Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 53
Filter
1.
Article in English | MEDLINE | ID: mdl-38764290

ABSTRACT

BACKGROUND: The randomized DIRECTAVI trial demonstrated safety and feasibility of transcatheter aortic valve implantation (TAVI) without balloon aortic valvuloplasty (BAV) using SAPIEN 3 balloon-expandable devices. However, the female population with smaller anatomy may have potential higher risk of residual gradient and/or mismatch. PURPOSE: We assessed the impact of BAV on the procedural success rate and clinical outcomes in the female population of the DIRECTAVI trial. METHODS: Between May 2016 and May 2018, 91 of the 250 patients included in the DIRECTAVI trial were women (38.6%), 45 of them (49.5%) were enrolled in the BAV group and 46 of them (50.5%) in the direct TAVI group. The primary endpoint was procedural success rate in women (Valve Academic Research Consortium-2 criteria). The secondary endpoint included evaluation of PPM and 1-month major adverse events according to the implantation stategy in women and comparison between men and women regarding major endpoints. RESULTS: The primary endpoint occurred in 29 women (64.4%) in the BAV group and in 34 women (73.9%) in the direct TAVI group (mean difference 9.47%; 95% confidence interval: 6.5%-25.4%; p = 0.045 for non-inferiority of the direct strategy). One-month major adverse events were similar between the 2 women groups. Procedural success was lower in women vs men (p = 0.01) due to higher incidence of moderate mismatches in women (p = 0.001) but with no significant difference regarding the implantation strategy (p = 0.4). CONCLUSION: Direct implantation of the balloon-expandable SAPIEN 3 valve was non-inferior to predilatation on procedural success in women. Incidence of moderate mismatch was higher in women but was not related to the implantation strategy.

2.
J Surg Res ; 295: 222-230, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38039727

ABSTRACT

INTRODUCTION: Study aims were to evaluate the elastic properties of vascular substitutes frequently used for pulmonary artery (PA) replacement, and then to compare their compliance and stiffness indexes to those of human PA. METHODS: A bench-test pulsatile flow experiment was developed to perfuse human cadaveric vascular substitutes (PA, thoracic aorta, human pericardial conduit), bovine pericardial conduit, and prosthetic vascular substitutes (polytetrafluorethylene and Dacron grafts) at a flow and low pulsed pressure mimicking pulmonary circulation. Intraluminal pressure was measured. An ultrasound system with an echo-tracking function was used to monitor vessel wall movements. The diameter, compliance, and stiffness index were calculated for each vascular substitute and compared to the human PA at mean pressures ranging from 10 to 50 mmHg. RESULTS: The compliance of the PA and the thoracic aorta were similar at mean physiological pressures of 10 mmHg and 20 mmHg. The PA was significantly less compliant than the aorta at mean pressures above 30 mmHg (P = 0.017). However, there was no difference in stiffness index between the two substitutes over the entire pressure range. Compared to the PA, human pericardial conduit was less compliant at 10 mmHg (P = 0.033) and stiffer at 10 mmHg (P = 0.00038) and 20 mmHg (P = 0.026). Bovine pericardial conduit and synthetic prostheses were significantly less compliant and stiffer than the PA for mean pressures of 10, 20, and 30 mmHg. There were no differences at 40 and 50 mmHg. CONCLUSIONS: Allogenic arterial grafts appear to be the most suitable vascular substitutes in terms of compliance and stiffness for PA replacement.


Subject(s)
Pulmonary Artery , Humans , Animals , Cattle , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/surgery , Ultrasonography , Pulsatile Flow
3.
J Endovasc Ther ; : 15266028231206996, 2023 Oct 23.
Article in English | MEDLINE | ID: mdl-37872769

ABSTRACT

PURPOSE: For aortic coarctation in adults endovascular repair is the treatment of choice with an acceptable safety profile. Aortic isthmus atresia is a related condition with a complete occlusion of the aorta not allowing catheterization across the isthmus. This technical note describes a recanalization of an aortic isthmus atresia using radiofrequency with an "electrified wire technique." TECHNIQUE: A guidewire was selectively denuded of PTFE (polytetrafluoroethylene) at the distal end and was placed through a catheter distal to the aortic isthmus atresia. The denuded end of the wire was clamped to an electrosurgery pencil. By pushing the wire toward a tulip-snare, which was placed as a target proximal of the occlusion via left trans-brachial access, and shortly activating of the electrosurgery pencil the electrified wire recanalized the occlusion and was snared and used to guide implantation of a balloon-expandable covered stent. CONCLUSION: The electrified wire puncture technique can be used to recanalize adult aortic isthmus atresia after failed conventional attempts. CLINICAL IMPACT: The electrified wire technique offers an off-the shelf option to modify standard guidewires for the use with radiofrequency to cross a complete aortic isthmus occlusion after failed conventional attempts. This new technique may be applied also in other situations like dissection flap fenestration, transcaval access and similar.

4.
J Endovasc Ther ; : 15266028221116747, 2022 Aug 04.
Article in English | MEDLINE | ID: mdl-35927926

ABSTRACT

OBJECTIVE: The aim was to evaluate early and medium-term outcomes of double fenestrated physician-modified endovascular grafts for total endovascular aortic arch repair. METHODS: This single-center retrospective analysis of prospectively-collected data included 100 patients, from January 2017 to December 2021, undergoing thoracic endovascular aortic repair (TEVAR) for zone 0. The fenestrations were a proximal larger fenestration that incorporated the brach2iocephalic trunk and left common carotid artery and a distal smaller fenestration for the left subclavian artery (LSA). Only the LSA fenestration was stented. RESULTS: The median duration for stent-graft modification was 23±6 minutes. Of the 100 patients, 70 were men. The mean patient age was 70±10.5 years. Indications for treatment included degenerative aortic arch aneurysm (n=32), dissecting aortic arch aneurysm after type A dissections (n=23) and (n=19) after type B dissections, acute complicated type B dissection (n=16), and other pathologies (n=10). Technical success rate was 97%. The 30 day mortality was 2% (n=2). Four patients (4%) had minor stroke with full recovery. One patient (1%) had a type IA endoleak, 1 patient (1%) had a type IB endoleak, and 2 patients (2%) have a type II endoleak from the LSA. Eight patients (8%) required reintervention: 1 type IA endoleak, 1 type IB endoleak, 1 retrograde type A dissection, and 5 because of access-related complications. During a mean follow-up of 24±7.2 months, there were no aortic rupture, paraplegia, and all supra-aortic trunks were patent. CONCLUSIONS: Double homemade fenestrated TEVAR is both feasible and effective for total endovascular aortic arch repair avoiding the need for anatomical and extra-anatomical surgical revascularization. The long-term durability will need to be assessed in studies with long-term follow-up. CLINICAL IMPACT: Double homemade fenestrated TEVAR is effective for total endovascular aortic arch repair avoiding the need for anatomical and extra-anatomical surgical revascularization. The standout feature of this double fenestrated device is its simple handling during operation with the proximal fenestrations being directed to the orifices of the BT and LCCA automatically when the LSA fenestration is catheterized and secured by covered stent placement. The deployment algorithm actively steers the operator away from superfluous manipulations of the device within the arch and avoids guidewire manipulation in carotid arteries. The long-term durability will need to be assessed in studies with long-term follow-up.

5.
J Vasc Surg ; 76(5): 1133-1140.e2, 2022 11.
Article in English | MEDLINE | ID: mdl-35697312

ABSTRACT

OBJECTIVE: We evaluated the early- and medium-term outcomes of single- and double-fenestrated physician-modified endovascular grafts (PMEGs) for total endovascular degenerative aortic arch aneurysm repair. METHODS: We performed a single-center, retrospective analysis of prospectively collected data from 52 patients from August 2013 through January 2021 who had undergone homemade fenestrated thoracic endovascular aortic repair for degenerative aortic aneurysms. In all cases, a distal smaller fenestration for the left subclavian artery (LSA) was fashioned and was the only one stented. For a double-fenestrated endograft, a proximal larger fenestration that incorporated both the brachiocephalic trunk and the left common carotid artery was added. RESULTS: A total of 52 patients with degenerative aortic arch aneurysms were treated. Of the 52 patients, 36 were men, the mean age was 75 ± 8 years, 31% had received a single LSA fenestration, and 69% had undergone double-fenestrated thoracic endovascular aortic repair. Of the 52 procedures, 5 (10%) were emergent procedures. The technical success was 100%. The median time required for stent graft modification was 22 ± 6 minutes. The 30-day mortality was 2% (n = 1). Five patients (10%) had experienced a cerebrovascular event, including two transient ischemic attacks, one minor stroke with full neurologic recovery, and two with sequelae. Two patients (4%) had experienced perioperative retrograde dissection during follow-up. No patient had developed a type I, II, or III endoleak from the LSA. No patient had required reintervention. All supra-aortic trunks were patent. During a mean follow-up of 18 ± 11 months, no patient had required conversion to open surgical repair, aortic rupture, or paraplegia. CONCLUSIONS: Single or double PMEG is a safe and suitable tool for the treatment of high morbidity pathology such as aortic arch degenerative aneurysm repair. In addition, this device can be used in patients requiring elective or emergency repair.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Aneurysm , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Physicians , Male , Humans , Aged , Aged, 80 and over , Female , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/etiology , Aortic Dissection/surgery , Endovascular Procedures/adverse effects , Retrospective Studies , Prosthesis Design , Treatment Outcome , Postoperative Complications/therapy , Risk Factors , Time Factors , Stents/adverse effects , Aortic Aneurysm/surgery
6.
Catheter Cardiovasc Interv ; 100(2): 235-242, 2022 08.
Article in English | MEDLINE | ID: mdl-35661552

ABSTRACT

BACKGROUND: Bridging of vitamin K antagonist (VKA) with heparin is usually not promoted during interventional or surgical procedures related to increased risk of bleeding and thrombotic events but this strategy has not been evaluated during transcatheter aortic valve implantation (TAVI). PURPOSE: The aim of this study was to evaluate the rate of major bleeding and vascular complications after TAVI performed in patients with uninterrupted VKA. METHODS: From January 2016 to October 2017, consecutive patients who underwent TAVI with uninterrupted VKA (International Normalized Ratio [INR] between 1.5 and 3.5) were prospectively included in a monocentric registry. TAVI was performed according to current guidelines and a 50 U/kg bolus of heparin was injected at the beginning of the procedure for all patients. Vascular and bleeding complications were assessed using the Valve Academic Research Consortium 3 (VARC3) and the Bleeding Academic Research Consortium (BARC) definitions at a 30-day follow-up. RESULTS: A total of 88 patients were included with a median age of 84 years (81.8-87.0), 42% being female. The median society of thoracic surgeons score was 5.1 (4.1-7.5), the median CHADS2-VASc was 5.5 (5-6) and 60.2% had a chronic kidney failure. Median INR at the time of implantation was 2.1 (1.8-2.6). The main VKA indication was atrial fibrillation. Transfemoral access was used in 88.6% of the patients. Major bleeding (BARC ≥ 3b) occurred in five patients (5.7%) and major vascular complications occurred in seven patients (8.0%). At 1 month follow-up, major bleeding (BARC ≥ 3) or vascular complications occurred in 10 patients (11.4%). In patients with major bleeding peripheral arterial disease (RR = 10.95; 95% confidence interval (CI) 1.63-73.75; p = 0.014) and carotid access (RR = 8.56; 95% CI 1.19-1.51; p = 0.033) were more common. INR > 2.5 was significantly associated with vascular complications (RR = 7.14; 95% CI 1.29-39.63; p = 0.025). At 30 days, mortality and stroke rates were 2.3% and 4.5%, respectively. CONCLUSION: TAVI with uninterrupted VKA treatment seems feasible and safe with a low risk of major bleeding and vascular complications in this first single-center experience. Particular caution is advocated in high body mass index patients and to keep INR < 2.5.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Anticoagulants/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Female , Fibrinolytic Agents , Hemorrhage/chemically induced , Heparin , Humans , Male , Treatment Outcome , Vitamin K
7.
J Clin Med ; 11(10)2022 May 16.
Article in English | MEDLINE | ID: mdl-35628919

ABSTRACT

Increasing operators' experience and improvement of the technique have resulted in a drastic reduction in complications following transcatheter aortic valve replacement (TAVR) in patients with lower surgical risk. In parallel, the procedure was considerably simplified, with a routine default approach including local anesthesia in the catheterization laboratory, percutaneous femoral approach, radial artery as the secondary access, prosthesis implantation without predilatation, left ventricle wire pacing and early discharge. Thus, the "simplified" TAVR adopted in most centers nowadays is a real revolution of the technique. However, simplified TAVR must be accompanied upstream by a rigorous selection of patients who can benefit from a minimalist procedure in order to guarantee its safety. The minimalist strategy must not become dogmatic and careful pre-, per- and post-procedural evaluation of patients with well-defined protocols guarantee optimal care following TAVR. This review aims to evaluate the benefits and limits of the simplified TAVR procedure in a current and future vision.

8.
Int J Cardiol ; 353: 29-34, 2022 Apr 15.
Article in English | MEDLINE | ID: mdl-35065152

ABSTRACT

BACKGROUND: Right ventricular (RV) dysfunction and tricuspid regurgitation (TR) may impact prognosis of patients undergoing Transcatheter Aortic Valve Implantation (TAVI). We aimed to evaluate the evolution of previous RV dysfunction and/or significant TR after TAVI procedure. METHODS: All patients undergoing TAVI between January 2018 and January 2019 were enrolled in this prospective cohort. Patients with at least one right heart (RH) abnormality at baseline including RV dysfunction (TAPSE < 17 mm, S-wave < 9.5 cm/s, Fractional area change < 35%, Strain > -20%, Tei > 0.54) and/or significant TR (Effective Regurgitant Orifice Area ≥ 40 mm2 and/or Regurgitant Volume ≥ 45 mL) underwent transthoracic echocardiography at day 1 and 6-month after TAVI. The primary endpoint was the regression of pre-TAVI RV dysfunction and/or significant TR at 6-month follow-up. RESULTS: The study enrolled 144 patients including 76 women (52.8%) with a mean age of 81.1 ± 6.8 yo, a mean EuroSCORE 2 of 5.2 ± 3.9%. At least one RH abnormality was observed in 53 patients (36.8%). At 6-month, at least one RV dysfunction parameter significantly improved in 26 patients (63.4%), TAPSE increasing from 13.0 ± 2.6 to 16.0 ± 9.8 mm, p < 0.0001 and S-wave from 7.7 ± 1.2 to 10.0 ± 2.6 cm/s, p = 0.004. Among 31 patients with baseline significant TR, TR decreased in 14 (45.2%); p = 0.003. Among patients with baseline RH abnormalities, 13 (24.5%) fully recovered. Baseline significant TR was predictive of 6-month clinical outcomes (OR = 3.1, 95%CI = [1.01-9.0], p = 0.03). CONCLUSION: In our recent intermediate surgical risk TAVI population, RV dysfunction and/or significant TR are frequent at baseline and fully or partially recover in most patients at 6-month follow-up.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Tricuspid Valve Insufficiency , Ventricular Dysfunction, Right , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Female , Humans , Prospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/epidemiology , Tricuspid Valve Insufficiency/surgery , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Dysfunction, Right/epidemiology , Ventricular Dysfunction, Right/etiology , Ventricular Function, Right
9.
J Endovasc Ther ; 29(5): 697-704, 2022 10.
Article in English | MEDLINE | ID: mdl-34852653

ABSTRACT

PURPOSE: To describe the use of physician-modified endograft (PMEG) with the exclusive use of inner branches or in combination with fenestrations for the urgent treatment of complex aortic aneurysms. TECHNIQUE: We present two urgent cases. A patient with a 6.8 cm saccular juxtarenal aneurysm and another patient with a contained rupture of the thoracoabdominal aorta right above the celiac trunk (CT). In both cases, a Cook Zenith TX2 thoracic endograft was back-table modified, in the first case by adding three fenestrations and one inner branch for the left renal artery to improve sealing due to its partial involvement in the aneurysm and, in the second case, with the use of two inner branches for the CT and superior mesenteric artery. Both procedures were successful, with uneventful postoperative courses and complete aneurysm exclusion on postoperative CT angiography. CONCLUSION: Use of PMEGs with inner branches is feasible for urgent repair in complex aortic anatomy.


Subject(s)
Aortic Aneurysm, Abdominal , Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Physicians , Aorta/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/methods , Endovascular Procedures/adverse effects , Humans , Postoperative Complications/therapy , Prosthesis Design , Time Factors , Treatment Outcome
10.
J Endovasc Ther ; 29(3): 402-408, 2022 06.
Article in English | MEDLINE | ID: mdl-34711093

ABSTRACT

PURPOSE: The purpose of this article is to study 1-year results of Zenith branch iliac endovascular graft (ZBIS) with the off-label use of a 13 mm spiral Z limb to connect to the aortic main body. MATERIALS AND METHODS: A retrospective review from 2015 to 2019 of all iliac branch devices (IBDs) was performed at 1 institution that were connected to an aortic main body with a 13 mm spiral Z limb and had at least 1-year follow-up with computed tomography (CT). Primary endpoints are freedom from ZBIS separation from the connection limb, endoleak (EL), or reintervention at 1 year. Secondary endpoints are primary and secondary ZBIS patency, presence of any EL, and aortic reinterventions. RESULTS: Of 149 IBDs implanted in this period, 45 ZBIS in 35 patients were connected with a 13 mm limb and had a 1-year CT; 97% of patients had common iliac artery (CIA) aneurysms, 7% of patients had hypogastric artery (HA) aneurysms, and 30% of patients had bilateral ZBIS implantation. Technical success was 98%. In 84% of cases, the Advanta V12 was used as the HA mating stent; 56% of patients had an EL, mostly type II, which resolved spontaneously in 70% at 1 year, and 9% of ZBIS required reinterventions at 1 year (2 for thrombosis, 2 for type Ic EL from HA mating stent). One-year ZBIS primary patency and secondary patency were 96% and 100%, respectively. No EL was noted to be related to the 13 mm connection limb. No migration or separation of the devices occurred. CONCLUSIONS: The use of 13 mm spiral Z limb to connect a ZBIS with the main body in our series yields a high technical success rate and good 12-month outcomes without device separation or migration.


Subject(s)
Blood Vessel Prosthesis Implantation , Endovascular Procedures , Iliac Aneurysm , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/therapy , Endovascular Procedures/adverse effects , Humans , Iliac Aneurysm/surgery , Off-Label Use , Prosthesis Design , Retrospective Studies , Risk Factors , Stents , Treatment Outcome
11.
J Endovasc Ther ; 29(4): 555-564, 2022 08.
Article in English | MEDLINE | ID: mdl-34781755

ABSTRACT

PURPOSE: The purpose of this study was to evaluate early and mid-term results of non-standard management of the supraaortic target vessels with the use of the inner branch arch endograft in a single high-volume center. MATERIAL AND METHODS: A single-center retrospective study including all patients undergoing implantation of an inner branch arch endograft from December 2012 to March 2021, who presented a non-standard management of the supraaortic target vessels (any bypass other than a left carotid-subclavian or landing in a dissected target vessel). Technical success, mortality, reinterventions, endoleak (EL), and aortic remodeling at follow-up were analyzed. RESULTS: Twenty-four patients were included. In 17 (71%) cases, the non-standard management was related to innominate artery (IA) compromise (12 with IA dissection, 2 with short IA, 2 with short proximal aortic landing zone that required occlusion of IA, 1 with occluded IA after open arch repair). Two (8%) cases were related to an aberrant right subclavian artery (RSA), 1 patient (4%) due to the concomitant presence of a left vertebral artery (LVA) arising from the arch and an occluded left subclavian artery (LSA), and another patient presented with an occluded LSA distal to a dominant vertebral artery. Three (13%) cases were exclusively related to management in patients with genetic aortic syndromes. Twenty (83%) patients had a previous type A aortic dissection. Ten (42%) patients presented a thoracic or thoracoabdominal aortic aneurysm and 8 (33%) patients an arch aneurysm, 6 of them associated to false lumen (FL) perfusion. There were 2 (8%) perioperative minor strokes, and 1 patient with perioperative mortality. Seven patients presented an early type I endoleak, all resolved at follow-up. Seven patients required reinterventions during follow-up (7 reinterventions related to continuous false lumen perfusion, 3 related to Type Ia endoleak, 2 related to surgical bypass). All patients who presented with FL perfusion had complete FL thrombosis at follow-up. No patient presented aneurysm growth at follow-up. CONCLUSIONS: The use of the inner branch arch endograft with a non-standard management of the supraaortic target vessels is a possible option. Despite a high reintervention rate, regression or stability of the aneurysmal diameter was achieved in all the patients with follow-up.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aortic Dissection/surgery , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/therapy , Humans , Retrospective Studies , Time Factors , Treatment Outcome
12.
J Endovasc Ther ; 29(5): 711-716, 2022 10.
Article in English | MEDLINE | ID: mdl-34964371

ABSTRACT

PURPOSE: The concept of a single endovascular valve-carrying conduit device was designated endo-Bentall, but published experience is limited to a single case. This technical note describes an alternative modular endo-Bentall technique and a novel access technique to implant it. TECHNIQUE: A 82-year-old woman with chest pain referred for a 10 cm symptomatic aneurysm of the distal arch and descending aorta. An ascending aortic aneurysm of 5.5 cm prevented endovascular aortic arch repair due to lack of a proximal landing zone. The technique is a modular approach combining a physician-modified endograft (PMEG) with 3 large fenestrations for coronary artery perfusion and a transcatheter aortic valve implantation (TAVI). A "rendez-vous access" with a transapical and transfemoral through-and-through wire offered rapid sequential deployment in a modular fashion of both components. The PMEG was deployed first, landing 5 mm deep in the left ventricular outflow tract (LVOT) and the transcatheter aortic valve was implanted few millimeters below. The endo-Bentall procedure was combined with endovascular aortic arch repair. CONCLUSION: A modular endo-Bentall procedure combining a PMEG and TAVI is feasible and adaptable to emergent setting using the "rendez-vous access."


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aged, 80 and over , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Female , Humans , Treatment Outcome
14.
Interact Cardiovasc Thorac Surg ; 32(6): 942-949, 2021 05 27.
Article in English | MEDLINE | ID: mdl-34047348

ABSTRACT

OBJECTIVES: The critical step in total endovascular aortic arch repair is to ensure alignment of fenestrations with, and thus maintenance of flow to, supra-aortic trunks. This experimental study evaluates the feasibility and accuracy of a double-fenestrated physician-modified endovascular graft [single common large fenestration for the brachiocephalic trunk and left common carotid artery and a distal small fenestration for left subclavian artery (LSA) with a preloaded guidewire for the LSA] for total endovascular aortic arch repair. METHODS: Eight fresh human cadaveric thoracic aortas were harvested. Thoracic endografts with a physician-modified double fenestration were deployed for total endovascular aortic arch repair in a bench test model. A guidewire was preloaded through the distal fenestration for the LSA. All experiments were undertaken in a hybrid room under fluoroscopic guidance with subsequent angioscopy and open evaluation for assessment. RESULTS: Mean aortic diameter in zone 0 was 31.3 ± 3.33 mm. Mean duration for stent graft modification was 20.1 ± 5.8 min. Mean duration of the procedure was 24 ± 8.6 min. The Medtronic Valiant Captivia stent graft was used in 6 and the Cook Alpha Zenith thoracic stent graft in 2 cases. LSA catheterization was technically successful with supra-aortic trunk patency in 100% of cases. CONCLUSIONS: The use of a double-fenestrated stent graft with a preloaded guidewire appears to be a useful technical addition to facilitate easy and correct alignment of stent graft fenestrations with supra-aortic trunk origins.


Subject(s)
Aorta, Thoracic , Blood Vessel Prosthesis Implantation , Stents , Aortic Dissection/surgery , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Endovascular Procedures , Humans , Physicians , Prosthesis Design , Treatment Outcome
15.
J Endovasc Ther ; 28(5): 676-681, 2021 10.
Article in English | MEDLINE | ID: mdl-34032470

ABSTRACT

PURPOSE: Endovascular repair of chronic thoracoabdominal aortic dissection with aneurysmal degeneration presents a therapeutic challenge when one or more visceral branches arise from the false lumen without an adjacent reentry. The chronic dissection flap can be thick and resistant to flap fenestration with standard techniques. TECHNIQUE: The powered cheese wire technique facilitates cutting of a dissection flap using electrical current on a noninsulated through-and-through wire segment. The mid-shaft of the guidewire is denuded and kinked to form the "flying V" configuration. This solution is based on the BASILICA procedure, which uses electrosurgery to split aortic valve tissue lengthwise prior to transcatheter aortic valve replacement to prevent coronary artery obstruction. We demonstrate the technique in a case of branched endovascular aortic repair of a complex thoracoabdominal dissecting aneurysm in which a renal artery from the false lumen was catheterized by creating a powered cheese wire fenestration. CONCLUSION: The powered cheese wire technique is an effective approach to access false lumen originating branches during endovascular aortic repair of chronic aortic dissections.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Fluoroscopy , Humans , Treatment Outcome
16.
Int J Cardiol ; 330: 158-163, 2021 05 01.
Article in English | MEDLINE | ID: mdl-33621627

ABSTRACT

BACKGROUND: Telemetry monitoring (TM) with or without intensive care unit (ICU) admission is the standard of care after Transcatheter aortic valve replacement (TAVR). Regarding to improvements of the technique and procedural results, TM may be considered only in selected patients. We aimed to confirm feasibility and safety of selective TM in patients undergoing TAVR. METHODS: We prospectively evaluated 449 consecutive patients undergoing TAVR. Patients were transferred to general cardiology ward (GCW) without TM after the procedure when stable clinical state, transfemoral access, no baseline right bundle branch block (RBBB), left ventricular ejection fraction (LVEF) > 40%, and no complication including any electrocardiogram (ECG) change within 1 h after the procedure ("low-risk" group). Others patients were considered for TM in ICU ("high-risk" group). The primary endpoint evaluated in-hospital major adverse events after unit admission according to VARC-2 criteria. RESULTS: The mean age was 81.8 ± 7.5 years and mean EuroSCORE II was 7.5 ± 4.8%. In total, 116 patients (25.8%) were considered as "low-risk" patients and 163 patients (36.3%) were referred to GCW, including those with immediate pacemaker implantation. A total of 96 patients (21.3%) reached the primary endpoint including mainly conductive disorders (12.8%). No major adverse events, particularly no late severe conductive disorder, occurred in the "low-risk" group (negative predictive value of 100%). Baseline RBBB (p < 0.01), LVEF < 40% (p = 0.02) and "high-risk" group (p < 0.01) were predictive of outcomes. CONCLUSIONS: Using rigorous periprocedural selection criteria, patients' admission in GCW without TM can be routinely and safely performed in 1/3 of patients after TAVR.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Prospective Studies , Risk Factors , Stroke Volume , Telemetry , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Ventricular Function, Left
17.
Catheter Cardiovasc Interv ; 97(7): 1452-1459, 2021 06 01.
Article in English | MEDLINE | ID: mdl-33325639

ABSTRACT

AIMS: While major vascular complications (MVC) remains an issue after Transfemoral (TF) transcatheter aortic valve replacement (TAVR), we compared outcomes in TF versus transcarotid (TC) approaches in patients with complex vascular anatomy. METHODS AND RESULTS: Among patients undergoing TAVR in our center between 2015 and 2018, we evaluated patients with complex vascular anatomy defined on CT scan as: (a) iliofemoral diameter between 5.5 and 6 mm or <6.5 mm with severe calcifications or tortuosity AND/OR (b) abdominal aorta pathology. The primary endpoint included access failure, mortality, MVC, major bleeding and stroke at 1-month. Among 483 patients, 131 (31.2%) with complex vascular anatomy underwent TF (n = 51;39.2%) or TC (n = 80;60.8%) TAVR. The mean age was 81.7 ± 6.9. TC group had higher STS score (p = .01), higher incidence of coronary artery disease (p = .04) and lower left ventricular ejection fraction (p < .001). In TC group, primary endpoint occurred twice less without reaching significance compared to TF group (n = 8; 10.0% vs. n = 10; 19.6% respectively; p = .1). Incidence of MVC was higher in TF group (11.8 vs. 1.3% in the TC group; p = .01) with similar incidence of stroke between groups (p = .8). CONCLUSIONS: Despite higher patient risk profile, TC approach in complex aortofemoral anatomy provides similar favorable outcomes with less MVC compared to TF approach.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Humans , Retrospective Studies , Risk Assessment , Risk Factors , Stroke Volume , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Ventricular Function, Left
18.
J Vasc Surg ; 73(6): 1898-1905.e1, 2021 06.
Article in English | MEDLINE | ID: mdl-33227376

ABSTRACT

OBJECTIVE: Our aim was to evaluate the early- and medium-term outcomes of using double fenestrated physician-modified endovascular grafts (PMEGs) for total endovascular aortic arch repair. METHODS: The present single-center retrospective analysis of prospectively collected data included 50 patients from January 2017 through October 2019, who had undergone thoracic endovascular aortic repair (TEVAR). The fenestrations were a proximal larger fenestration that incorporated the brachiocephalic trunk and left common carotid artery and a distal smaller fenestration for the left subclavian artery (LSA). Only the LSA fenestration was stented. RESULTS: The median duration for stent graft modification was 26 ± 6 minutes. Of the 50 patients, 41 were men. The mean patient age was 68 ± 11.5 years. The indications for treatment included degenerative aortic arch aneurysm (n = 17), dissecting aortic arch aneurysm after type A dissection (n = 13), type B dissection (n = 13), aortic ulcer (n = 3), and other pathologies (n = 4). The technical success rate was 94% (47 of 50) overall, and 100% (28 of 28) after a technical modification incorporating a preloaded guide wire for the LSA fenestration (P < .05). The 30-day mortality was 2% (n = 1). Two patients (4%) had a minor stroke with full recovery. One patient (2%) had a type IB and two patients (4%) had a type II endoleak from the LSA. Four patients (8%) required reintervention: one because of a type IB endoleak and three because of access-related complications. All supra-aortic trunks were patent. During a mean follow-up of 16 ± 8.3 months, no conversions to open surgical repair were required and no aortic rupture, paraplegia, or retrograde dissection occurred. CONCLUSIONS: Using double fenestrated PMEGs for TEVAR is both feasible and effective for total endovascular aortic arch repair, avoiding the need for anatomic and extra-anatomic surgical revascularization. The absence of brachiocephalic trunk stenting was not associated with endoleaks or treatment failure and resulted in a lower stroke risk than alternative strategies. The midterm results suggest that stenting of the brachiocephalic trunk and right common carotid artery might not be necessary for a large proportion of patients undergoing total endovascular aortic arch repair. The persistence of the seal and ongoing durability require assessment in studies with long-term follow-up data available.


Subject(s)
Aorta, Thoracic/surgery , Aortic Diseases/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Stents , Adult , Aged , Aged, 80 and over , Aortic Dissection/diagnostic imaging , Aortic Dissection/mortality , Aortic Dissection/surgery , Aorta, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/mortality , Aortic Aneurysm, Thoracic/surgery , Aortic Diseases/diagnostic imaging , Aortic Diseases/mortality , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Female , Humans , Male , Middle Aged , Prosthesis Design , Registries , Retrospective Studies , Time Factors , Treatment Outcome , Ulcer/diagnostic imaging , Ulcer/mortality , Ulcer/surgery
19.
J Am Heart Assoc ; 9(24): e018405, 2020 12 15.
Article in English | MEDLINE | ID: mdl-33297821

ABSTRACT

Background Myocardial injury is associated with higher mortality after transcatheter aortic valve replacement (TAVR) and might be increased by prior balloon aortic valvuloplasty (BAV). We aimed to evaluate the impact of prior BAV versus direct prosthesis implantation on myocardial injury occurring after (TAVR) with balloon-expandable prostheses. Methods and Results The DIRECTAVI (Direct Transcatheter Aortic Valve Implantation) trial, an open-label randomized study, demonstrated noninferiority of TAVR without BAV (direct TAVR group) compared with systematic BAV (BAV group) with the Edwards SAPIEN 3 valve. High-sensitivity troponin was assessed before and the day after the procedure. Incidence of myocardial injury after the procedure (high-sensitivity troponin elevation >15× the upper reference limit [14 ng/L]) was the main end point. Impact of myocardial injury on 1-month adverse events (all-cause mortality, stroke, major bleeding, major vascular complications, transfusion, acute kidney injury, heart failure, pacemaker implantation, and aortic regurgitation) was evaluated. Preprocedure and postprocedure high-sensitivity troponin levels were available in 211 patients. The mean age of patients was 83 years (78-87 years), with 129 men (61.1%). Mean postprocedure high-sensitivity troponin was 124.9±81.4 ng/L in the direct TAVR group versus 170.4±127.7 ng/L in the BAV group (P=0.007). Myocardial injury occurred in 42 patients (19.9%), including 13 patients (12.2%) in the direct TAVR group and 29 (27.9%) in the BAV group (P=0.004). BAV increased by 2.8-fold (95% CI, 1.4-5.8) myocardial injury probability. Myocardial injury was associated with 1-month adverse events (P=0.03). Conclusions BAV increased the incidence and magnitude of myocardial injury after TAVR with new-generation balloon-expandable valves. Myocardial injury was associated with 1-month adverse events. These results argue in favor of direct SAPIEN 3 valve implantation. Registration URL: https://www.Clinicaltrials.gov; Unique identifier: NCT02729519.


Subject(s)
Aortic Valve Disease/surgery , Aortic Valve Insufficiency/etiology , Balloon Valvuloplasty/adverse effects , Myocardium/metabolism , Transcatheter Aortic Valve Replacement/adverse effects , Aged , Aged, 80 and over , Aortic Valve Insufficiency/epidemiology , Female , Heart Valve Prosthesis Implantation/adverse effects , Humans , Male , Postoperative Complications/epidemiology , Postoperative Complications/metabolism , Postoperative Complications/mortality , Prognosis , Prospective Studies , Prosthesis Design , Troponin/blood
20.
Pan Afr Med J ; 37: 65, 2020.
Article in English | MEDLINE | ID: mdl-33244328

ABSTRACT

Rupture of Valsalva sinus remains a very rare and deadly complication of Valsalva sinus aneurysm with a high mortality rate. We report here the case of a 47-year-old man who presented to the emergency department with acute exercise-induced dyspnea, chest pain, and fever. Transthoracic (TTE) and transesophageal echocardiography (TEE) highlighted a rupture of the right Valsalva sinus in the right atrium due to infective endocarditis. After stabilization of the patient, a successful surgical repair with double pericardial patches was performed.


Subject(s)
Aortic Rupture/etiology , Endocarditis/complications , Sinus of Valsalva/diagnostic imaging , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/etiology , Aortic Rupture/diagnostic imaging , Chest Pain/etiology , Echocardiography , Echocardiography, Transesophageal , Heart Atria/diagnostic imaging , Humans , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...