1.
J Med Phys ; 48(2): 175-180, 2023.
Article in English | MEDLINE | ID: mdl-37576088

ABSTRACT

Purpose: The study is intended to perform an end-to-end test of the entire intraoperative process using cadaver heads. A simulation of tumor removal was performed, followed by irradiation of the bed and measurement of absorbed doses with radiochromic films. Materials and Methods: Low-energy X-ray intraoperative radiotherapy (IORT) was used for irradiation. A computed tomography study was performed at each site and the absorbed doses calculated by the treatment planning system, as well as absorbed doses with radiochromic films, were studied. Results: The absorbed doses in the organs at risk (OAR) were evaluated in each case, obtaining maximum doses within the tolerance limits. The absorbed doses in the target were verified and the deviations were <1%. Conclusions: These tests demonstrated that this comprehensive procedure is a reproducible quality assurance tool which allows continuous assessment of the dosimetric and geometric accuracy of clinical brain IORT treatments. Furthermore, the absorbed doses measured in both target and OAR are optimal for these treatments.

2.
Phys Med ; 112: 102622, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37331081

ABSTRACT

PURPOSE: This study presents a treatment planning system for intraoperative low-energy photon radiotherapy based on photogrammetry from real images of the surgical site taken in the operating room. MATERIAL AND METHODS: The study population comprised 15 patients with soft-tissue sarcoma. The system obtains the images of the area to be irradiated with a smartphone or tablet, so that the absorbed doses in the tissue can be calculated from the reconstruction without the need for computed tomography. The system was commissioned using 3D printing of the reconstructions of the tumor beds. The absorbed doses at various points were verified using radiochromic films that were suitably calibrated for the corresponding energy and beam quality. RESULTS: The average reconstruction time of the 3D model from the video sequence in the 15 patients was 229,6±7,0 s. The entire procedure, including video capture, reconstruction, planning, and dose calculation was 520,6±39,9 s. Absorbed doses were measured on the 3D printed model with radiochromic film, the differences between these measurements and those calculated by the treatment planning system were 1.4% at the applicator surface, 2.6% at 1 cm, 3.9% at 2 cm and 6.2% at 3 cm. CONCLUSIONS: The study shows a photogrammetry-based low-energy photon IORT planning system, capable of obtaining real-time images inside the operating room, immediately after removal of the tumor and immediately before irradiation. The system was commissioned with radiochromic films measurements in 3D-printed model.


Subject(s)
Brachytherapy , Sarcoma , Humans , Radiotherapy Dosage , Brachytherapy/methods , Radiotherapy Planning, Computer-Assisted/methods , Phantoms, Imaging , Photogrammetry
3.
Brachytherapy ; 21(4): 389-396, 2022.
Article in English | MEDLINE | ID: mdl-35246391

ABSTRACT

INTRODUCTION: This study analyzes cases in which electronic brachytherapy (eBT) led to acceptable treatment plans in cervical cancer. Findings were compared with dosimetry values obtained in 192Ir-based treatments according to the high-risk clinical target volume (HR-CTV) and the disease stage. MATERIAL AND METHODS: We retrospectively analyzed 48 patients with cervical cancer from two centers. The patients were treated with 192Ir based on MRI. It was possible to use interstitial needles via an Utrecht-type applicator. Dosimetry was simulated using eBT and the parameters D90 and D98 (HR-CTV) and D2cc, D1cc, and D0.1cc (bladder, rectum, and sigmoid colon) were evaluated. The Mann-Whitney U test was used for comparison. The overall cohort of patients was analyzed, as were the sub-cohorts based on stage (FIGO stages I+IIA, IIB and III-IV). Finally, the dosimetry of the eBT plans was evaluated, and the plans obtained were classified as "good", "acceptable", or "poor". RESULTS: Statistically significant differences were found between the eBT and 192Ir plans for D98 (HR-CTV), D1cc and D0.1cc (bladder), and D1cc and D0.1cc (sigmoid colon). A total of 31 cases (64.6%) were considered good, seven (14.6%) were considered acceptable, and 10 (20.8%) were considered poor. For volumes <30 cc, all the plans were good or acceptable; for volumes >30 cc, 54.3% were good, and 71.4% were good or acceptable. By stage, eBT plans for patients with stage IB-IIA disease were good in 100%, whereas those for patients with stage IIB were good in 70.6% and III-IV disease were good in 50%. CONCLUSIONS: eBT provides appropriate dosimetry for treatment of cervical cancer in selected cases.


Subject(s)
Brachytherapy , Uterine Cervical Neoplasms , Brachytherapy/methods , Electronics , Feasibility Studies , Female , Humans , Organs at Risk , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Retrospective Studies , Tomography, X-Ray Computed/methods , Uterine Cervical Neoplasms/radiotherapy
4.
J Appl Clin Med Phys ; 20(7): 78-86, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31183970

ABSTRACT

PURPOSE: We report the first cervical cancer cases treated with interstitial electronic brachytherapy (eBT) at our hospital and compare them with plans made with high-dose-rate interstitial brachytherapy based on Ir192 (HDR-BT). MATERIALS AND METHODS: Eight patients with cervical cancer were treated with the Axxent eBT device (Xoft, Inc.). Planning was with magnetic resonance imaging and computed tomography following the recommendations of the EMBRACE protocol. The dosimetry parameters of organs at risk (OAR) were evaluated for the bladder, rectum, and sigmoid colon (D2cc, D1cc, and D0.1cc). In addition, the V150 and V200 of irradiated tissue were compared for both eBT and HDR-BT. All patients received intensity-modulated external beam radiation therapy with a regimen of 23 sessions of 2 Gy followed by four sessions of 7 Gy of eBT performed over 2 weeks (two sessions followed by another two sessions a week later) following the EMBRACE recommendations. Each of the eight patients was followed to assess acute toxicity associated with treatment. RESULTS: The doses reaching OAR for eBT plans were lower than for HDR-BT plans. As for acute toxicity associated with eBT, very few cases of mucositis were detected. No cases of rectal toxicity and one case with grade 1 urinary toxicity were detected. The results at 1 month are equally good, and no relapses have occurred to date. CONCLUSIONS: The first results of treatment with the Axxent eBT device are promising, as no recurrences have been observed and toxicity is very low. eBT is a good alternative for treating cervical cancer in centers without access to conventional HDR.


Subject(s)
Brachytherapy/methods , Electrons/therapeutic use , Neoplasm Recurrence, Local/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Uterine Cervical Neoplasms/radiotherapy , Adult , Aged , Female , Humans , Middle Aged , Organs at Risk/radiation effects , Prognosis , Radiotherapy Dosage , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...