Article in Chinese | MEDLINE | ID: mdl-25322611

ABSTRACT

OBJECTIVE: Explore the model of universal NICU newborns' hearing screening in high-risk neonates, preliminary understanding factor of hearing damage. METHOD: Transient evoked otoacoustic emissions (TEOAE) and automatic auditory brainstem response (AABR) were used to detect newborns' hearing in 13 315 objects, that is newborns' hearing screening in NICU with TEOAE test who not pass, 42 days after will use AABR rescreening. Children's Hearing Center of Guangxi Child Health Hospital will diagnose the newborns that did not pass in 3 months. RESULT: In these 13 315 newborns, 5 151 subjects who did not pass the initial screening, 1910 subjects who also did not pass after 42 days, 1167 subjects cannot pass the rescreening after 3 months, 642 subjects were diagnosed congenital hearing impairment by Brainstem Auditory Evoked Potential Test, the rate is 4.82%. CONCLUSION: TEOAE and AABR are the suitable model of universal newborns' hearing screening in high-risk neonates.


Subject(s)
Hearing Tests , Neonatal Screening , Evoked Potentials, Auditory, Brain Stem , Female , Follow-Up Studies , Humans , Infant, Newborn , Intensive Care Units, Neonatal , Male