Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Zhonghua Nan Ke Xue ; 25(5): 444-450, 2019 May.
Article in Chinese | MEDLINE | ID: mdl-32216232

ABSTRACT

OBJECTIVE: To comprehensively evaluate the clinical effect, safety and cost of Qianlieshutong Capsules (QC) in the treatment of chronic prostatitis. METHODS: We searched Cochrane Library, PubMed, Springer, ProQuest, CNKI, Wanfang Data and VIP for randomized controlled trials (RCT) on the treatment of chorionic prostatitis with QC published from January 2000 to May 2018. According to the inclusion and exclusion criteria, two researchers independently completed the screening and evaluation of the articles, extraction of information, and meta-analysis of the included RCTs using the RevMan 5.3 software. RESULTS: Totally 10 RCTs involving 1 796 cases were included in this study, in which the chronic prostatitis patients treated by the combination of QC and quinolones all showed a significantly better response than the controls (P < 0.05). QC combined with quinolones cost an average of ¥23 more than quinolones alone with a 1% increase of therapeutic effectiveness, ¥38.39 more with a 1-unit reduction of WBCs, and ¥38.84 more with a 1-point decrease in the NIH-CPSI score. CONCLUSIONS: The combination of QC with quinolones has a better therapeutic efficacy but a higher cost than quinolones alone in the treatment of chronic prostatitis.


Subject(s)
Drugs, Chinese Herbal/economics , Drugs, Chinese Herbal/therapeutic use , Prostatitis/drug therapy , Capsules , Chronic Disease , Humans , Male , Prostatitis/economics , Quinolones/therapeutic use , Randomized Controlled Trials as Topic
2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 34(8): 2203-7, 2014 Aug.
Article in Chinese | MEDLINE | ID: mdl-25474962

ABSTRACT

The present paper performed the evaluation of four dark-object subtraction(DOS) atmospheric correction methods based on 2012 Inner Mongolia experimental data The authors analyzed the impacts of key parameters of four DOS methods when they were applied to ZY-3 CCD data The results showed that (1) All four DOS methods have significant atmospheric correction effect at band 1, 2 and 3. But as for band 4, the atmospheric correction effect of DOS4 is the best while DOS2 is the worst; both DOS1 and DOS3 has no obvious atmospheric correction effect. (2) The relative error (RE) of DOS1 atmospheric correction method is larger than 10% at four bands; The atmospheric correction effect of DOS2 works the best at band 1(AE (absolute error)=0.0019 and RE=4.32%) and the worst error appears at band 4(AE=0.0464 and RE=19.12%); The RE of DOS3 is about 10% for all bands. (3) The AE of atmospheric correction results for DOS4 method is less than 0. 02 and the RE is less than 10% for all bands. Therefore, the DOS4 method provides the best accuracy of atmospheric correction results for ZY-3 image.

3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(2): 343-8, 2012 Feb.
Article in Chinese | MEDLINE | ID: mdl-22512165

ABSTRACT

The accuracy of the calibration coefficients of the ground-based thermal-infrared radiometer CE312 is one of the most important factors affecting the calibration of the thermal-infrared remote sensors. The theory of two calibration methods which calculate the bandpass radiance and spectral radiance respectively is introduced. The calibration of the CE312-1b is conducted with the blackbody in the laboratory, the accuracy and influence factors of the results are conducted by the MODIS data combined with in situ measurements data at Qinghai Lake in Aug 2010. The results show that calibration coefficients of thermal-infrared field radiometer CE312 calculated by the bandpass radiance method has better performance in the accuracy and applicability than the spectral radiance method.

4.
Guang Pu Xue Yu Guang Pu Fen Xi ; 30(11): 3149-55, 2010 Nov.
Article in Chinese | MEDLINE | ID: mdl-21284203

ABSTRACT

Hyper spectrum imager (HSI) loaded on HJ-1A satellite is Chinese first spaceborne hyperspectrum sensor. Since the HSI has no spectrum response function of all channels, the usually used calibration method-reflectance based method has been modified, and a new calibration method is proposed, in which the spectrum response function is neglected. Based on the calibration experiment data of Dunhuang in Aug., 2009, the HSI sensor was calibrated on orbit. The different kinds of spectrum response were constructed based on the formula, and the errors of calibration results with different spectrum response function were analyzed. The results show, expecting for the channels of water vapor and oxygen absorption channel, the influence of spectrum response function in other channel is less than 3%, and the calibration result based on new calibration method can satisfy the application requirement.

SELECTION OF CITATIONS
SEARCH DETAIL
...