. CONCLUSIONS: The posterior surface of the crystalline lens and lens thickness can be accurately reconstructed from OCT images, with the accuracy improving with an accurate model of the GRIN distribution. The algorithm can be used to improve quantitative knowledge of the crystalline lens from OCT imaging in vivo. Although the improvements over other methods are modest in two dimension, it is expected that three-dimensional imaging will fully exploit the potential of the technique. The method will also benefit from increasing experimental data of GRIN distribution in the lens of larger populations.


Subject(s)
Algorithms , Imaging, Three-Dimensional , Lens, Crystalline/anatomy & histology , Tomography, Optical Coherence/methods , Accommodation, Ocular , Adolescent , Adult , Aged , Cadaver , Child , Female , Humans , Lens, Crystalline/physiology , Male , Middle Aged , Refraction, Ocular , Reproducibility of Results , Young Adult
15.
Opt Express ; 18(21): 21905-17, 2010 Oct 11.
Article in English | MEDLINE | ID: mdl-20941090

ABSTRACT

We present an optimization method to retrieve the gradient index (GRIN) distribution of the in-vitro crystalline lens from optical path difference data extracted from OCT images. Three-dimensional OCT images of the crystalline lens are obtained in two orientations (with the anterior surface up and posterior surface up), allowing to obtain the lens geometry. The GRIN reconstruction method is based on a genetic algorithm that searches for the parameters of a 4-variable GRIN model that best fits the distorted posterior surface of the lens. Computer simulations showed that, for noise of 5 µm in the surface elevations, the GRIN is recovered with an accuracy of 0.003 and 0.010 in the refractive indices of the nucleus and surface of the lens, respectively. The method was applied to retrieve three-dimensionally the GRIN of a porcine crystalline lens in vitro. We found a refractive index ranging from 1.362 in the surface to 1.443 in the nucleus of the lens, an axial exponential decay of the GRIN profile of 2.62 and a meridional exponential decay ranging from 3.56 to 5.18. The effect of GRIN on the aberrations of the lens also studied. The estimated spherical aberration of the measured porcine lens was 2.87 µm assuming a homogenous equivalent refractive index, and the presence of GRIN shifted the spherical aberration toward negative values (-0.97 µm), for a 6-mm pupil.


Subject(s)
Lens, Crystalline/pathology , Tomography, Optical Coherence/methods , Adult , Algorithms , Animals , Computer Simulation , Crossing Over, Genetic , Crystallization , Humans , Lens, Crystalline/anatomy & histology , Middle Aged , Models, Genetic , Mutation , Refraction, Ocular , Refractometry , Swine
16.
Vision Res ; 50(19): 2008-14, 2010 Sep 15.
Article in English | MEDLINE | ID: mdl-20659497

ABSTRACT

We demonstrate that certain combinations of non-rotationally symmetric aberrations (coma and astigmatism) can improve retinal image quality over the condition with the same amount of astigmatism alone. Simulations of the retinal image quality in terms of Strehl Ratio, and measurements of Visual Acuity under controlled aberrations with adaptive optics were performed, varying defocus, astigmatism and coma. Astigmatism ranged between 0 and 1.5D. Defocus ranged typically between -1 and 1D. The amount of coma producing best retinal image quality (for a given relative angle between astigmatism and coma) was computed and the amount was found to be different from zero in all cases (except for 0D of astigmatism). For example, for a 6mm pupil, in the presence of 0.5D of astigmatism, a value of coma of 0.23mum produced (for best focus) a peak improvement in Strehl Ratio by a factor of 1.7, over having 0.5D of astigmatism alone. The improvement holds over a range of >1.5D of defocus and peak improvements were found for amounts of coma ranging from 0.15mum to 0.35mum. We measured VA under corrected high order aberrations, astigmatism alone (0.5D) and astigmatism in combination with coma (0.23mum), with and without adaptive optics correction of all the other aberrations, in two subjects. We found that the combination of coma with astigmatism improved decimal VA by a factor of 1.28 (28%) and 1.47 (47%) in both subjects, over VA with astigmatism alone when all the rest of aberrations were corrected. Nevertheless, in the presence of typical normal levels of HOA the effect of the coma/astigmatism interaction is considerably diminished.


Subject(s)
Adaptation, Ocular/physiology , Astigmatism/physiopathology , Retina/physiopathology , Visual Acuity/physiology , Adult , Humans
17.
Vision Res ; 50(19): 1922-7, 2010 Sep 15.
Article in English | MEDLINE | ID: mdl-20600230

ABSTRACT

High order aberrations have been suggested to play a role in determining the direction of accommodation. We have explored the effect of retinal blur induced by high order aberrations on dynamic accommodation by measuring the accommodative response to sinusoidal variations in accommodative demand (1-3D). The targets were blurred with 0.3 and 1mum (for a 3-mm pupil) of defocus, coma, trefoil and spherical aberration. Accommodative gain decreased significantly when 1-mum of aberration was induced. We found a strong correlation between the relative accommodative gain (and phase lag) and the contrast degradation imposed on the target at relevant spatial frequencies.


Subject(s)
Accommodation, Ocular/physiology , Adaptation, Physiological/physiology , Astigmatism/physiopathology , Adult , Analysis of Variance , Humans , Young Adult
18.
J Vis ; 10(5): 19, 2010 May 01.
Article in English | MEDLINE | ID: mdl-20616133

ABSTRACT

We measured the effect of the correction of the natural aberrations of the eye by means of adaptive optics on the subject's performance on three different visual tasks: subjective sharpness assessment of natural images, familiar face recognition, and facial expression recognition. Images were presented through a dedicated psychophysical channel and viewed through an electromagnetic deformable mirror. Experiments were performed on 17 normal subjects. Ocular aberrations (astigmatism and higher order aberrations) were reduced on average from 0.366 +/- 0.154 to 0.101 +/- 0.055 mum for a 5-mm pupil diameter. On average, subjects considered to be sharper 84 +/- 14% of the images viewed under AO correction, and there was a significant correlation between the amount of corrected aberrations and the percentage of images that the subject considered sharper when observed under AO-corrected aberrations. In all eyes (except one), AO correction improved familiar face recognition, by a factor of x1.13 +/- 0.12 on average. However, AO correction did not improve systematically facial expression recognition.


Subject(s)
Adaptation, Physiological/physiology , Astigmatism/physiopathology , Astigmatism/rehabilitation , Visual Perception/physiology , Adult , Eyeglasses , Humans , ROC Curve , Task Performance and Analysis , Young Adult
19.
J Vis ; 9(6): 4.1-15, 2009 Jun 09.
Article in English | MEDLINE | ID: mdl-19761295

ABSTRACT

We evaluated the accommodative response to a stimulus moving from 0 to 6 D following a staircase function under natural, corrected, and induced optical aberrations, using an adaptive-optics (AO) electromagnetic deformable mirror. The accommodative response of the eye (through the mirror) and the change of aberrations were measured on 5 subjects using a Hartmann-Shack wavefront sensor operating at 12.8 Hz. Five conditions were tested: (1) natural aberrations, (2) AO correction of the unaccommodated state and induction (over 6-mm pupils) of (3) +1 microm and (4) -1 microm of spherical aberration and (5) -2 microm of vertical coma. Four subjects showed a better accommodative response with AO correction than with their natural aberrations. The induction of negative spherical aberration also produced a better accommodative response in the same subjects. Accommodative lag increased in all subjects when positive spherical aberration and coma were induced. Fluctuations of the accommodative response (computed during each 1-D period of steady accommodation) increased with accommodative response when high-order aberrations were induced. The largest fluctuations occurred for induced negative spherical aberration and the smallest for natural and corrected aberrations. The study demonstrates that aberrations influence accommodative lag and fluctuations of accommodation and that correcting aberrations improves rather than compromises the accommodative response.


Subject(s)
Aberrometry , Accommodation, Ocular/physiology , Electromagnetic Phenomena , Motion Perception/physiology , Ocular Physiological Phenomena , Optical Devices , Adult , Humans , Photic Stimulation/methods , Reaction Time , Refraction, Ocular , Young Adult
20.
J Vis ; 8(13): 1.1-12, 2008 Oct 06.
Article in English | MEDLINE | ID: mdl-19146331

ABSTRACT

We evaluated the visual benefit of correcting astigmatism and high-order aberrations with adaptive optics (AO) on visual acuity (VA) measured at 7 different luminances (ranging from 0.8 to 50 cd/m(2)) and two contrast polarities (black letters on white background, BoW, and white letters on black background, WoB) on 7 subjects. For the BoW condition, VA increased with background luminance in both natural and AO-corrected conditions, and there was a benefit of AO correction at all luminances (by a factor of 1.29 on average across luminances). For WoB VA increased with foreground luminance but decreased for the highest luminances. In this reversed polarity condition AO correction increased VA by a factor of 1.13 on average and did not produce a visual benefit at high luminances. The improvement of VA (averaged across conditions) was significantly correlated (p = 0.04) with the amount of corrected aberrations (in terms of Strehl ratio). The improved performance with WoB targets with respect to BoW targets is decreased when correcting aberrations, suggesting a role of ocular aberrations in the differences in visual performance between contrast polarities.


Subject(s)
Astigmatism/physiopathology , Astigmatism/rehabilitation , Contrast Sensitivity , Light , Optical Devices , Refractive Errors/physiopathology , Refractive Errors/rehabilitation , Visual Acuity , Accommodation, Ocular , Adult , Convergence, Ocular , Equipment Design , Humans